Chemical reactions: rates, equilibrium and redox – IGCSE Chemistry (0620)
43 questions · page 2 of 3 · Clear filters
Question text
4 Hydrogels are powders that absorb water to form hydrated solids. Hydrogels and the hydrated
solids formed are insoluble in water.
Plan an investigation to find which hydrogel, hydrogel A or hydrogel B, is able to absorb the
greater mass of water.
You are provided with samples of hydrogel A, hydrogel B, water and common laboratory apparatus.
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
Question text
2
A
student investigated the rate of the reaction between sodium metabisulfite and potassium iodate
at different temperatures.
Five experiments were done at different temperatures.
(a) Experiment 1
● 70 cm 3 of aqueous potassium iodate was measured using a 100 cm 3 measuring cylinder
and poured into a 250 cm 3 beaker.
● 5 cm 3 of aqueous starch was measured using a 10 cm 3 measuring cylinder and poured into
the beaker containing the aqueous potassium iodate.
cm 3 of aqueous sodium metabisulfite was measured using a clean 10 cm 3 measuring
● 5
cylinder and poured into the beaker. At the same time a stop-clock was started.
● The mixture was stirred until a sudden colour change was seen.
●
The stop-clock was stopped and the temperature of the mixture in the beaker was
measured using a thermometer.
● The beaker was rinsed with distilled water.
Experiment 2
0 cm 3 of aqueous potassium iodate was measured using a 100 cm 3 measuring cylinder
● 7
and poured into a 250 cm 3 beaker.
● 5 cm 3 of aqueous starch was measured using a 10 cm 3 measuring cylinder and poured into
the beaker containing the aqueous potassium iodate.
● The aqueous potassium iodate and starch mixture was warmed over a Bunsen burner
until the temperature of the solution was about 35 °C. The beaker was then removed from
above the Bunsen burner.
cm 3 of aqueous sodium metabisulfite was measured using a clean 10 cm 3 measuring
● 5
cylinder and poured into the beaker. At the same time a stop-clock was started.
● The mixture was stirred until a sudden colour change was seen.
●
The stop-clock was stopped and the temperature of the mixture in the beaker was
measured using a thermometer.
● The beaker was rinsed with distilled water.
Experiment 3
● Experiment 2 was repeated but the aqueous potassium iodate and starch mixture was
warmed until the temperature of the solution was about 40 °C.
Experiment 4
● Experiment 2 was repeated but the aqueous potassium iodate and starch mixture was
warmed until the temperature of the solution was about 45 °C.
Experiment 5
● Experiment 2 was repeated but the aqueous potassium iodate and starch mixture was
warmed until the temperature of the solution was about 50 °C.
Use the thermometer diagrams and stop-clock diagrams to complete the table.
thermometer
temperature
stop-clock
time
experiment
diagram
/ °C
diagram
/ s
0
seconds
0
20
15
1
45 15
5
15
10
10
minutes
30
0
0
40
35
2
45 15
5
15
30
10
30
0
0
45
40
3
45 15
5
15
35
10
30
0
0
50
45
4
45 15
5
15
40
10
30
0
0
55
50
5
45 15
5
15
45
10
30
[4]
(b) Complete a suitable scale on the y-axis and plot the results from Experiments 1 to 5 on the
grid.
Draw a curve of best fit through your points.
time taken
to change
colour / s
0
10
20
30
40
50
60
temperature / C
[4]
(c) Deduce which experiment had the fastest rate of reaction.
… [1]
(d)
From your graph, deduce the time taken for the mixture to change colour at a temperature of
60.0 °C.
Show clearly on the grid how you worked out your answer.
time taken to change colour = … [3]
(e) Experiments are often repeated and the results compared to check that they are reliable.
Suggest why this is difficult to do for these experiments.
…
… [1]
(f) Suggest why the aqueous potassium iodate is warmed before the aqueous sodium metabisulfite
is added rather than after it has been added.
…
…
Question text
2 A student investigated the temperature change when anhydrous lithium chloride dissolves in water.
The student did six experiments.
(a) Experiment 1
● Using a measuring cylinder, 30 cm 3 of distilled water was poured into a 100 cm 3 beaker.
● The initial temperature of the water was measured using a thermometer.
