Biology (0610) · Feb/March 2021 · Question paper 52

Cambridge Biology (0610) question paper for paper 52, Feb/March 2021 — 0610/52/F/M/21, file 0610_m21_qp_52.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

Cambridge IGCSE™

* 2 8 9 2 0 0 5 0 6 4 *

BIOLOGY

0610/52
February/March 2021

Paper 5 Practical Test

1 hour 15 minutes
You must answer on the question paper.
You will need:

The materials and apparatus listed in the confidential instructions

INSTRUCTIONS
●
Answer all questions.
●
Use a black or dark blue pen. You may use an HB pencil for any diagrams or graphs.
●
Write your name, centre number and candidate number in the boxes at the top of the page.
●
Write your answer to each question in the space provided.
●
Do not use an erasable pen or correction fluid.
●
Do not write on any bar codes.
●
You may use a calculator.
●
You should show all your working and use appropriate units.

INFORMATION
●
The total mark for this paper is 40.
●
The number of marks for each question or part question is shown in brackets [ ].

For Examiner’s Use
1
2
Total

This document has 12 pages.
DC (CJ/CB) 203209/4
© UCLES 2021

[Turn over

www.dynamicpapers.com

2
1

You are going to investigate osmosis. You will be using a model cell made from dialysis tubing.
Dialysis tubing is permeable to water but not permeable to larger molecules such as sucrose,
which is a type of sugar.
Read all the instructions but DO NOT CARRY THEM OUT until you have drawn a table for
your results in the space provided in 1(a)(i).
You should use the safety equipment provided while you are carrying out the practical work.
Step 1

Label one test-tube DW and the other S. Place both test-tubes in the test-tube rack.

Step 2

Fill the syringe with 10 cm3 of sucrose solution.

Step 3

Remove one knotted piece of dialysis tubing from the container. Open the unknotted
end by rubbing it gently between your fingers. Carefully transfer the 10 cm3 of sucrose
solution from the syringe into the dialysis tubing bag.

Step 4

Hold the top of the dialysis tubing bag containing the sucrose solution as shown in
Fig. 1.1. Use the ruler to measure the distance from the knot to the meniscus of the liquid
in the bag.
Think about how you will ensure that this measurement can be made consistently.
Record this measurement in your table in 1(a)(i).

finger

dialysis tubing bag
measure
from the knot to
the meniscus

bottom of the meniscus

knot

Fig. 1.1

© UCLES 2021

0610/52/F/M/21

3
Step 5

www.dynamicpapers.com

Place the dialysis tubing bag into the test-tube labelled S. Fold the open end of the bag
over the top of the test-tube and secure with an elastic band, as shown in Fig. 1.2.
elastic band
open end of the
dialysis tubing bag

test-tube

Fig. 1.2
Step 6

Fill the syringe with 10 cm3 of distilled water.

Step 7

Remove the second knotted piece of dialysis tubing from the container. Open the
unknotted end by rubbing it gently between your fingers. Carefully transfer the 10 cm3 of
distilled water from the syringe into the dialysis tubing bag.

Step 8

Repeat steps 4 and 5 with the dialysis tubing bag containing the distilled water and the
test-tube labelled DW.
Record the measurement for distilled water in your table in 1(a)(i).

Step 9

Use the measuring cylinder to measure 30 cm3 of distilled water. Pour the distilled water
into test-tube S, as shown in Fig. 1.3.
elastic band
open end of the
dialysis tubing bag
test-tube
30 cm3 of distilled water

Fig. 1.3
Step 10 Repeat step 9 for test-tube DW.
Step 11 Place test-tubes S and DW into the empty 250 cm3 beaker. Raise your hand when you
are ready for 200 cm3 of hot water to be added to the beaker to make a hot water-bath.

© UCLES 2021

0610/52/F/M/21

[Turn over

www.dynamicpapers.com

4

Step 12 Start the stop-clock and leave the test-tubes in the hot water-bath for 15 minutes.
Continue with the other questions while you are waiting.
Step 13 After 15 minutes remove test-tubes S and DW from the hot water-bath and place them in
the test-tube rack.
Step 14 Carefully remove the dialysis tubing bag from test-tube S. Hold the top of the bag and
use the ruler to measure the distance from the knot to the meniscus of the liquid in the
bag. Ensure that your measurement starts from the same place as the measurement
made in step 4.
Record this measurement in your table in 1(a)(i).
Step 15 Repeat step 14 with test-tube DW.
(a) (i)

Prepare a table to record your results.

