Physics (9702) · May/June 2012 · Mark scheme 33

Cambridge Physics (9702) mark scheme for paper 33, May/June 2012 — 9702/33/M/J/12, file 9702_s12_ms_33.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS
GCE Advanced Subsidiary Level and GCE Advanced Level

MARK SCHEME for the May/June 2012 question paper
for the guidance of teachers

9702 PHYSICS
9702/33

Paper 3 (Advanced Practical Skills 1),
maximum raw mark 40

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of
the examination. It shows the basis on which Examiners were instructed to award marks. It does not
indicate the details of the discussions that took place at an Examiners’ meeting before marking began,
which would have considered the acceptability of alternative answers.
Mark schemes must be read in conjunction with the question papers and the report on the
examination.

• Cambridge will not enter into discussions or correspondence in connection with these mark schemes.

Cambridge is publishing the mark schemes for the May/June 2012 question papers for most IGCSE,
GCE Advanced Level and Advanced Subsidiary Level syllabuses and some Ordinary Level
syllabuses.

www.dynamicpapers.com
Page 2
1

Mark Scheme: Teachers’ version
GCE AS/A LEVEL – May/June 2012

Syllabus
9702

Paper
33

(a) (ii) Value of h0 in range 0.70 m > h0 > 0.50 m. Consistent with unit.

[1]

(b) (iii) Value of h, less than h0 in (a)(ii), with unit.

[1]

(c) Five sets of readings of h and m scores 5 marks, four sets scores 4 marks etc.
Major help from Supervisor –2 (setting up apparatus). Minor help from Supervisor –1.

[5]

Range of m:
To include 0.350 kg.

[1]

Column headings:
[1]
Each column heading must contain a quantity and a unit.
The unit must conform to accepted scientific convention e.g. m / kg, m(kg) or m in kg,
(h0 – h)/m / m kg–1, 1/m / kg–1
Consistency:
All values of h must be given to the nearest mm.

[1]

Significant figures:
[1]
Significant figures for every row of values of 1/m same as or one greater than m as recorded
in the table.
Calculation:
Values of (h0 – h) /m calculated correctly.

[1]

(d) (i) Axes:
[1]
Sensible scales must be used, no awkward scales (e.g. 3:10).
Scales must be chosen so that the plotted points occupy at least half the graph grid in
both x and y directions.
Scales must be labelled with the quantity that is being plotted.
Scale markings must be no more than 3 large squares apart.
Plotting of points:
All observations in the table must be plotted.
Diameter of plots must be ≤ half a small square (no ‘blobs’).
Work to an accuracy of half a small square.

[1]

Quality:
[1]
All points in the table must be plotted (at least 4) for this mark to be awarded. Scatter of
points must be less than 0.5 kg–1 (0.0005 g–1) of 1/m of a straight line.
(ii) Line of best fit:
[1]
Judge by balance of all points on the grid about the candidate’s line (at least 4 points).
There must be an even distribution of points either side of the line along the full length.
Allow one anomalous point only if clearly indicated by the candidate.
Line must not be kinked or thicker than half a small square.
(iii) Gradient:
The hypotenuse of the triangle must be at least half the length of the drawn line.
Both read-offs must be accurate to half a small square in both x and y directions.
Do not allow ∆x / ∆y.

© University of Cambridge International Examinations 2012

[1]

www.dynamicpapers.com
Page 3

Mark Scheme: Teachers’ version
GCE AS/A LEVEL – May/June 2012

Syllabus
9702

y-intercept:
Either:
Check correct read off from a point on the line and substituted into y = mx + c.
Read off must be accurate to half a small square in both x and y directions.
Or:
Check read-off of the intercept directly from the graph.
(e) Value of P = candidate’s gradient. Value of Q = candidate’s intercept.
Unit for P (e.g. m) consistent with value, and Q (m kg–1)

Paper
33
[1]

[1]
[1]
[Total: 20]

2

(b) (ii) Value of θ0 to the nearest degree or 0.5° in range 70° # θ # 80°

[1]

(iii) Value of θ with unit, θ < θ0

[1]

(iv) Correct calculation of (θ0 – θ)

[1]

(c) (i) Value of raw d with unit to nearest mm.

[1]

(ii) Absolute uncertainty in 2 mm < d < 5 mm.
[1]
If repeated readings have been taken, then the absolute uncertainty can be half the
range. Correct method shown to find the percentage uncertainty.
(d) Second value of θ0 within 1 ºC of first value of θ0.
Second value of θ.
Second value of ∆θ > first value of ∆θ (check second value of d > first value of d).
Evidence of repeat readings of d here or in (c)(i).

[1]
[1]
[1]
[1]

(e) (i) Two values of k calculated correctly.

[1]

(ii) Justification of s.f. in k linked to significant figures in d and ∆θ.

[1]

(iii) Sensible comment relating to the calculated values of k, testing against a criterion
specified by the candidate.
[1]

© University of Cambridge International Examinations 2012

www.dynamicpapers.com
Page 4

Mark Scheme: Teachers’ version
GCE AS/A LEVEL – May/June 2012

Syllabus
9702

Paper
33

(f)
(i) Limitations 4 max.

(ii) Improvements 4 max.

No credit/not enough

A

two results not enough

take more readings and plot a
graph/
calculate more k values and
compare

‘repeat readings’ on its own/
few readings/
take more readings and
(calculate) average k/
only one reading

B

heat lost through sides and /or
bottom

method to reduce heat loss/
lag/
insulate/
polystyrene container

use of lid/
heat loss in warming bowl/cup/
draughts/
heat loss to surroundings

C

temperature change is small/
∆θ values too close

time for longer/
higher starting temperature/
greater range of surface areas

D

large (percentage) uncertainty
in ∆θ

use thermometer with greater
sensitivity or precision/
use thermometer that can read
to 0.1 ºC

use more accurate
thermometer/
thermometer not precise
enough/
not just ‘digital thermometer’

E

water in bowl barely covers
(bulb of) thermometer

use larger volume of water/
use of thermocouple/
other small temperature sensor
(e.g. probe)

not just ‘digital thermometer’
any reference to stirrer/
non-uniform temperature/
thermometer touching base

F

parallax error in measuring d /
reason for difficulty in access
in measuring d

use dividers/calipers

string measurements to
measure d

G

difficult to mark level with
reason

method of making mark stay
e.g. depth gauge/ calibrated
marks/ marker on outside

Do not allow: use of coloured ink/reaction time/fans/draughts/water left behind/beakers not
accurate/ helpers.
[Total: 20]

© University of Cambridge International Examinations 2012

Advertisement