● 1.0 g of anhydrous lithium chloride was added to the water in the beaker. At the same time
a timer was started.
● The water and lithium chloride mixture was continually stirred using a thermometer.
● The temperature of the mixture was measured after 30 seconds.
● The beaker was rinsed with distilled water.
Experiment 2
● Experiment 1 was repeated using 1.5 g of anhydrous lithium chloride instead of the 1.0 g
of anhydrous lithium chloride.
Experiment 3
● Experiment 1 was repeated using 2.0 g of anhydrous lithium chloride instead of the 1.0 g
of anhydrous lithium chloride.
Experiment 4
● Experiment 1 was repeated using 2.5 g of anhydrous lithium chloride instead of the 1.0 g
of anhydrous lithium chloride.
Experiment 5
● Experiment 1 was repeated using 3.0 g of anhydrous lithium chloride instead of the 1.0 g
of anhydrous lithium chloride.
Experiment 6
● Experiment 1 was repeated using 4.0 g of anhydrous lithium chloride instead of the 1.0 g
of anhydrous lithium chloride.
Use the thermometer diagrams to complete the table and calculate the temperature changes.
mass of
initial
after 30 seconds
temperature
anhydrous
experiment
change
lithium chloride thermometer temperature
thermometer
temperature
/ C
diagram
/ C
diagram
/ C
/ g
30
30
1
1.0
25
25
20
20
30
30
2
1.5
25
25
20
20
30
35
3
2.0
25
30
20
25
30
35
4
2.5
25
30
20
25
30
40
5
3.0
25
35
20
30
30
40
6
4.0
25
35
20
30
[5]
(b) Complete a suitable scale on the y-axis and plot the results from Experiments 1 to 6 on the
grid.
Draw a straight line of best fit through your points. The straight line must pass through (0,0).
temperature
change / C
0
2.5
3.0
3.5
0
0.5
1.0
1.5
2.0
4.0
mass of anhydrous lithium chloride / g
[5]
(c)
From your graph, deduce the temperature change when 3.2 g of anhydrous lithium chloride
is dissolved in 30 cm 3 of distilled water.
Show clearly on the grid how you worked out your answer.
temperature change = … °C [2]
(d) E
stimate the temperature change if Experiment 6 is repeated using 60 cm 3 of water instead of
30 cm 3 of water. Give a reason for your answer.
…
…
… [2]
(e) Suggest two changes that could be made to the apparatus to improve the accuracy of the
results. For each change explain why it improves the accuracy of the results.
change 1 …
explanation 1 …
…
change 2 …
explanation 2 …
…
[4]
[Total: 18]
Question text
2 A student investigated the rate of reaction between small lumps of calcium carbonate and dilute
hydrochloric acid.
The experiment was done at two different temperatures using the apparatus shown in the diagram.
All other conditions were kept the same.
gas syringe
dilute hydrochloric acid
calcium carbonate
Experiment 1
● Using a 50 cm 3 measuring cylinder, 25 cm 3 of dilute hydrochloric acid was poured into a boiling
tube.
● The temperature of the dilute hydrochloric acid was measured using a thermometer.
● 10 g of lumps of calcium carbonate were added to the boiling tube, the bung replaced and the
stop‑watch started.
● The volume of gas collected in the gas syringe was measured every 50 seconds for 250 seconds.
Experiment 2
● Using a 50 cm 3 measuring cylinder, 25 cm 3 of dilute hydrochloric acid was poured into a boiling
tube.
● The dilute hydrochloric acid in the boiling tube was warmed using a Bunsen burner.
● The temperature of the dilute hydrochloric acid was measured using a thermometer.
● 10 g of lumps of calcium carbonate were added to the boiling tube, the bung replaced and the
stop‑watch started.
● The volume of gas collected in the gas syringe was measured every 50 seconds for 250 seconds.
