1
9702/41/M/J/26 · Question 8May/June 2026Paper 4113 marks
Loading question…
Question text

8
(a) State what is meant by a photon.
…
…
… [2]
(b) X-rays for use in medical diagnosis are produced by accelerating charged particles towards
a metal target.
(i)
State the name of the charged particles.
… [1]
(ii)
Describe how X-rays are formed at the target.
…
…
… [2]
(iii)
For any given accelerating voltage, there is a range of wavelengths of X-rays produced
that has a minimum value.
Explain, with reference to photons, why there is a range of wavelengths and why this
range has a minimum value.
…
…
…
…
… [3]
(iv)
Calculate the minimum wavelength of X-rays produced when the accelerating voltage
is 52.0 kV.
minimum wavelength = … m [3]
© Cambridge University Press & Assessment 2026
,

,
(c) X-rays are used to create an image of the internal structure of an object that is made from
two types of material of similar thickness.
Describe and explain how a property of the materials determines whether or not the image
produced has good contrast.
…
…
…
… [2]
[Total: 13]
© Cambridge University Press & Assessment 2026

2
9702/44/M/J/26 · Question 9May/June 2026Paper 448 marks
Loading question…
Question text

9
(a) Explain how ultrasound waves are generated by a piezoelectric transducer.
…
…
…
…
… [3]
(b) Ultrasound waves are used to obtain information about a structure that consists of two
materials, as shown in Figure 9.1.
material X
ultrasound waves
P
Q
material Y
not to scale
Figure 9.1
The waves enter the structure at point P and travel through the structure to point Q.
Material Y has a density of 8960 kg m –3 . The speed of sound in material Y is 4720 m s –1 .
(i)
Calculate the specific acoustic impedance Z of material Y. Give a unit with your answer.
Z = … unit … [2]
© Cambridge University Press & Assessment 2026
,
,
(ii)
The intensity of ultrasound entering the structure at point P is I 0 .
The transmitted intensity of the ultrasound between P and Q at distance x from P is I.
Figure 9.2 shows the variation with x of the value of ln (I / I 0 ).
0
0
2
4
6
8
10
12
x / cm
–10
In (I / I 0 )
–20
–30
– 40
Figure 9.2
Determine three conclusions about the structure and the materials from which it is
made that may be drawn from Figure 9.2. The conclusions may be qualitative or
quantitative. Use the space for any working.
1 …
…
2 …
…
3 …
…
[3]
[Total: 8]
© Cambridge University Press & Assessment 2026

3
9702/44/M/J/25 · Question 10May/June 2025Paper 449 marks
Loading question…
Question text

10 (a) Describe how the piezoelectric crystal in a transducer generates ultrasound waves for use in
medical diagnosis.
…
…
…
…
… [3]
(b) A parallel ultrasound beam is incident on the boundary between two media, as illustrated
in Fig. 10.1.
ultrasound
beam
specific acoustic
specific acoustic
impedance Z 2
impedance Z 1
Fig. 10.1
The media have specific acoustic impedances Z 1 and Z 2 .
At the boundary, a fraction α of the incident intensity of the ultrasound beam is reflected. The
remainder is transmitted.
(i)
State what is meant by specific acoustic impedance.
…
…
… [2]
Describe how α depends on the relative values of Z 1 and Z 2 .
(ii)
…
…
…
… [2]
ĬÍĊ¾Ġ´íÈõÏĪÅĊÞú·Ą×
,
,
(c) A parallel ultrasound beam of intensity I 0 enters a region of soft tissue. After passing a
distance of 2.1 cm through this tissue, the intensity of the ultrasound is 0.62 I 0 .
Calculate the linear attenuation coefficient μ of ultrasound in the soft tissue. Give a unit with
your answer.

μ = … unit … [2]
[Total: 9]
ĬÏĊ¾Ġ´íÈõÏĪÅĊÞü·Ą×

Advertisement
4
9702/41/M/J/24 · Question 8May/June 2024Paper 4113 marks
Loading question…
Question text

8
(a) State what is meant by a photon.
…
…
… [2]
(b) Fig. 8.1 shows a tube in which X-rays are produced at a metal target.
X
Y
particles
filament
vacuum
glass tube
metal target
Fig. 8.1
Particles are accelerated from the filament to the target by a constant high voltage applied
across the terminals X and Y.
(i)
State the name of the particles.
… [1]
(ii)
On Fig. 8.1, use + and – signs to label terminals X and Y to indicate the polarity of the
high voltage.
[1]
(c) For an accelerating voltage of 32 kV in Fig. 8.1, determine:
(i)
the maximum energy, in MeV, of an X-ray photon produced at the target
maximum photon energy = … MeV [1]
(ii)
the maximum momentum of an X-ray photon produced at the target
maximum photon momentum = … N s [2]
(iii)
the minimum wavelength of X-rays produced at the target.
minimum wavelength = … m [3]
(d) Explain why X-rays can be used to produce images of internal body structures that have
good contrast.
…
…
…
…
… [3]
[Total: 13]

5
9702/42/M/J/24 · Question 10May/June 2024Paper 427 marks
Loading question…
Question text

10 (a) Describe how reflected ultrasound pulses may be used to obtain diagnostic information about
internal structures.
…
…
…
… [2]
(b) (i)
Define specific acoustic impedance of a medium.
…
…
… [2]
(ii)
Table 10.1 shows some data for water and for glass.
Table 10.1
density / kg m –3
speed of sound / m s –1
water
1000
1420
glass
2500
4560
Determine the intensity reflection coefficient for ultrasound that is incident on a
water–glass boundary.
intensity reflection coefficient = … [3]
[Total: 7]
,
,
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge

6
9702/41/M/J/23 · Question 8May/June 2023Paper 418 marks
Loading question…
Question text

8
(a) Table 8.1 shows some data relating to the properties of air, gel and body tissue. The data are
given to three significant figures.
Table 8.1
specific acoustic
density / kg m –3
speed of sound / m s –1
material
impedance / kg m –2 s –1
air
340
440
gel
1200
1400
1.68 × 10 6
tissue
1090
Show that the specific acoustic impedance of gel is 1.68 × 10 6 kg m –2 s –1 .
(i)
[1]
(ii)
Complete Table 8.1 by calculating the missing values to three significant figures. Use the
space below for any working that you need.
[2]
(b) Use the information in (a) to calculate the intensity reflection coefficient for:
(i)
an air–tissue boundary
intensity reflection coefficient = … [2]
(ii)
a gel–tissue boundary.
intensity reflection coefficient = … [1]
(c) Use your answers in (b) to explain why gel is applied to the skin during ultrasound scanning.
…
…
… [2]
[Total: 8]

7
9702/42/M/J/23 · Question 10May/June 2023Paper 429 marks
Loading question…
Question text

10 (a) X-rays for use in medical diagnosis are produced in an X-ray tube. In the X-ray tube, charged
particles are accelerated towards a metal target by an applied potential difference (p.d.).
(i)
State the name of the charged particles that are accelerated by the applied p.d.
… [1]
(ii)
Explain how X-rays are produced at the metal target.
…
…
…
… [2]
(iii)
Calculate the minimum wavelength of X-rays produced when the applied p.d. is 5.80 kV.
wavelength = … m [3]
(b) X-rays pass through a medium that has an attenuation coefficient of 1.4 cm –1 .
Calculate the percentage of the X-ray energy that is absorbed by a 2.8 cm thickness of this
medium.
percentage absorbed = … % [3]
[Total: 9]
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge

8
9702/41/M/J/22 · Question 9May/June 2022Paper 419 marks
Loading question…
Question text

9
(a) (i)
Explain how X-rays are produced for use in medical diagnosis.
…
…
…
… [3]
(ii)
State why X-ray images are taken of multiple sections of the body during computed
tomography (CT) scanning.
…
… [1]
(b) An X-ray image is taken of the structure shown in Fig. 9.1.
2.4 cm
soft tissue
bone
Q
incident
detected
X-rays
X-rays
P
5.6 cm
Fig. 9.1
The linear attenuation coefficient of bone is 3.4 cm –1 .
The linear attenuation coefficient of soft tissue is 0.89 cm –1 .
The incident X-rays are parallel and have a uniform intensity I 0 across the structure.
Determine, in terms of I 0 , the intensity of the detected X-rays from:
(i)
point P
detected intensity = … I 0 [2]
(ii)
point Q.
detected intensity = … I 0 [2]
(c) Explain, with reference to your answers in (b), whether the X-ray image of the structure in
Fig. 9.1 has good contrast.
…
…
… [1]
[Total: 9]

Advertisement
9
9702/41/M/J/21 · Question 4May/June 2021Paper 415 marks
Loading question…
Question text

4
Outline the use of ultrasound to obtain diagnostic information about internal body structures.
…
…
…
…
…
…
…
…
…
… [5]

10
9702/41/M/J/21 · Question 11May/June 2021Paper 417 marks
Loading question…
Question text

11
(a) State how, in a modern X-ray tube, the intensity of the X-ray beam and its hardness are
controlled.
intensity: …
…
hardness: …
…
[2]
(b) A model of a limb consists of soft tissue and bone, as illustrated in Fig. 11.1.
3.0 cm
I 0
I C
incident
transmitted
intensity
intensity
I 0
I S
bone
soft
tissue
9.0 cm
Fig. 11.1
The soft tissue has a thickness of 9.0 cm. The bone within the soft tissue has a thickness of
3.0 cm.
Data for the linear attenuation (absorption) coefficient μ of X-rays in soft tissue and in bone
are shown in Table 11.1.
Table 11.1
μ / cm −1
soft tissue
0.92
bone
2.90
A parallel beam of X-rays of intensity I 0 is incident normally on the model.
Calculate, in terms of I 0 :
(i)
the transmitted intensity I S through soft tissue alone
I S = … I 0 [2]
(ii)
the transmitted intensity I C through soft tissue and bone.
I C = … I 0 [2]
(c) By reference to your answers in (b), suggest, with a reason, whether good contrast on an
X-ray image would be obtained.
…
… [1]
[Total: 7]

11
9702/42/M/J/21 · Question 11May/June 2021Paper 426 marks
Loading question…
Question text

11
(a) State the purpose of computed tomography (CT scanning).
…
… [1]
(b) Outline the principles of CT scanning.
…
…
…
…
…
…
…
…
…
… [5]
[Total: 6]

12
9702/41/M/J/20 · Question 4May/June 2020Paper 417 marks
Loading question…
Question text

4
(a) (i)
By reference to an ultrasound wave, explain what is meant by specific acoustic impedance.
…
…
… [2]
(ii)
An ultrasound wave is incident normally on the boundary between two media. The media
have specific acoustic impedances Z 1 and Z 2 .
State how the ratio
intensity of ultrasound reflected from boundary
intensity of ultrasound incident on boundary
depends on the relative magnitudes of Z 1 and Z 2 .
…
…
…
… [2]
(b) (i)
State what is meant by the attenuation of an ultrasound wave.
…
… [1]
(ii)
A parallel beam of ultrasound is passing through a medium.
The incident intensity I 0 is reduced to 0.35 I 0 on passing through a thickness of 0.046 m
of the medium.
Calculate the linear attenuation coefficient μ of the ultrasound beam in the medium.
μ = … m –1 [2]
[Total: 7]

13
9702/42/M/J/20 · Question 5May/June 2020Paper 427 marks
Loading question…
Question text

5
(a) Explain the principles of the detection of ultrasound waves for medical diagnosis.
…
…
…
…
…
…
…
… [4]
(b) By reference to specific acoustic impedance, explain why there is very little transmission of
ultrasound waves from air into skin.
…
…
…
…
…
… [3]
[Total: 7]

Advertisement
14
9702/41/M/J/19 · Question 9May/June 2019Paper 415 marks
Loading question…
Question text

9
Nuclear magnetic resonance imaging (NMRI) is used to obtain diagnostic information about
internal body structures.
State, during the use of NMRI, the function of:
(a) the large constant magnetic field
…
…
…
…
… [3]
(b) the non-uniform magnetic field.
…
…
…
…
… [2]
[Total: 5]

15
9702/42/M/J/19 · Question 4May/June 2019Paper 427 marks
Loading question…
Question text

4
(a) State what is meant by the specific acoustic impedance of a medium.
…
…
… [2]
(b) A parallel beam of ultrasound of intensity I 0 is incident on the boundary between two media
A and B, as illustrated in Fig. 4.1.
medium A
medium B
specific acoustic impedance Z A
specific acoustic impedance Z B
incident
transmitted
intensity I 0
intensity I T
Fig. 4.1
The two media A and B have specific acoustic impedances Z A and Z B respectively.
The intensity of the beam transmitted through the boundary is I T .
State how the ratio
intensity I T of transmitted beam
intensity I 0 of incident beam
depends on the relative magnitudes of Z A and Z B .
…
…
…
… [2]
(c) The linear absorption (attenuation) coefficient μ of medium B is 23 m –1 .
Calculate the thickness of medium B required to reduce the intensity of the ultrasound beam
to 34% of its initial intensity in medium B.
thickness = … m [3]
[Total: 7]

Advertisement