Electromagnetic effects – IGCSE Physics (0625)

158 questions · page 8 of 11 · Clear filters

0 / 0Answer a question to start your score.
Quick quiz (10)Saved 0
Advertisement
106
0625/23/O/N/19 · Question 26Oct/Nov 2019Paper 23Multiple choice
Loading question…
Question text

26 A steel bar is placed in an East-West direction for it to be demagnetised. No other magnet is
nearby.
Which method is not suitable?
A
Hammering the bar.
B
Heating the bar to a very high temperature.
C
Slowly taking the bar out of a coil that carries an alternating current.
D
Slowly taking the bar out of a coil that carries a direct current.

107
0625/23/O/N/19 · Question 35Oct/Nov 2019Paper 23Multiple choice
Loading question…
Question text

35 A step-up transformer produces a 60 V a.c. output from a 12 V a.c. input.
There are 50 turns on the secondary coil.
How many turns are there on the primary coil?
A
5
B
10
C
50
D
250

108
0625/23/O/N/19 · Question 36Oct/Nov 2019Paper 23Multiple choice
Loading question…
Question text

36 An a.c. generator contains a coil that rotates at a rate of 4500 revolutions per minute.
What is the frequency of the alternating current?
1.25 Hz
B
75 Hz
C
150 Hz
D
4500 Hz
A

Advertisement
109
0625/21/M/J/19 · Question 36May/June 2019Paper 21Multiple choice
Loading question…
Question text

36 What is the purpose of the commutator in a d.c. electric motor?
A
to control the speed at which the motor rotates
B
to reverse the direction of the voltage across the power supply every half-turn
C
to reverse the direction of the current in the motor coil every half-turn
D
to reverse the direction of spin of the motor coil every half-turn

110
0625/22/M/J/19 · Question 37May/June 2019Paper 22Multiple choice
Loading question…
Question text

37 Diagram 1 shows an a.c. generator. The coil is turning as shown.
diagram 1
coil
N
S
Diagram 2 shows the output voltage produced by the generator as the coil turns.
Which point on diagram 2 shows the voltage induced when the coil is moving through the position
shown in diagram 1?
diagram 2
A
output
voltage
B
0
0
C
time
D

111
0625/23/M/J/19 · Question 39May/June 2019Paper 23Multiple choice
Loading question…
Question text

39 Which statement about γ-radiation is correct?
A
It consists of very small charged particles.
B
It is a form of electromagnetic radiation.
It is less penetrating than β-radiation.
C
It is more highly ionising than α-radiation.
D

112
0625/21/O/N/18 · Question 9Oct/Nov 2018Paper 21Multiple choice
Loading question…
Question text

9
Which device is designed to convert chemical energy into kinetic energy?
A
an a.c. generator
B
a battery-powered torch
C
a car engine
D
a wind-up mechanical clock

113
0625/21/O/N/18 · Question 27Oct/Nov 2018Paper 21Multiple choice
Loading question…
Question text

27 A bar magnet is placed inside a current-carrying coil. The diagram shows four different
experiments.
1
2
magnet slowly
magnet slowly
removed
removed
–
+
3
4
current in coil
current in coil
slowly reduced
slowly reduced
–
+
In which experiments is the magnet demagnetised?
A
1 and 2
B
1 and 3
C
2 and 4
D
3 and 4

Advertisement
114
0625/21/O/N/18 · Question 30Oct/Nov 2018Paper 21Multiple choice
Loading question…
Question text

30 The table gives data for four different electrical devices.
Which device develops the greatest power?
device
voltage
current
A
car headlight
12 V
3.0 A
B
cooling fan
110 V
0.40 A
C
electric spark generator
400 kV
0.10 mA
D
mains lamp
240 V
0.20 A

115
0625/22/O/N/18 · Question 36Oct/Nov 2018Paper 22Multiple choice
Loading question…
Question text

36 The diagram shows a coil of wire between the poles of a magnet.
20 turns
N
S
+
–
power
supply
The coil consists of 20 turns of insulated wire.
The coil is connected to a variable resistor and a power supply.
How can the turning effect on the coil be increased?
A
by moving the poles of the magnet closer to the coil
B
by reducing the number of turns on the coil while keeping the current constant
C
by increasing the resistance of the variable resistor
D
by reversing the terminals of the power supply

116
0625/23/O/N/18 · Question 27Oct/Nov 2018Paper 23Multiple choice
Loading question…
Question text

27 A bar magnet is placed inside a current-carrying coil. The diagram shows four different
experiments.
1
2
magnet slowly
magnet slowly
removed
removed
–
+
3
4
current in coil
current in coil
slowly reduced
slowly reduced
–
+
In which experiments is the magnet demagnetised?
A
1 and 2
B
1 and 3
C
2 and 4
D
3 and 4

117
0625/23/O/N/18 · Question 28Oct/Nov 2018Paper 23Multiple choice
Loading question…
Question text

28 Which row shows the meaning of the quantity e.m.f. and the unit in which it is measured?
meaning
unit
A
electromagnetic force
N
B
electromagnetic force
V
C
electromotive force
N
D
electromotive force
V

118
0625/21/M/J/18 · Question 1May/June 2018Paper 21Multiple choice
Loading question…
Question text

1
A length of cotton is measured between two points on a ruler.
cotton
cm
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
When the length of cotton is wound closely around a pen, it goes round six times.
six turns of cotton
pen
What is the distance once round the pen?
2.2 cm
B
2.6 cm
C
13.2 cm
D
15.6 cm
A

Advertisement
119
0625/21/M/J/18 · Question 4May/June 2018Paper 21Multiple choice
Loading question…
Question text

4
Diagram 1 shows a beam balance. A beaker with a wire loop balances the standard masses.
The beaker is then removed and hung from a spring. The spring extends by 5.0 cm, as in
diagram 2.
diagram 1
diagram 2
beam
beaker with
spring
standard
balance
wire loop
masses
attached
beaker with
wire loop
attached
The experiment is repeated with the same apparatus on the Moon, where the acceleration of free
fall is less than on Earth.
Which statement describes what happens on the Moon?
The beam balance is balanced and the spring extends by 5.0 cm.
A
The beam balance is balanced and the spring extends by less than 5.0 cm.
B
The right-hand balance pan is higher and the spring extends by 5.0 cm.
C
D
The right-hand balance pan is higher and the spring extends by less than 5.0 cm.

120
0625/21/M/J/18 · Question 26May/June 2018Paper 21Multiple choice
Loading question…
Question text

26 A steel magnet is placed inside a coil of wire.
Which method is used to demagnetise the magnet?
A
connect the coil to an a.c. power supply
B
connect the coil to an a.c. power supply and slowly remove the magnet from the coil
C
connect the coil to a d.c. power supply
D
connect the coil to a d.c. power supply and slowly remove the magnet from the coil

Advertisement