(a) Use the diagrams to complete the tables for Experiment 1.
thermometer
temperature of dilute
diagram
hydrochloric acid / °C
30
25
20
volume of gas
time / s
gas syringe diagram
collected / cm 3
0
10 20 30 40 50
50
10 20 30 40 50
100
10 20 30 40 50
150
10 20 30 40 50
200
10 20 30 40 50
250
10 20 30 40 50
[2]
(b) Use the diagrams to complete the tables for Experiment 2.
thermometer
temperature of dilute
diagram
hydrochloric acid / °C
45
40
35
volume of gas
time / s
gas syringe diagram
collected / cm 3
0
10 20 30 40 50
50
10 20 30 40 50
100
10 20 30 40 50
150
10 20 30 40 50
200
10 20 30 40 50
250
10 20 30 40 50
[2]
(c) Plot the results from Experiment 1 and Experiment 2 on the grid.
Draw a curve of best fit for each experiment. Label your curves.
50
40
30
volume of gas
collected / cm 3
20
10
0
0
50
100
150
200
250
300
time / s
[5]
(d)
From your graph, deduce the volume of gas collected in Experiment 2 after 120 seconds.
Show clearly on the grid how you worked out your answer.
… cm 3
[2]
(e) Explain how the results show that the reaction in Experiment 2 has stopped.
…
… [1]
(f) Predict the volume of gas that would be collected in Experiment 1 after 800 seconds.
Explain your answer.
volume of gas collected after 800 seconds … cm 3
explanation …
…
[2]
(g) A student stated it would be an improvement to measure the volume of gas collected every
25 seconds.
Explain why this is an improvement.
…
…
… [2]
(h) State two changes to the apparatus to improve the accuracy of the results obtained if the
experiment is repeated using the same thermometer.
change 1 …
Question text
4 Catalysts are substances which increase the rate of a reaction but are unchanged at the end of the
reaction.
Aqueous hydrogen peroxide decomposes slowly to form water and oxygen.
2H 2 O 2 (aq) → 2H 2 O(l) + O 2 (g)
Copper( II ) oxide is an insoluble solid.
Plan an investigation to find out if copper( II ) oxide is a catalyst for the decomposition of
hydrogen peroxide. You must include how your results will tell you if copper( II ) oxide is a catalyst.
You have access to copper( II ) oxide, aqueous hydrogen peroxide and all normal laboratory
apparatus.
…
…
…
…
…
…
…
…
…
…
…
…
… [6]
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of the University of
Question text
4 Dilute hydrochloric acid reacts with calcium carbonate to make carbon dioxide gas. The apparatus
shown in the diagram can be used to follow the progress of the reaction. The carbon dioxide gas
leaves the flask causing the mass shown on the balance to decrease.
cotton wool
dilute hydrochloric acid
calcium carbonate
balance
260.00
Plan an investigation, using the apparatus shown in the diagram, to find out how the temperature
of the dilute hydrochloric acid affects the rate of the reaction. Your plan should include how your
results will show how the temperature of the dilute hydrochloric acid affects the rate of the reaction.
You are provided with dilute hydrochloric acid, calcium carbonate and common laboratory apparatus.
…
…
…
…
…
…
…
…
…
…
…
…
…
…
… [6]
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of the University of
Question text
4 The mineral epsomite contains hydrated magnesium sulfate. When epsomite is heated strongly, it
loses water and eventually becomes anhydrous magnesium sulfate.
Plan an investigation to find the percentage by mass of water in a sample of epsomite. Your plan
should include how you would calculate the percentage by mass of water in epsomite.
You have access to common laboratory apparatus.
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
… [6]
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Camb
Question text
2 A student investigated the rate at which hydrogen gas was made when magnesium reacted with
dilute sulfuric acid.
Five experiments were carried out using the apparatus shown.
rubber delivery tube
clamp
inverted 100 cm 3
bung
measuring cylinder
conical flask
trough
water
Experiment 1
● Using a measuring cylinder, 25 cm 3 of dilute sulfuric acid was poured into a conical flask.
● Using a different measuring cylinder, 30 cm 3 of distilled water was poured into the conical flask.
● The apparatus was set up as shown in the diagram.
● The bung was removed from the conical flask.
● A coiled length of magnesium ribbon was added to the conical flask, the bung was replaced
immediately and a timer started.
● The volume of gas collected in the inverted measuring cylinder after 30 seconds was measured.
Experiment 2
● Experiment 1 was repeated using 20 cm 3 of distilled water instead of 30 cm 3 .
