Medical physics – A Level Physics (9702)

65 questions · page 1 of 5 · Clear filters

0 / 0Answer a question to start your score.
Quick quiz (10)Saved 0
Advertisement
1
9702/41/M/J/26 · Question 8May/June 2026Paper 4113 marks
Loading question…
Question text

8
(a) State what is meant by a photon.
…
…
… [2]
(b) X-rays for use in medical diagnosis are produced by accelerating charged particles towards
a metal target.
(i)
State the name of the charged particles.
… [1]
(ii)
Describe how X-rays are formed at the target.
…
…
… [2]
(iii)
For any given accelerating voltage, there is a range of wavelengths of X-rays produced
that has a minimum value.
Explain, with reference to photons, why there is a range of wavelengths and why this
range has a minimum value.
…
…
…
…
… [3]
(iv)
Calculate the minimum wavelength of X-rays produced when the accelerating voltage
is 52.0 kV.
minimum wavelength = … m [3]
© Cambridge University Press & Assessment 2026
,

,
(c) X-rays are used to create an image of the internal structure of an object that is made from
two types of material of similar thickness.
Describe and explain how a property of the materials determines whether or not the image
produced has good contrast.
…
…
…
… [2]
[Total: 13]
© Cambridge University Press & Assessment 2026

2
9702/44/M/J/26 · Question 9May/June 2026Paper 448 marks
Loading question…
Question text

9
(a) Explain how ultrasound waves are generated by a piezoelectric transducer.
…
…
…
…
… [3]
(b) Ultrasound waves are used to obtain information about a structure that consists of two
materials, as shown in Figure 9.1.
material X
ultrasound waves
P
Q
material Y
not to scale
Figure 9.1
The waves enter the structure at point P and travel through the structure to point Q.
Material Y has a density of 8960 kg m –3 . The speed of sound in material Y is 4720 m s –1 .
(i)
Calculate the specific acoustic impedance Z of material Y. Give a unit with your answer.
Z = … unit … [2]
© Cambridge University Press & Assessment 2026
,
,
(ii)
The intensity of ultrasound entering the structure at point P is I 0 .
The transmitted intensity of the ultrasound between P and Q at distance x from P is I.
Figure 9.2 shows the variation with x of the value of ln (I / I 0 ).
0
0
2
4
6
8
10
12
x / cm
–10
In (I / I 0 )
–20
–30
– 40
Figure 9.2
Determine three conclusions about the structure and the materials from which it is
made that may be drawn from Figure 9.2. The conclusions may be qualitative or
quantitative. Use the space for any working.
1 …
…
2 …
…
3 …
…
[3]
[Total: 8]
© Cambridge University Press & Assessment 2026

3
9702/42/F/M/26 · Question 10Feb/March 2026Paper 4211 marks
Loading question…
Question text

10 (a) (i)
Explain how ultrasound waves are detected by a piezoelectric transducer.
…
…
… [2]
(ii)
Define the specific acoustic impedance of a medium.
…
…
… [2]
(b) Table 10.1 lists the specific acoustic impedances Z of air, water and glass.
Table 10.1
Z / kg m –2 s –1
medium
4.39 × 10 2
air
1.49 × 10 6
water
9.98 × 10 6
glass
The density of water is 998 kg m –3 .
(i)
Determine the speed of sound in water.
speed = … m s –1 [2]
© Cambridge University Press & Assessment 2026
,
,
(ii)
Calculate, to three significant figures, the intensity reflection coefficient for sound
incident on a water-glass boundary.
intensity reflection coefficient = … [2]
(iii)
Explain, without calculation, what happens when sound is incident on an
air-glass boundary.
…
…
…
…
… [3]
[Total: 11]
© Cambridge University Press & Assessment 2026
,
,
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (Cambridge University Press & Assessment) to trace copyright holders, but if any items requiring clearance
have unwittingly been included, the publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in our Copyright
Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download at www.cambridgeinternational.org after the live
examination series.
Cambridge International Education is the name of our awarding body and a part of Cambridge University Press & Assessment, which is a department of the
University of Cambridge.
© Cambridge University Press & Assessment 2026

Advertisement
4
9702/41/O/N/25 · Question 10Oct/Nov 2025Paper 418 marks
Loading question…
Question text

10 (a) Define specific acoustic impedance.
…
…
… [2]
(b) Explain how ultrasound waves are detected by a piezoelectric crystal.
…
…
… [2]
(c) Table 10.1 shows the specific acoustic impedance Z for body tissue, water and steel.
Table 10.1
Z / kg m –2 s –1
material
1.38 × 10 6
body tissue
1.48 × 10 6
water
4.04 × 10 7
steel
(i)
Calculate the intensity reflection coefficient for ultrasound incident on a water–steel
boundary.
intensity reflection coefficient = … [2]
(ii)
Explain, without calculation, what is likely to happen when ultrasound is incident on a
body tissue–water boundary.
…
…
… [2]
[Total: 8]
ĬÑĊ¾Ġ´íÈõÏĪÅĊÞú¶Ă×
,
,
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
ĬÑĊ¾Ġ´íÈõÏĪÅĊàú¶Ą×

