Excretion in humans – IGCSE Biology (0610)
1 question · Clear filters
Question text
1
You are going to investigate osmosis. You will be using a model cell made from dialysis tubing.
Dialysis tubing is permeable to water but not permeable to larger molecules such as sucrose,
which is a type of sugar.
Read all the instructions but DO NOT CARRY THEM OUT until you have drawn a table for
your results in the space provided in 1(a)(i).
You should use the safety equipment provided while you are carrying out the practical work.
Label one test-tube DW and the other S. Place both test-tubes in the test-tube rack.
Step 1
Fill the syringe with 10 cm 3 of sucrose solution.
Step 2
Step 3
Remove one knotted piece of dialysis tubing from the container. Open the unknotted
end by rubbing it gently between your fingers. Carefully transfer the 10 cm 3 of sucrose
solution from the syringe into the dialysis tubing bag.
Step 4
Hold the top of the dialysis tubing bag containing the sucrose solution as shown in
Fig. 1.1. Use the ruler to measure the distance from the knot to the meniscus of the liquid
in the bag.
Think about how you will ensure that this measurement can be made consistently.
Record this measurement in your table in 1(a)(i).
finger
dialysis tubing bag
measure
bottom of the meniscus
from the knot to
the meniscus
knot
Fig. 1.1
Place the dialysis tubing bag into the test-tube labelled S. Fold the open end of the bag
Step 5
over the top of the test-tube and secure with an elastic band, as shown in Fig. 1.2.
elastic band
open end of the
dialysis tubing bag
test-tube
Fig. 1.2
Fill the syringe with 10 cm 3 of distilled water.
Step 6
Step 7
Remove the second knotted piece of dialysis tubing from the container. Open the
unknotted end by rubbing it gently between your fingers. Carefully transfer the 10 cm 3 of
distilled water from the syringe into the dialysis tubing bag.
Step 8
Repeat steps 4 and 5 with the dialysis tubing bag containing the distilled water and the
test-tube labelled DW.
Record the measurement for distilled water in your table in 1(a)(i).
Use the measuring cylinder to measure 30 cm 3 of distilled water. Pour the distilled water
Step 9
into test-tube S, as shown in Fig. 1.3.
elastic band
open end of the
dialysis tubing bag
test-tube
30 cm 3 of distilled water
Fig. 1.3
Step 10 Repeat step 9 for test-tube DW.
Step 11 Place test-tubes S and DW into the empty 250 cm 3 beaker. Raise your hand when you
are ready for 200 cm 3 of hot water to be added to the beaker to make a hot water-bath.
Step 12 Start the stop-clock and leave the test-tubes in the hot water-bath for 15 minutes.
Continue with the other questions while you are waiting.
Step 13 After 15 minutes remove test-tubes S and DW from the hot water-bath and place them in
the test-tube rack.
Step 14 Carefully remove the dialysis tubing bag from test-tube S. Hold the top of the bag and
use the ruler to measure the distance from the knot to the meniscus of the liquid in the
bag. Ensure that your measurement starts from the same place as the measurement
made in step 4.
Record this measurement in your table in 1(a)(i).
Step 15 Repeat step 14 with test-tube DW.
(a) (i)
Prepare a table to record your results.
[4]
(ii)
Calculate the change in distance from the knot to the meniscus of the solution in the
dialysis tubing bag in test-tubes S and DW.
S … mm
DW … mm
[1]
(iii)
Explain why it was important to take the measurements in step 4 and step 14 from the
same place on the dialysis tubing.
…
…
… [1]
(iv)
St