Experiment 3
● Experiment 1 was repeated using 10 cm 3 of distilled water instead of 30 cm 3 .
Experiment 4
● Experiment 1 was repeated using 5 cm 3 of distilled water instead of 30 cm 3 .
Experiment 5
● Experiment 1 was repeated without adding any distilled water to the dilute sulfuric acid.
(a) Use the information in the description of the experiments and the inverted measuring cylinder
diagrams to complete the table.
volume of gas
volume of
volume of dilute
inverted measuring
experiment
collected in
distilled water
sulfuric acid / cm 3
cylinder diagram
30 seconds / cm 3
/ cm 3
10
1
20
30
10
2
20
30
30
3
40
50
50
4
60
70
80
5
90
100
[4]
(b) Plot the results from Experiments 1 to 5 on the grid. Draw a smooth curve of best fit.
100
80
60
volume of gas
collected in
30 seconds / cm 3
40
20
0
0
5
10
15
20
25
30
35
40
volume of distilled water / cm
3
[3]
(c) Extrapolate (extend) the line on your graph and deduce the volume of gas that would be
collected in 30 seconds if 35 cm 3 of distilled water was added to the dilute sulfuric acid.
… cm 3
[2]
(d) The rate of reaction can be calculated using the equation shown.
volume of gas collected
rate of reaction =
time taken to collect the gas
(i) Use this equation to calculate the rate of reaction in Experiment 3. Give the units for the
rate you have calculated.
rate = …
units = …
[2]
(ii) State which Experiment, 1, 2, 3, 4 or 5, had the highest rate of reaction.
… [1]
(e) The volume of the dilute sulfuric acid was measured using a measuring cylinder. A 25 cm 3
pipette could have been used instead of a measuring cylinder.
(i) State one advantage of using a 25 cm 3 pipette instead of a measuring cylinder.
… [1]
(ii) State one disadvantage of using a 25 cm 3 pipette instead of a measuring cylinder.
… [1]
(f) Name another item of apparatus, which can be used instead of an inverted measuring cylinder,
to collect and measure the volume of gas made in the reaction.
… [1]
(g) The diagram shows a modified conical flask that could be used in this investigation.
glass divider
magnesium
dilute sulfuric acid
E
xplain the advantage of using this type of conical flask instead of the type used in the
investigation.
…
…
Question text
2
A
student investigated the rate of a reaction between sodium metabisulfite and potassium iodate.
In the reaction, starch was used as an indicator. At first the reacting mixture remained colourless
but then suddenly changed to a blue-black colour.
Five experiments were done. In each experiment the total volume of liquid was 45 cm 3 .
Experiment 1
● ● Using a 10 cm 3 measuring cylinder, 5 cm 3 of aqueous sodium metabisulfite was poured into a
beaker.
● ● Using another 10 cm 3 measuring cylinder, 5 cm 3 of aqueous starch was poured into the beaker.
● ● Using a 25 cm 3 measuring cylinder, 15 cm 3 of distilled water was poured into the beaker.
● ● Using another 25 cm 3 measuring cylinder, 20 cm 3 of aqueous potassium iodate was poured into
the beaker. At the same time a stop‑clock was started.
● ● The mixture in the beaker was stirred until a sudden colour change was seen.
● ● The stop‑clock was immediately stopped and the time recorded.
● ● The beaker was rinsed with water.
Experiment 2
of
distilled
water
and
18 cm 3
of
● ●
Experiment 1 was repeated
using
17 cm 3
aqueous potassium iodate.
Experiment 3
of
distilled
water
and
14 cm 3
of
● ●
Experiment 1 was repeated
using
21 cm 3
aqueous potassium iodate.
Experiment 4
of
distilled
water
and
12 cm 3
of
● ●
Experiment 1 was repeated
using
23 cm 3
aqueous potassium iodate.
Experiment 5
of
distilled
water
and
10 cm 3
of
● ●
Experiment 1 was repeated
using
25 cm 3
aqueous potassium iodate.