[4]
(ii)

Calculate the change in distance from the knot to the meniscus of the solution in the
dialysis tubing bag in test-tubes S and DW.

S mm
DW mm
[1]
© UCLES 2021

0610/52/F/M/21

5
(iii)

www.dynamicpapers.com

Explain why it was important to take the measurements in step 4 and step 14 from the
same place on the dialysis tubing.

[1]

(iv)

State a conclusion for the results of this investigation.

[1]

(v)

Identify the variable that was measured (dependent variable) in this investigation.
[1]

(b) (i)

One syringe was used for both step 2 and step 6. This is a source of error.
Explain why this was a source of error and how this could have affected the results.
error

effect on the results

[2]

(ii)

Only one set of results was collected during this investigation.
Explain why it is better to collect several sets of results.

[1]

© UCLES 2021

0610/52/F/M/21

[Turn over

6

www.dynamicpapers.com

(c) Students investigated the effect of sucrose concentration on the mass of potato cylinders.

•
•
•
•
•
•

A potato was cut into cylinders.
The potato cylinders were all cut to 2 cm in length.
The initial mass of each potato cylinder was measured and recorded.
Each potato cylinder was put into a different concentration of sucrose solution.
The potato cylinders were left in the sucrose solutions for one hour.
The potato cylinders were removed from the sucrose solutions and the final mass of
each potato cylinder was measured and recorded.

(i)

State two variables that were kept constant in this investigation.
1
2
[2]
The results of the investigation are shown in Table 1.1.
Table 1.1

concentration
of sucrose
/ mol per dm3

initial mass of
potato cylinder
/g

final mass of
potato cylinder
/g

0.00

2.13

2.29

0.16

7.5

0.20

2.05

2.08

0.03

1.5

0.40

2.52

2.42

–0.10

–4.0

0.60

1.68

1.52

–0.16

–9.5

0.80

1.56

1.32

–0.24

–15.4

1.00

2.51

2.08

–0.43

(ii)

change in
mass / g

percentage
change in
mass

Calculate the percentage change in mass of the potato cylinder that was immersed in
1.00 mol per dm3 sucrose solution.
Give your answer to one decimal place.
Space for working.

%
[3]

© UCLES 2021

0610/52/F/M/21

7
(iii)

www.dynamicpapers.com

Plot a line graph on the grid of the concentration of sucrose solution against the
percentage change in mass. One axis has been started for you.
Include a curved line of best fit on your graph.

0.0

[4]
(iv)

Estimate the concentration of sucrose solution at which there was no percentage change
in the mass of the potato cylinder.
mol per dm3 [1]

(v)

Explain why the percentage change in mass is more useful than the change in mass
when analysing the results in Table 1.1.

[1]

© UCLES 2021

0610/52/F/M/21

[Turn over

8

www.dynamicpapers.com

(d) State the name of the solution that is used to test for the presence of starch and give the
result of a positive test.
test solution
positive result
[2]
[Total: 24]

© UCLES 2021

0610/52/F/M/21

9
2

www.dynamicpapers.com

Fig. 2.1 is a photograph of a tomato fruit that has been cut in half.

Fig. 2.1
(a) (i)

Draw a large diagram of the tomato fruit shown in Fig. 2.1.

[4]
© UCLES 2021

0610/52/F/M/21

[Turn over

10
(ii)

www.dynamicpapers.com

Describe how you could show that a tomato fruit contains vitamin C.

[3]

© UCLES 2021

0610/52/F/M/21

11

www.dynamicpapers.com

(b) Fig. 2.2 is a photomicrograph of a tomato seed.

Q

P

magnification ×50
Fig. 2.2
Measure the length of line PQ on Fig. 2.2.
length of PQ mm
Calculate the actual size of the tomato seed using the formula and your measurement.
magnification =

length of line PQ
actual length of the tomato seed

Include the unit.
Space for working.

[3]

© UCLES 2021

0610/52/F/M/21

[Turn over

12

www.dynamicpapers.com

(c) Plan an investigation to determine the optimum (best) temperature for germination of tomato
seeds.

[6]
[Total: 16]

Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of the University of
Cambridge Local Examinations Syndicate (UCLES), which itself is a department of the University of Cambridge.

© UCLES 2021

0610/52/F/M/21

Advertisement