Medical physics – A Level Physics (9702)

65 questions · page 4 of 5 · Clear filters

0 / 0Answer a question to start your score.
Quick quiz (10)Saved 0
Advertisement
46
9702/41/M/J/18 · Question 4May/June 2018Paper 417 marks
Loading question…
Question text

4
Piezo-electric transducers are used for the generation of ultrasonic waves.
(a) State one other use, apart from in ultrasound, of piezo-electric transducers.
…
… [1]
(b) Explain the main principles behind the use of ultrasound to obtain diagnostic information
about internal body structures.
…
…
…
…
…
…
…
…
…
… [6]
[Total: 7]

47
9702/41/M/J/18 · Question 12May/June 2018Paper 417 marks
Loading question…
Question text

12 An X-ray beam is used to produce an image of a model of a thumb.
A parallel beam of X-ray radiation of intensity I 0 is incident on the model, as illustrated in Fig. 12.1.
soft tissue
bone
emergent beam
1.3 cm
incident beam
intensity I 0
2.8 cm
Fig. 12.1
Data for the attenuation (absorption) coefficient μ in bone and in soft tissue are shown in Fig. 12.2.
μ / cm –1
bone
3.0
soft tissue
0.90
Fig. 12.2
(a) Calculate, in terms of the incident intensity I 0 of the X-ray beam, the intensity of the beam
after passing through
(i)
a thickness of 2.8 cm of soft tissue,
intensity = … I 0 [2]
(ii)
the bone and soft tissue, as shown in Fig. 12.1.
intensity = … I 0 [2]
(b) (i)
State what is meant by the contrast of an X-ray image.
…
…
… [2]
(ii)
By reference to your answers in (a), suggest whether the X-ray image of the model has
good contrast.
…
…
… [1]
[Total: 7]

48
9702/42/M/J/18 · Question 11May/June 2018Paper 427 marks
Loading question…
Question text

11
(a) Describe the basic principles of CT scanning (computed tomography).
…
…
…
…
…
…
…
…
…
…
…
… [5]
(b) By reference to your answer in (a), suggest why
(i)
CT scanning was not possible before fast computers with large memories were available,
…
…
… [1]
(ii)
the radiation dose for a CT scan is much larger than for an X-ray image of a leg bone.
…
…
… [1]
[Total: 7]

Advertisement
49
9702/42/F/M/18 · Question 5Feb/March 2018Paper 4210 marks
Loading question…
Question text

5
(a) Explain the main principles behind the use of ultrasound to obtain diagnostic information
about internal body structures.
…
…
…
…
…
…
…
…
…
…
…
… [6]
(b) (i)
Define specific acoustic impedance.
…
…
… [2]
(ii)
Two media have specific acoustic impedances of Z 1 and Z 2 .
The magnitudes of the acoustic impedances may be almost equal or very different.
State how these differences affect the intensity reflection coefficient at the boundary
between the two media.
Z 1 ≈ Z 2 …
…
Z 1 » Z 2 or Z 1 « Z 2 …
…
[2]
[Total: 10]

50
9702/42/F/M/18 · Question 12Feb/March 2018Paper 426 marks
Loading question…
Question text

12 (a) Suggest two causes of lack of sharpness of an X-ray image.
1. …
…
2. …
… [2]
(b) The thickness of a sheet of metal is examined using a parallel X-ray beam, as illustrated in
Fig. 12.1.
3.2 mm
parallel
X-ray beam
metal
x
sheet
Fig. 12.1 (not to scale)
Part of the beam passes normally through the metal of thickness 3.2 mm. Another part of the
beam passes normally through the metal of thickness x mm.
The linear attenuation (absorption) coefficient for the X-ray beam in the metal is 1.5 cm –1 .
The ratio
intensity of X-ray beam transmitted through 3.2 mm of metal
intensity of X-ray beam transmitted through x mm of metal
is found to be 0.81.
(i)
Calculate the thickness x.
x = … mm [2]
(ii)
The ratio of the intensities is also the ratio of the powers of the X-ray beams.
Calculate this ratio in decibels.
ratio = … dB [2]
[Total: 6]

51
9702/41/O/N/17 · Question 9Oct/Nov 2017Paper 417 marks
Loading question…
Question text

9
(a) In computed tomography (CT scanning), it is necessary to take a series of many X-ray
images.
Outline briefly the principles of CT scanning.
…
…
…
…
…
…
…
…
…
… [4]
(b) A student creates a model for CT scanning.
A section is divided into four voxels, with pixel numbers A, B, C and D, as shown in Fig. 9.1.
A
B
V 1
D
C
V 2
V 4
V 3
Fig. 9.1
The section is viewed from four different directions V 1 , V 2 , V 3 and V 4 , as shown in Fig. 9.1.
The detector readings for each direction are noted and then summed. The result is shown in
Fig. 9.2.
47
59
44
32
Fig. 9.2
The background count is 26.
Determine the pixel numbers A, B, C and D as shown in Fig. 9.1.
A …
B …
D …
C …
[3]
[Total: 7]