(a) Use the information in the description of the experiments and the stop‑clock diagrams to
complete the table. Record the times in seconds.
volume of
time to
volume
volume of
aqueous sodium
change
of distilled
aqueous
experiment
stop‑clock diagram
metabisulfite
colour
water
potassium
/ cm 3
/ s
/ cm 3
iodate / cm 3
0
seconds
0
45 15
5
15
1
20
10
minutes
30
0
0
45 15
5
15
2
18
10
30
0
0
45 15
5
15
3
14
10
30
0
0
45 15
5
15
4
12
10
30
0
0
45 15
5
15
5
10
10
30
[5]
(b) Plot the results from Experiments 1 to 5 on the grid.
Draw a smooth curve of best fit.
80
70
60
time to change
colour / s
50
40
30
10
12
14
16
18
22
20
volume of aqueous potassium iodate / cm 3
[3]
(c) (i)
From your graph, predict the time to change colour if 16 cm 3 of aqueous potassium iodate
was used.
Show clearly on the grid how you worked out your answer.
time to change colour = … s [2]
(ii) Calculate the volume of distilled water required if 16 cm 3 of aqueous potassium iodate was
used.
volume of distilled water = … cm 3 [1]
(d) Sketch on the grid the graph you would expect if Experiments 1 to 5 were repeated at a higher
temperature.[1]
(e) The concentration of potassium iodate in the reaction mixture in each experiment can be
calculated using the equation shown.
0.05 × volume of aqueous potassium iodate
concentration =
45
(i) Calculate the concentration of potassium iodate in the reaction mixture in Experiment 2.
concentration = … mol / dm 3 [1]
(ii) State which experiment, 1, 2, 3, 4 or 5, had the fastest rate of reaction.
… [1]
(f) Suggest why the volume of distilled water added to each experiment was increased as the
volume of aqueous potassium iodate was decreased.
…
… [1]
(g) Give one change you could make to the apparatus used which would improve the results.
Explain your answer.
change to apparatus …
…
Question text
4 Many window-cleaning products contain aqueous ammonia. Aqueous ammonia is an alkali that
reacts with dilute acids.
Plan an investigation to find which of two window-cleaning products contains the most concentrated
aqueous ammonia. Include in your plan:
● ● the method you will use
● ● how your results will be used to determine which window-cleaning product contains the most
concentrated aqueous ammonia.
You are provided with an aqueous solution of the two window‑cleaning products,
dilute hydrochloric acid of known concentration and common laboratory apparatus.
…
…
…
…
…
…
…
…
…
…
…
…
… [6]
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of the University of
Question text
2 A student investigated the time taken to collect 40 cm 3 of hydrogen gas when magnesium reacts
with dilute sulfuric acid.
Five experiments were done using the apparatus shown.
inverted 50 cm 3
measuring cylinder
dilute sulfuric acid
water
and distilled water
Experiment 1
● ● Using a measuring cylinder, 8 cm 3 of dilute sulfuric acid was poured into the boiling tube.
● ● Using a second measuring cylinder, 12 cm 3 of distilled water was added to the acid in the
boiling tube.
● ● The apparatus was set up as shown in the diagram, ensuring the inverted measuring cylinder
was full of water.
● ● The bung was removed from the boiling tube.
● ● A coiled length of magnesium ribbon was added to the boiling tube, the bung was immediately
replaced and a timer started.
● ● The time taken for 40 cm 3 of gas to be collected was measured.
● ● The student felt the outside of the boiling tube.
(a) (i) The student noticed that the boiling tube was warm.
What does this tell you about the type of reaction?
… [1]
(ii) Describe one change that could be made to the apparatus to help keep the temperature
of the contents of the boiling tube constant during the reaction.
… [1]
Experiment 2
● ● The boiling tube was rinsed out with distilled water.
● ● Experiment 1 was repeated using 10 cm 3 of dilute sulfuric acid and 10 cm 3 of distilled water.
Experiment 3
● ● Experiment 2 was repeated using 12 cm 3 of dilute sulfuric acid and 8 cm 3 of distilled water.
Experiment 4
● ● Experiment 2 was repeated using 16 cm 3 of dilute sulfuric acid and 4 cm 3 of distilled water.
Experiment 5
● ● Experiment 2 was repeated using 20 cm 3 of dilute sulfuric acid and no distilled water.