5
9702/42/O/N/25 · Question 10Oct/Nov 2025Paper 429 marks
Loading question…
Question text

10 (a) State what is meant by contrast in an X-ray image.
…
… [1]
(b) X-rays of intensity I 0 are incident normally on a structure, as shown in Fig. 10.1.
2.1 cm
material P
material Q
A
incident X-rays,
detected
intensity I 0
X-rays
B
5.8 cm
Fig. 10.1
Material P has a linear attenuation coefficient of 0.35 cm –1 .
The X-rays emerging from the structure in region A have an intensity of 0.053I 0 .
Show that the intensity of the X-rays emerging in region B is 0.13I 0 .
(i)
[1]
ĬÑĊ¾Ġ´íÈõÏĪÅĊßù¶Ă×
,
,
Determine the linear attenuation coefficient μ of material Q.
(ii)
μ = … cm –1 [3]
(iii)
Use the information in (b)(i) to suggest why the X-rays emerging from the structure form
an image that has poor contrast.
…
…
… [1]
(c) Explain how X-rays are used in computed tomography (CT) scanning to produce a
three-dimensional image of an internal structure.
…
…
…
…
… [3]
[Total: 9]
ĬÓĊ¾Ġ´íÈõÏĪÅĊßû¶Ă×
,
,
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
ĬÑĊ¾Ġ´íÈõÏĪÅĊÝù¶Ą×

6
9702/43/O/N/25 · Question 10Oct/Nov 2025Paper 438 marks
Loading question…
Question text

10 (a) Define specific acoustic impedance.
…
…
… [2]
(b) Explain how ultrasound waves are detected by a piezoelectric crystal.
…
…
… [2]
(c) Table 10.1 shows the specific acoustic impedance Z for body tissue, water and steel.
Table 10.1
Z / kg m –2 s –1
material
1.38 × 10 6
body tissue
1.48 × 10 6
water
4.04 × 10 7
steel
(i)
Calculate the intensity reflection coefficient for ultrasound incident on a water–steel
boundary.
intensity reflection coefficient = … [2]
(ii)
Explain, without calculation, what is likely to happen when ultrasound is incident on a
body tissue–water boundary.
…
…
… [2]
[Total: 8]
ĬÑĊ¾Ġ´íÈõÏĪÅĊßûµĂ×
,
,
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
ĬÑĊ¾Ġ´íÈõÏĪÅĊÝûµĄ×

7
9702/44/O/N/25 · Question 8Oct/Nov 2025Paper 4415 marks
Loading question…
Question text

Oxygen-15 ( 158 O ) is radioactive and has a half-life of 2.04 minutes.
8
The decay of oxygen-15 produces positrons. For this reason, oxygen-15 is sometimes used as a
tracer in positron emission tomography (PET scanning).
(a) State what is meant by a tracer.
…
…
… [2]
(b) The equation for the decay of oxygen-15 is
15 O
P
R β +
Q X
+
+ Z
8
S
where X is the nucleus formed during the decay and Z is another particle.
(i)
State the values of the integers P, Q, R and S.
P = …
R = …
Q = …
S = …
[2]
(ii)
State the name of particle Z.
… [1]
(c) (i)
Define the activity of a sample.
…
… [1]
(ii)
Calculate the decay constant of oxygen-15. Give a unit with your answer.
decay constant = … unit … [2]
ĬÍĊ¾Ġ´íÈõÏĪÅĊÝû·Ą×
,
,
(iii)
Determine the rate at which positrons are produced in a sample of oxygen-15 that has a
mass of 2.85 × 10 –6 kg.
rate = … s –1 [4]
(d) The particles that are emitted from the body and detected outside it during PET scanning are
not positrons but another type of particle.
(i)
State the name of the particles that are detected.
… [1]
(ii)
Explain how these particles are formed inside the body.
…
…
…
… [2]
[Total: 15]
ĬÏĊ¾Ġ´íÈõÏĪÅĊÝù·Ą×

8
9702/44/M/J/25 · Question 10May/June 2025Paper 449 marks
Loading question…
Question text