52
9702/42/O/N/17 · Question 4Oct/Nov 2017Paper 426 marks
Loading question…
Question text

4
(a) Explain the principles behind the generation of ultrasound waves for diagnosis in medicine.
…
…
…
…
…
…
…
…
…
…
…
…
…
…
… [5]
(b) Ultrasound frequencies as high as 10 MHz are used in medical diagnosis.
Suggest one advantage of the use of high-frequency ultrasound rather than lower-frequency
ultrasound.
…
…
… [1]
[Total: 6]

53
9702/41/M/J/17 · Question 8May/June 2017Paper 418 marks
Loading question…
Question text

8
Explain the main principles behind the use of nuclear magnetic resonance imaging (NMRI) to
obtain information about internal body structures.
…
…
…
…
…
…
…
…
…
…
…
…
…
… [8]
[Total: 8]

Advertisement
54
9702/41/M/J/17 · Question 10May/June 2017Paper 415 marks
Loading question…
Question text

10 (a) State
(i)
what is meant by the hardness of an X-ray beam,
…
…
… [2]
(ii)
how the hardness of an X-ray beam from an X-ray tube is increased.
…
… [1]
(b) The same parallel beam of X-ray radiation is incident, separately, on samples of bone and of
muscle.
Data for the thickness x of the samples of bone and of muscle, together with the linear
attenuation (absorption) coefficients μ of the radiation in bone and in muscle, are given in Fig.
10.1.
μ / cm –1
x / cm
bone
1.5
2.9
muscle
4.0
0.95
Fig. 10.1
Determine the ratio
intensity transmitted through bone
.
intensity transmitted through muscle
ratio = … [2]
[Total: 5]

55
9702/42/M/J/17 · Question 4May/June 2017Paper 429 marks
Loading question…
Question text

4
(a) Explain the main principles behind the use of ultrasound to obtain diagnostic information
about internal body structures.
…
…
…
…
…
…
…
…
…
…
…
…
…
…
… [6]
(b) A parallel beam of ultrasound has intensity I 0 as it enters a muscle of thickness 4.6 cm, as
illustrated in Fig. 4.1.
4.6 cm
muscle
I 0
I T
beam of
ultrasound
Fig. 4.1
The intensity of the beam just before it leaves the muscle is I T .
The ratio I 0 / I T is found to be 2.9.
Calculate the linear attenuation (absorption) coefficient μ of the ultrasound in the layer of
muscle.
μ = … cm –1 [3]
[Total: 9]

56
9702/42/F/M/17 · Question 4Feb/March 2017Paper 424 marks
Loading question…
Question text

4
Explain the main principles of the generation of ultrasound waves for medical use.
…
…
…
…
…
…
…
…
…
… [4]
[Total: 4]

57
9702/41/O/N/16 · Question 8Oct/Nov 2016Paper 418 marks
Loading question…
Question text

8
Explain the main principles behind the use of nuclear magnetic resonance imaging (NMRI) to
obtain diagnostic information about internal body structures.
…
…
…
…
…
…
…
…
…
…
…
… [8]
[Total: 8]

58
9702/42/O/N/16 · Question 5Oct/Nov 2016Paper 426 marks
Loading question…
Question text

5
Ultrasound may be used to obtain information about internal body structures.
(a) Suggest why the ultrasound from the transducer is pulsed.
…
…
… [2]
(b) (i)
State what is meant by specific acoustic impedance.
…
…
… [2]
(ii)
A parallel beam of ultrasound of intensity I 0 is incident normally on the boundary between
two media, as shown in Fig. 5.1.
specific acoustic
specific acoustic
impedance Z 1
impedance Z 2
transmitted beam
incident beam
intensity I T
intensity I 0
Fig. 5.1
The media have specific acoustic impedances Z 1 and Z 2 .
The intensity of the ultrasound beam transmitted across the boundary is I T .
Explain the significance of the magnitudes of Z 1 and of Z 2 on the ratio I T / I 0 .
…
…
…
… [2]
[Total: 6]

Advertisement
59
9702/42/O/N/16 · Question 10Oct/Nov 2016Paper 424 marks
Loading question…
Question text

10 Explain the function of the non-uniform magnetic field that is superimposed on a large uniform
magnetic field in diagnosis using nuclear magnetic resonance imaging (NMRI).
…
…
…
…
…
…
…
… [4]
[Total: 4]

60
9702/42/O/N/16 · Question 13Oct/Nov 2016Paper 426 marks
Loading question…
Question text

13 Outline the principles of computed tomography (CT scanning).
…
…
…
…
…
…
…
…
…
… [6]
[Total: 6]

Advertisement