(b) Use the information in the description of the experiments and the timer diagrams to complete
the table. Record the time in seconds.
volume of
volume of
time to collect
experiment
dilute sulfuric
timer diagram
distilled water
40 cm 3 of gas / s
acid / cm 3
/ cm 3
0
seconds
0
45 15
5
15
1
8
10
minutes
30
0
0
45 15
5
15
2
10
10
30
0
0
45 15
5
15
3
12
10
30
0
0
45 15
5
15
4
16
10
30
0
0
45 15
5
15
5
20
10
30
[4]
(c) Add a suitable scale to the y-axis and plot the results from Experiments 1 to 5 on the grid.
Draw a smooth line graph.
time to collect
40 cm 3 of gas / s
6
8
10
12
14
20
16
18
volume of dilute sulfuric acid / cm
3
[4]
(d) (i)
From your graph, deduce the time taken to collect 40 cm 3 of gas if the experiment was
repeated using 9 cm 3 of dilute sulfuric acid.
Show clearly on the grid how you worked out your answer.
… s
[2]
(ii)
What volume of distilled water would be needed if the experiment was repeated
using 9 cm 3 of dilute sulfuric acid?
… cm 3 [1]
(e) The rate of reaction can be calculated using the equation shown.
volume of gas collected
rate of reaction =
time taken to collect the gas
(i) Use this equation to calculate the rate of reaction in Experiment 1. Give the units for the
rate of reaction you have calculated.
rate of reaction = … units = …
[2]
(ii) In which Experiment, 1, 2, 3, 4 or 5, was the rate of reaction greatest?
… [1]
(f) Why would measuring the volume of dilute sulfuric acid with a burette rather than a measuring
cylinder be an improvement?
…
…
Question text
2
A student investigated the rate of reaction between dilute nitric acid and an excess of
solid magnesium carbonate at room temperature.
The apparatus was set up as shown in the diagram.
A small test‑tube containing magnesium carbonate was suspended in the conical flask.
inverted 250 cm 3
measuring
cylinder
solid
magnesium
carbonate
water
dilute
nitric acid
50 cm 3 of dilute nitric acid was added to the conical flask. The contents of the test‑tube were
released, allowing the solid magnesium carbonate to mix with the dilute nitric acid. A stop‑clock was
started and the volume of gas collected in the inverted measuring cylinder was measured every
10 seconds for 80 seconds.
(a) Use the inverted measuring cylinder diagrams to record the volume of gas collected in the
table.
inverted
total volume of
time / s
measuring cylinder
gas collected / cm 3
diagram
0
0
5
10
20
10
25
30
40
20
45
50
55
30
60
65
60
40
65
70
70
50
75
80
70
60
75
80
70
70
75
80
70
80
75
80
[2]
(b) Plot the results on the grid. Draw a smooth line graph.
80
70
60
50
total
volume
of gas
40
collected
/ cm 3
30
20
10
0
30
40
50
60
70
80
0
10
20
time / s
[3]
(c) (i) One of the points is anomalous.
Circle this point on your graph.
[1]
(ii)
From your graph, deduce the time taken to collect 40 cm 3 of gas.
Show clearly on the grid how you worked out your answer.
… s [2]
(d) State one possible source of error in this experiment. Suggest one improvement to reduce this
source of error.
source of error …
improvement …
[2]
(e) The average rate of the reaction can be calculated using the equation shown.
volume of gas collected / cm 3
average rate of reaction =
time taken / s
(i) Calculate the volume of gas collected between 10 seconds and 30 seconds.
… [1]
(ii)
Calculate the average rate of reaction between 10 seconds and 30 seconds. Include the
unit in your answer.
average rate of reaction = …
unit = …
[2]
(f) The student calculated that the total volume of gas collected in this reaction would be 85 cm 3 .
Suggest and explain why the actual volume of gas collected was different from 85 cm 3 .
…
…
… [2]
(g) S
ketch on the grid the graph you would expect if the experiment were repeated at a lower
temperature. Label this graph as L.[2]
[Total: 17]
Question text
1 Hydrogen peroxide, H 2 O 2 (aq), decomposes slowly to form water and oxygen.
2H 2 O 2 (aq)
2H 2 O(l) + O 2 (g)
The addition of 0.5 g of manganese( IV ) oxide speeds up this decomposition. Manganese( IV ) oxide
is an insoluble solid.
The apparatus shown was used to follow the rate of decomposition of hydrogen peroxide. The
hydrogen peroxide was added to the conical flask and a stop‑watch was started.
hydrogen peroxide
water
0.5 g manganese( IV ) oxide
(a) Complete the box to name the apparatus.
[1]
(b) What measurements should be taken to follow the rate of the reaction?
…
… [2]
(c) The rate of the reaction decreases over time. After 5 minutes the rate of reaction is zero.
(i) Why does the rate of reaction decrease?
… [1]
(ii)
Explain why the rate of reaction is zero after 5 minutes.
… [1]
(d) (i) The manganese( IV ) oxide acts as a catalyst.
How could a student separate the catalyst from the reaction mixture at the end of the
reaction?
… [1]
(ii) Suggest how the student could show that the catalyst separated in (d)(i) is unchanged at
the end of the reaction.
…
…
…
… [3]
[Total: 9]
Question text
2 A student investigated the rate of reaction between magnesium ribbon and solutions of dilute
hydrochloric acid of different concentrations, solutions H, I, J and K. The dilute hydrochloric acid
was in excess in all experiments.
Five experiments were done.
Experiment 1
● ● A measuring cylinder was used to pour 30 cm 3 of solution H into a beaker.
● ● A 5.0 cm length of magnesium ribbon was then added to the beaker.
● ● A timer was started immediately.
● ● The time taken for all of the magnesium ribbon to react and to disappear completely was
measured.
Experiment 2
● ● Experiment 1 was repeated but using solution I instead of solution H.
Experiment 3
● ● Experiment 1 was repeated but using solution J instead of solution H.
Experiment 4
● ● Experiment 1 was repeated but using solution K instead of solution H.
(a) Use the stop-clock diagrams to record the time taken for each experiment in the table.
concentration of
time taken for the
stop-clock
experiment
solution
hydrochloric acid
magnesium ribbon to
diagram
in mol / dm 3
disappear completely / s
0
45 15
5
15
H
1
2.0
10
minutes
0
45 15
5
15
I
2
1.5
10
0
45 15
5
15
J
3
1.0
10
0
45 15
5
15
K
4
0.8
10
[3]
Experiment 5
Solution J was added to some magnesium ribbon in a test‑tube. The gas produced was tested. The
observations were recorded in the table.
rapid effervescence and the test-tube felt hot
observations
lighted splint ‘popped’
(b) Plot the results for Experiments 1–4 on the grid. Draw a smooth line graph.
time taken for the
magnesium ribbon to
disappear completely / s
0
0.5
1.0
1.5
2.0
2.5
3.0
concentration of hydrochloric acid in mol / dm
3
[3]
(c)
From your graph, deduce the time taken for the magnesium ribbon to disappear completely
if a solution of hydrochloric acid of concentration 2.5 mol / dm 3 were used.
Show clearly on the grid how you worked out your answer.
… [3]
(d) (i) Why was the same length of magnesium used in Experiments 1–4?
… [1]
(ii) Suggest the effect on the results if Experiments 1–4 were repeated using 2.5 cm lengths of
magnesium ribbon instead of 5.0 cm lengths of magnesium ribbon. Explain your answer.
…
… [1]
(e) Suggest a different method which a student could use to investigate the rate of reaction
between magnesium ribbon and dilute hydrochloric acid. State the apparatus the student
would use and the measurements the student would take.
apparatus …
…
measurements …
…
…
[3]
(f) Use the observations from Experiment 5 to answer these questions.
(i)
What type of chemical reaction occurs when magnesium ribbon reacts with dilute
hydrochloric acid?
… [1
Question text
4 The rate of reaction between magnesium and dilute hydrochloric acid can be followed by measuring
the volume of hydrogen produced.
Plan an experiment to investigate the effect of decreasing the temperature on the rate of this
reaction by measuring the volume of hydrogen produced.
You are provided with magnesium ribbon, dilute hydrochloric acid and common laboratory
apparatus.
You are advised to draw a labelled diagram of the apparatus you would use in the space provided.
…
…
…
…
…
…
…
…
…
…
… [6]
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of the University of