10 (a) Describe how the piezoelectric crystal in a transducer generates ultrasound waves for use in
medical diagnosis.
…
…
…
…
… [3]
(b) A parallel ultrasound beam is incident on the boundary between two media, as illustrated
in Fig. 10.1.
ultrasound
beam
specific acoustic
specific acoustic
impedance Z 2
impedance Z 1
Fig. 10.1
The media have specific acoustic impedances Z 1 and Z 2 .
At the boundary, a fraction α of the incident intensity of the ultrasound beam is reflected. The
remainder is transmitted.
(i)
State what is meant by specific acoustic impedance.
…
…
… [2]
Describe how α depends on the relative values of Z 1 and Z 2 .
(ii)
…
…
…
… [2]
ĬÍĊ¾Ġ´íÈõÏĪÅĊÞú·Ą×
,
,
(c) A parallel ultrasound beam of intensity I 0 enters a region of soft tissue. After passing a
distance of 2.1 cm through this tissue, the intensity of the ultrasound is 0.62 I 0 .
Calculate the linear attenuation coefficient μ of ultrasound in the soft tissue. Give a unit with
your answer.

μ = … unit … [2]
[Total: 9]
ĬÏĊ¾Ġ´íÈõÏĪÅĊÞü·Ą×

Advertisement
9
9702/42/F/M/25 · Question 4Feb/March 2025Paper 4212 marks
Loading question…
Question text

4
A small crystal is made to vibrate with simple harmonic motion. The variation with time t of the
displacement x of one surface of the crystal from its equilibrium position is shown in Fig. 4.1.
50
x / 10 −6 m
t / 10 −6 s
0
0
0.1
0.2
0.3
0.4
0.5
0.6
–50
Fig. 4.1
(a) Show that the angular frequency of the vibration of the surface is 4.2 × 10 7 rad s –1 .
[2]
(b) Determine the maximum acceleration a 0 of the vibration of the surface.
a 0 = … m s –2 [2]
(c) The crystal may be modelled as a single mass of 2.4 × 10 – 4 kg that vibrates as shown
in Fig. 4.1.
Calculate the total energy E of the vibrations.
E = … J [3]
ĬÙĊ¾Ġ´íÈõÏĪÅĊÞù¸Ā×
,
,
(d) The crystal generates ultrasound waves that are used to obtain diagnostic information about
internal structures.
(i)
The crystal is made from piezoelectric material.
Explain how the crystal is made to vibrate.
…
…
…
… [2]
(ii)
A parallel beam of ultrasound waves is incident on a muscle‑bone boundary. Data for
muscle and bone are given in Table 4.1.
Table 4.1
density / kg m –3
speed of sound / m s –1
material
muscle
1100
1600
bone
1900
4100
Calculate the percentage of the intensity of the ultrasound beam that is transmitted at
this boundary.
percentage transmitted = … % [3]
[Total: 12]
ĬÛĊ¾Ġ´íÈõÏĪÅĊÞû¸Ā×

10
9702/41/O/N/24 · Question 9Oct/Nov 2024Paper 4110 marks
Loading question…
Question text

Fluorine-18 ( 189 F) decays by beta-plus (β + ) emission with a half-life of 110 minutes.
9
(a) (i)
State the name of the beta-plus particle.
… [1]
Show that the decay constant of fluorine-18 is 1.05 × 10 –4 s –1 .
(ii)
[1]
Determine the activity of 2.1 × 10 –12 kg of fluorine-18.
(iii)
activity = … Bq [3]
(b) A small sample of fluorine-18 injected into the body acts as a tracer for use in medical imaging.
Describe how the interaction of a β + particle with an electron in the body enables the
(i)
formation of an image.
…
…
…
…
… [3]
(ii)
Suggest why 110 minutes is a suitable half-life for a nuclide used as a tracer in medical
diagnosis.
…
…
… [2]
[Total: 10]
ĬÏĊ¾Ġ´íÈõÏĪÅĊßù¸Ą×

11
9702/43/O/N/24 · Question 9Oct/Nov 2024Paper 4310 marks
Loading question…
Question text

Fluorine-18 ( 189 F) decays by beta-plus (β + ) emission with a half-life of 110 minutes.
9
(a) (i)
State the name of the beta-plus particle.
… [1]
Show that the decay constant of fluorine-18 is 1.05 × 10 –4 s –1 .
(ii)
[1]
Determine the activity of 2.1 × 10 –12 kg of fluorine-18.
(iii)
activity = … Bq [3]
(b) A small sample of fluorine-18 injected into the body acts as a tracer for use in medical imaging.
Describe how the interaction of a β + particle with an electron in the body enables the
(i)
formation of an image.
…
…
…
…
… [3]
(ii)
Suggest why 110 minutes is a suitable half-life for a nuclide used as a tracer in medical
diagnosis.
…
…
… [2]
[Total: 10]
ĬÏĊ¾Ġ´íÈõÏĪÅĊßü¸Ą×

12
9702/41/M/J/24 · Question 8May/June 2024Paper 4113 marks
Loading question…
Question text

8
(a) State what is meant by a photon.
…
…
… [2]
(b) Fig. 8.1 shows a tube in which X-rays are produced at a metal target.
X
Y
particles
filament
vacuum
glass tube
metal target
Fig. 8.1
Particles are accelerated from the filament to the target by a constant high voltage applied
across the terminals X and Y.
(i)
State the name of the particles.
… [1]
(ii)
On Fig. 8.1, use + and – signs to label terminals X and Y to indicate the polarity of the
high voltage.
[1]
(c) For an accelerating voltage of 32 kV in Fig. 8.1, determine:
(i)
the maximum energy, in MeV, of an X-ray photon produced at the target
maximum photon energy = … MeV [1]
(ii)
the maximum momentum of an X-ray photon produced at the target
maximum photon momentum = … N s [2]
(iii)
the minimum wavelength of X-rays produced at the target.
minimum wavelength = … m [3]
(d) Explain why X-rays can be used to produce images of internal body structures that have
good contrast.
…
…
…
…
… [3]
[Total: 13]

13
9702/42/M/J/24 · Question 10May/June 2024Paper 427 marks
Loading question…
Question text

10 (a) Describe how reflected ultrasound pulses may be used to obtain diagnostic information about
internal structures.
…
…
…
… [2]
(b) (i)
Define specific acoustic impedance of a medium.
…
…
… [2]
(ii)
Table 10.1 shows some data for water and for glass.
Table 10.1
density / kg m –3
speed of sound / m s –1
water
1000
1420
glass
2500
4560
Determine the intensity reflection coefficient for ultrasound that is incident on a
water–glass boundary.
intensity reflection coefficient = … [3]
[Total: 7]
,
,
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge

Advertisement
14
9702/42/F/M/24 · Question 9Feb/March 2024Paper 4213 marks
Loading question…
Question text

9
(a) Electrons in a vacuum are accelerated through a potential difference of 84 kV. The electrons
then strike a metal target and X‑rays are produced.
(i)
Calculate the minimum wavelength of the X‑rays that are produced.
wavelength = … m [2]
(ii)
The melting points of two metals are given in Table 9.1.
Table 9.1
metal
melting point / °C
copper
1090
tungsten
3420
Suggest why the metal target is made from tungsten rather than copper.
…
…
… [2]
(b) An X‑ray beam is incident normally on a sample of soft tissue and bone as shown in Fig. 9.1.
bone
X-ray
beam
soft tissue
Fig. 9.1
Data for the two materials are given in Table 9.2.
Table 9.2
linear attenuation coefficient
specific acoustic impedance
medium
μ / cm –1
Z / 10 6 kg m –2 s –1
soft tissue
0.22
1.7
bone
3.0
7.8
The total thickness of soft tissue is x. The total thickness of bone is also x.
The incident intensity of the X‑ray beam is I 0 . The transmitted intensity of the X‑ray beam is
13% of the incident intensity.
Determine x, in cm.
x = … cm [3]
(c) (i)
Define the specific acoustic impedance of a medium.
…
…
… [2]
(ii)
Use data from Table 9.2 to calculate the percentage of the intensity of ultrasound that is
transmitted at a boundary between soft tissue and bone.
percentage transmitted = … % [2]
(iii)
The ultrasound is now incident on the sample of soft tissue and bone shown in Fig. 9.1.
Suggest two reasons why the transmitted intensity through the sample is less than the
answer in (c)(ii).
1 …
…
2 …
…
[2]
[Total: 13]

15
9702/41/O/N/23 · Question 10Oct/Nov 2023Paper 418 marks
Loading question…
Question text

10 Ultrasound and X-rays are both types of wave that are used in medical diagnosis to form images
of internal body structures.
(a) Complete Table 10.1 to state, for each type of wave:
the method of production of the wave
●
whether the wave that is detected and used to form the image is the wave that has been
●
absorbed, reflected or transmitted by the internal body structure.
Table 10.1
ultrasound
X-rays
…
…
method of
production
…
…
detected wave
(absorbed, reflected
…
…
or transmitted)
[4]
(b) (i)
For one type of wave passing through tissue, the wave has 72% of its initial intensity
after it has passed through 6.2 cm of the tissue.
Calculate the linear attenuation coefficient μ of the tissue for this wave.
μ = … cm –1 [2]
(ii)
Another wave of the same type as in (b)(i) passes through 9.3 cm of the same tissue.
Calculate the percentage of the initial intensity of the wave that is attenuated by the
tissue.
percentage attenuated = … % [2]
[Total: 8]
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge