Enzymes – IGCSE Biology (0610)
12 questions · Clear filters
Question text
2
(a) Figure 2.1 is a photograph of three beans in a pod.
P
Q
Figure 2.1
(i)
Draw a large diagram of the three beans and the pod shown in Figure 2.1.
[4]
© Cambridge University Press & Assessment 2026
,
,
(ii)
Line PQ represents the length of one of the beans in Figure 2.1.
Measure the length of line PQ.
length of line PQ … mm
The actual length of the bean is 19 mm.
Using your measurement and the formula, calculate the magnification of the bean
in Figure 2.1.
length of line PQ
magnification =
actual length of the bean
Give your answer to two significant figures.
Space for working.
…
[3]
(b) A student investigated the effect of temperature on the time taken for beans to germinate.
The student:
•
planted 200 beans in trays containing soil, and kept them at 10 °C
added 45 cm 3 of water to the trays each day
•
•
recorded the time when each bean started to germinate
•
calculated the mean time for germination
•
repeated the procedure at 20 °C, 30 °C, 40 °C and 50 °C.
(i)
Identify the independent variable in this investigation.
… [1]
(ii)
Identify one variable that was kept constant in this investigation.
… [1]
(iii)
Suggest why the student planted so many beans.
…
…
… [1]
State the most appropriate piece of apparatus for measuring 45 cm 3 of water.
(iv)
… [1]
© Cambridge University Press & Assessment 2026
,
,
(c) Beans contain the enzyme catalase. The age of the bean could affect the concentration of
catalase it contains.
Catalase catalyses the breakdown of hydrogen peroxide to release water and oxygen gas.
Plan an investigation to determine if the age of the beans affects the volume of oxygen gas
produced by this reaction.
…
…
…
…
…
…
…
…
…
…
Question text
1
Catalase is an enzyme that catalyses the breakdown of hydrogen peroxide to form water and
oxygen. Catalase is found in potato tissue.
The oxygen produced during the breakdown of hydrogen peroxide forms a foam.
The height of the foam can be used as a measure of the activity of the catalase.
You are going to investigate how the surface area of potato tissue affects the activity of catalase.
Read all the instructions but DO NOT DO THEM until you have drawn a table for your
results in the space provided in 1(a)(ii).
You should use the safety equipment provided while you are doing the practical work.
step 1
Label the three test-tubes 1, 2 and 8. Put the test-tubes into the test-tube rack.
You are provided with three cubes of potato tissue that are 1 cm × 1 cm × 1 cm in size as
shown in Figure 1.1. The total surface area of one of these cubes is 6 cm 2 .
1 cm
1 cm
1 cm
Figure 1.1
step 2
Put one of the cubes of potato into the test-tube labelled 1.
step 3
Put one of the remaining cubes of potato onto the white tile. Use the ruler and scalpel
to measure and cut the cube of potato as shown in Figure 1.2. This will make two
equal-size pieces. The total surface area of the two pieces is 8 cm 2 .
cut here
0.5 cm 0.5 cm
Figure 1.2
© Cambridge University Press & Assessment 2026
,
,
step 4
Put both of the pieces of potato from step 3 into the test-tube labelled 2.
step 5
Put the remaining cube of potato onto the white tile. Use the ruler and scalpel to
measure and cut the cube of potato as shown in Figure 1.3. This will make eight
equal-size cubes.
0.5 cm 0.5 cm
cut here
0.5 cm
0.5 cm
cut here
0.5 cm
0.5 cm
cut here
Figure 1.3
(a) (i)
Calculate the total surface area of the eight cubes of potato made in step 5.
Space for working.
… cm 2
[2]
step 6
Put the eight cubes of potato into the test-tube labelled 8.
Use the syringe to put 10 cm 3 of hydrogen peroxide solution into each of
step 7
the test-tubes.
step 8
Start the stop-clock and wait for five minutes.
step 9
After five minutes, place the ruler against the outside of test-tube 1.
Measure the distance from the top of the liquid to the top of the foam.
Record this measurement in your table in 1(a)(ii).
step 10 Repeat step 9 using test-tubes 2 and 8.
© Cambridge University Press & Assessment 2026
,
,
(ii)
Prepare a table and record your results.
[4]
(iii)
State a conclusion for your results.
…
…
… [1]
(iv)
State two variables that were kept constant in this investigation.
1 …
2 …
[2]
(v)
Identify one safety hazard in this investigation.
…
…
… [1]
© Cambridge University Press & Assessment 2026
,
,
(vi)
Identify two possible sources of error present in steps 7 to 10 of this investigation.
Suggest an improvement for each of the errors that you have identified.
error 1 …
Question text
3
Amylase is an enzyme that catalyses the breakdown of starch to form reducing sugars.
Plan an investigation to determine the effect of pH on the activity of amylase.
Use iodine solution in your method.
…
…
…
…
…
…
…
…
…
…
…
…
… [6]
ĬÍĊ®Ġ´íÈõÏĪÅĊÞúµĂ×
,
,
Permission to reproduce items where third‑party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer‑related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
ĬÍĊ®Ġ´íÈõÏĪÅĊàúµĄ×
Question text
2
(a) The enzyme pectinase is used in the production of apple juice.
In an experiment, a student investigated the production of apple juice using five different
concentrations of pectinase solution.
For each concentration, the student:
•
put 100 g of crushed apple into a beaker
added 10 cm 3 of the pectinase solution to the crushed apple
•
•
left the crushed apple and enzyme mixture for 30 minutes at 40 °C
•
filtered the apple juice from the mixture
•
measured the volume of apple juice produced.
(i)
The temperature was maintained at 40 °C.
Describe how the student could maintain the crushed apple and enzyme mixture at a
constant temperature.
…
…
… [1]
(ii)
State two other variables that were kept constant in this investigation.
1 …
…
2 …
…
[2]
(b) The results of this investigation are shown in Table 2.1.
Table 2.1
percentage concentration
volume of apple juice
produced / cm 3
of the pectinase solution
0.1
4
0.2
6
0.4
12
0.8
22
1.6
22
ĬÙú¾Ġ´íÈõÏĪÅĊÝúµĀ×
,
,
(i)
Plot a line graph on the grid of the data in Table 2.1.
[4]
(ii)
Use your graph to estimate the volume of apple juice produced with a 0.5% pectinase
solution.
Show on your graph how you obtained your answer.
… cm 3
[2]
(iii)
Describe the effect of pectinase solution concentration on apple juice production.
…
…
… [1]
ĬÛú¾Ġ´íÈõÏĪÅĊÝüµĀ×
,
,
(iv)
Pectinase is used to produce apple juice commercially.
Suggest what extra data would be required to determine if a 0.8% pectinase solution is
the optimum concentration for the production of apple juice.
…
…
… [1]
(v)
Draw and label the apparatus the student could use to filter and measure the volume of
apple juice produced.
[3]
[Total: 14]
ĬÙú¾Ġ´íÈõÏĪÅĊàú·þ×
Question text
1
Potato cells contain the enzyme catalase. Catalase catalyses the breakdown of hydrogen peroxide
into water and oxygen gas. The oxygen gas forms a foam. The height of the foam indicates how
active the enzyme is.
You are going to investigate the effect of temperature on the activity of the enzyme catalase.
Read all the instructions but DO NOT DO THEM until you have drawn a table for your results
in the space provided in 1(a)(i).
You should use the safety equipment provided while you are doing the practical work.
Step 1
Label three test-tubes C, R and H and place them in the test-tube rack.
Use the large syringe to add 4 cm 3 of hydrogen peroxide solution from the beaker labelled
Step 2
hydrogen peroxide solution to each of the test-tubes labelled C, R and H.
Step 3
Place test-tube C into the beaker labelled cold water-bath.
Step 4
Leave test-tube R in the test-tube rack.
Step 5
Place test-tube H into the empty beaker labelled hot water-bath.
Step 6
Raise your hand when you are ready for hot water to be added to your hot water-bath.
Step 7
Start the stop-clock and leave the test-tubes for five minutes.
After five minutes, use the small syringe to put 1 cm 3 of the potato extract from the beaker
Step 8
labelled P into test-tube C. Start the stop-clock and observe the reaction for 30 seconds.
Step 9
After 30 seconds, measure the height of the foam produced in test-tube C in mm. Record
this measurement in your table in 1(a)(i).
Step 10 Repeat step 8 and step 9 for test-tube R and test-tube H.
ĬÕú¾Ġ´íÈõÏĪÅĊÞù¸þ×
,
,
(a) (i)
Prepare a table and record your results.
[4]
(ii)
State a conclusion for your results.
…
…
… [1]
(iii)
State the independent and dependent variables in the investigation.
independent variable …
…
dependent variable …
…
[2]
Ĭ×ú¾Ġ´íÈõÏĪÅĊÞû¸þ×
,
,
(iv)
Explain why test-tube C and test-tube H were kept in the water-baths for five minutes in
step 7.
…
…
… [1]
(v)
A student suggests repeating the investigation twice more.
Explain how this would give you more confidence in your results.
…
…
… [1]
(vi)
Potato extract can be prepared by cutting a potato into pieces and then grinding it with a
mortar and pestle and some water.
Describe a safety precaution that would reduce the hazards in producing potato extr
Question text
1
Amylase is an enzyme found in the human body that catalyses the breakdown of starch into
reducing sugars.
Tea contains a chemical called tannin which affects amylase activity in the body.
You are going to investigate the effect of tea on the enzyme amylase.
Read all the instructions but DO NOT DO THEM until you have drawn a table for your results
in the space provided in 1(a)(ii).
You should use the safety equipment provided while you are doing the practical work.
Step 1
Label three test‑tubes S1, S2 and S3.
Use a syringe to put 2 cm 3 of starch suspension into all three test‑tubes.
Step 2
Step 3
Label another three test‑tubes A, AT and T.
Use a clean syringe to put 2 cm 3 of amylase solution into test‑tube A and 2 cm 3 of
Step 4
amylase solution into test‑tube AT.
Use a clean syringe to put 2 cm 3 of tea into test‑tube AT and 2 cm 3 of tea into test‑tube T.
Step 5
Step 6
Raise your hand when you are ready for hot water to be added to the beaker labelled
water‑bath.
Step 7
Place all six test‑tubes into the hot water‑bath.
Step 8
Use the marker pen to label three sections on a white tile, as shown in Fig. 1.1.
A
AT
T
Fig. 1.1
ĬÕú¾Ġ´íÈõÏĪÅĊÝù¸þ×
,
,
Step 9
Add 10 drops of iodine solution to each section, as shown in Fig. 1.2.
white tile
A
AT
T
one drop of
iodine solution
Fig. 1.2
Step 10 Start the stop‑clock and pour the starch suspension in test‑tube S1 into test‑tube A.
Step 11 Use a pipette to immediately remove a drop of the mixture from test‑tube A and place it
onto the first drop of iodine solution in section A on the white tile.
Return any mixture still in the pipette to test‑tube A.
Step 12 Repeat step 11 every 30 seconds, until all 10 drops of iodine solution in section A have
been used. Reset the stop‑clock to zero.
Step 13 Repeat steps 10 to 12 using test‑tubes S2 and AT.
Step 14 Repeat steps 10 to 12 using test‑tubes S3 and T.
Ĭ×ú¾Ġ´íÈõÏĪÅĊÝû¸þ×
,
,
(a) For this investigation, you need to identify when all of the starch has been broken down in
each test‑tube.
(i)
Describe how you can tell if the starch has been broken down.
… [1]
(ii)
Prepare a table for your results.
Include in your table the time taken for starch to be broken down in all three test‑tubes.
If starch remained after testing with all 10 drops, record this as >300.
[4]
(iii)
State what can be concluded about the effect of tea on amylase activity.
…
…
… [1]
(iv)
State the independent variable in this investigation.
… [1]
(v)
Test‑tube T did not contain amylase and was used as a control.
Suggest a reason for including a control in this investigation.
…
…
… [1]
ĬÕú¾Ġ´íÈõÏĪÅĊßù¸Ā×
,
,
(vi)
Explain why the test‑tubes were placed in a water‑bath in step 7 before the contents of
the test‑tubes were mixed in step 10.
…
Question text
1
Catalase is an enzyme that catalyses the breakdown of hydrogen peroxide to form water and
oxygen.
You are going to investigate the activity of catalase in tissues from two different plants.
The oxygen produced during the breakdown of hydrogen peroxide forms a foam.
The height of the foam can be used as a measure of the activity of the catalase present in plant
tissue.
Read all the instructions but DO NOT DO THEM until you have drawn a table for your results
in the space provided in 1(a)(i).
You should use the safety equipment provided while you are doing the practical work.
Label one test‑tube P and the other test‑tube A.
Step 1
Step 2
Put the potato cylinder onto the white tile. Use the scalpel and ruler to measure and cut
the potato cylinder so that it is 2 cm in length.
Step 3
Cut the 2 cm cylinder into five equal pieces. Each piece should be approximately 4 mm in
length, as shown in Fig. 1.1.
cut to form five pieces
4 mm
2 cm long potato cylinder
Fig. 1.1
Put all five potato pieces into test‑tube P. Place the test‑tube in the test‑tube rack.
Step 4
Repeat steps 2 to 4 using the apple cylinder and the test‑tube labelled A.
Step 5
Use the syringe to put 15 cm 3 of hydrogen peroxide solution into test‑tube P.
Step 6
Step 7
Start the stop‑clock and wait for five minutes.
After five minutes, place the ruler against the outside of test‑tube P.
Step 8
Measure the height of the foam. Record this measurement in your table in 1(a)(i).
Repeat steps 6 to 8 with test‑tube A.
Step 9
(a) (i)
Prepare a table to record your results.
[4]
(ii)
State a conclusion for your results.
…
…
… [1]
(iii)
State the independent variable in this investigation.
…
… [1]
(iv)
State two variables that were kept constant in this investigation.
1 …
2 …
[2]
(v)
Identify one possible source of error in step 8 and describe an improvement to the
method that would eliminate this error.
error in step 8 …
…
…
improvement …
…
…
[2]
(vi)
Identify one safety hazard when carrying out this investigation and describe how the risk
of this hazard could be reduced.
safety hazard …
…
Question text
1
You are going to investigate the effect of temperature on the activity of amylase.
Amylase is an enzyme that catalyses the breakdown of starch to form reducing sugars.
Read all the instructions but DO NOT DO THEM until you have drawn a table for your results
in the space provided in 1(a)(i).
You should use the safety equipment provided while you are doing the practical work.
Step 1
Use the pen to draw a line down the middle of the spotting tile. Write the numbers and
the letters C and H on the spotting tile, as shown in Fig. 1.1.
1
2
1
2
dimple
3
4
3
4
5
6
5
6
C
H
Fig. 1.1
Step 2
Place one drop of iodine solution into each of the labelled dimples on the spotting tile.
Label one test-tube C and the other test-tube H. Place the test-tubes in the test-tube
Step 3
rack.
Use the syringe to put 2 cm 3 of starch suspension into test-tube C and into test-tube H.
Step 4
Place test-tube C and the test-tube labelled amylase C into the water in beaker C.
Step 5
Start the stop-clock.
After three minutes, stop the stop-clock and pour the contents of test-tube amylase C
Step 6
into test-tube C.
Restart the stop-clock, wait for 30 seconds and then continue to step 7.
Use a pipette to remove a sample of liquid from test-tube C.
Step 7
Place two drops of this sample into the dimple labelled C1 on your spotting tile. Return
the rest of the sample in the pipette to test-tube C.
Observe the colour of the liquid in dimple C1. Record this colour in your table in 1(a)(i).
Step 8
Repeat step 7 and step 8 at 30-second intervals, using the dimples labelled C2, C3, C4,
Step 9
C5 and C6.
Step 10 Raise your hand when you are ready for hot water to be added to beaker H.
Step 11 Place test-tube H and test-tube amylase H into the hot water in beaker H. Reset the
stop-clock to zero. Start the stop-clock again.
Step 12 After three minutes, stop the stop-clock and pour the contents of test-tube amylase H
into test-tube H. Restart the stop-clock, wait for 30 seconds and then continue to step 13.
Step 13 Use a pipette to remove a sample of the liquid from test-tube H.
Place two drops of this sample into the dimple labelled H1 on your spotting tile. Return
the rest of the sample in the pipette to test-tube H.
Step 14 Observe the colour of the liquid in dimple H1. Record this colour in your table in
1(a)(i).
Step 15 Repeat step 13 and step 14 at 30-second intervals, using the dimples labelled H2, H3,
H4, H5 and H6.
(a) (i)
Prepare a table for your results.
[4]
(ii)
State the colour of iodine solution when starch is present.
… [1]
(iii)
State a conclusion for your results.
…
…
… [1]
(iv)
State the independent variable in this investigation.
… [1]
(v)
State two variables that were kept constant in this investigation.
1 …
…
2 …
…
[2
Question text
1
You are going to investigate the effect of hydrogen peroxide concentration on the activity of
catalase.
Catalase is an enzyme found in yeast cells. The enzyme catalyses the breakdown of hydrogen
peroxide to form water and oxygen. The reaction releases heat.
You are going to compare the activity of catalase in yeast cells in two different concentrations of
hydrogen peroxide solution by measuring the change in temperature during the reaction.
Read all the instructions but DO NOT DO THEM until you have drawn a table for your results
in the space provided in 1(a)(i).
You should use the safety equipment provided while you are doing the practical work.
Step 1
Cover the outside of each of the test-tubes with a piece of foil. Do not cover the openings
at the top of the test-tubes.
Attach a sticky label to the foil on each test-tube. Label one test-tube A and the other
Step 2
test-tube B. Put the foil-covered test-tubes into the test-tube rack.
Use the large syringe to put 10 cm 3 of hydrogen peroxide solution into test-tube A.
Step 3
Measure the temperature of the hydrogen peroxide solution in test-tube A. Record this
Step 4
measurement as the temperature at 0 minutes in your table in 1(a)(i).
Use the glass rod to stir the yeast suspension. Use the small syringe to add 1 cm 3 of
Step 5
yeast suspension to the hydrogen peroxide solution in test-tube A.
Immediately start the stop-clock.
Measure the temperature of the hydrogen peroxide solution in test-tube A every minute
Step 6
for five minutes. Record the measurements in your table in 1(a)(i).
Use the large syringe to put 5 cm 3 of hydrogen peroxide solution and 5 cm 3 of distilled
Step 7
water into test-tube B.
Repeat steps 4, 5 and 6 using test-tube B.
Step 8
(a) (i)
Prepare a table to record your results.
[4]
(ii)
Using your results, identify the highest temperature and the lowest temperature in each
test-tube.
Use these values to calculate the maximum temperature change in each test-tube.
Space for working.
maximum temperature change in test-tube A … °C
maximum temperature change in test-tube B … °C
[2]
(iii)
State a conclusion for your results.
…
…
… [1]
(iv)
State the variable that was measured (dependent variable) in this investigation.
…
… [1]
(b) (i)
The test-tubes were covered with foil in step 1.
Predict and explain the effect on the results of not covering the test-tubes with foil.
…
…
…
…
… [2]
(ii)
State one variable, other than covering both test-tubes with foil, that was kept cons
Question text
1
Rice contains starch. Amylase is an enzyme that catalyses the breakdown of starch to form
reducing sugars.
You are going to investigate the effect of amylase on cooked rice.
Read all the instructions but DO NOT CARRY THEM OUT until you have drawn a table for
your results in the space provided in 1(a)(i).
You should use the safety equipment provided while you are carrying out the practical work.
Label one empty test-tube W10 and label the other empty test-tube A10.
Step 1
Put the test-tubes in the empty beaker labelled 80 °C water-bath.
Step 2
Label one of the large test-tubes containing rice W and the other large test-tube
Step 3
containing rice A.
Put both large test-tubes containing rice in the empty beaker labelled 40 °C water-bath.
Step 4
Raise your hand when you are ready for warm water to be added to the 40 °C water-bath.
Step 5
Use the measuring cylinder to add 20 cm 3 of distilled water to the rice in the test-tube
Step 6
labelled W.
Use the measuring cylinder to add 20 cm 3 of amylase solution to the rice in the test-
Step 7
tube labelled A.
Start the stop-clock and leave the test-tubes of rice in the 40 °C water-bath for 10 minutes.
Step 8
While you are waiting, carry out step 9.
Use the syringe to add 2 cm 3 of Benedict’s solution to each of the empty test-tubes, W10
Step 9
and A10. Put the test-tubes back in the empty beaker labelled 80 °C water-bath.
Step 10 After 10 minutes (step 8), put the stopper into test-tube W and invert the test-tube three
times. Remove the stopper.
Step 11 Use a clean pipette to remove 2 cm 3 of the liquid surrounding the rice in test-tube W. Put
the 2 cm 3 of liquid into test-tube W10. Put test-tube W10 back into the beaker labelled
80 °C water-bath.
Step 12 Repeat steps 10 and 11 with test-tubes A and A10.
Step 13 Raise your hand when you are ready for hot water to be added to the beaker labelled
80 °C water-bath.
Step 14 Leave test-tubes W10 and A10 in the 80 °C water-bath for 10 minutes. While you are
waiting continue with the other questions.
Step 15 After 10 minutes, record the colour of the liquid in test-tubes W10 and A10 in the table
you have prepared in 1(a)(i).
(a) (i)
Prepare a table to record your results.
[3]
(ii)
State a conclusion for your results.
…
…
… [1]
(iii)
State one variable that was kept constant in this investigation.
… [1]
(iv)
State the purpose of adding distilled water to the test-tube of cooked rice labelled W.
…
…
… [1]
(v)
It was important that step 6 was carried out before step 7.
Predict the effect on the results if step 7 was carried out before step 6.
…
…
… [1]
(vi)
The temperature of the 40 °C water-bath w
Question text
2
Fig. 2.1 is a photograph of the cut surface of half an apple.
X
Y
magnification ×1.2
Fig. 2.1
(a) (i)
Make a large drawing of the apple shown in Fig. 2.1.
[4]
(ii)
Measure the length of line XY on Fig. 2.1.
length of line XY … mm
Calculate the actual width of the apple using the formula and your measurement.
length of line XY
magnification =
actual width of the apple
Give your answer to the nearest whole number.
Space for working.
… mm
[3]
(b) Apples can be used to make juice. The enzyme pectinase can increase the volume of juice
that is released from each apple.
A scientist carried out an investigation to find out which concentration of the pectinase solution
gave the maximum volume of juice.
The results from this investigation are shown in Table 2.1.
Table 2.1
volume of apple juice collected in one hour / cm 3
percentage
concentration
of the pectinase
trial 1
trial 2
trial 3
average
solution
0.0
7
7
6
6.7
2.5
11
10
2
10.5
5.0
17
14
13
14.7
7.5
24
22
25
23.7
10.0
25
24
21
23.3
(i)
Identify the variable that was changed (independent variable) by the scientist in this
investigation.
… [1]
(ii)
The scientist decided not to include the trial 3 result for the 2.5% pectinase solution
when they calculated the average.
Explain why.
…
…
… [1]
(iii)
Describe how to test a sample of apple juice to show the presence of reducing sugars.
Give the result of a positive test.
…
…
…
…
…
…
… [3]
(c) Starch in apple juice makes the juice appear cloudy. The enzyme amylase can be used to
remove the starch. This makes the apple juice clear.
Amylase catalyses the breakdown of starch.
Plan an investigation to determine the optimum (best) temperature for amylase activity in a
sample of apple juice.
…
…
…
…
…
Question text
1
Catalase is an enzyme found in living cells. It catalyses the break-down of hydrogen peroxide to
form water and oxygen.
You are going to investigate the effect of catalase concentration on the rate of oxygen production.
You have been provided with a celery extract which contains catalase.
Read all the instructions but DO NOT CARRY THEM OUT until you have drawn a table for
your results in the space provided in 1(a)(ii).
You should use the safety equipment provided while you are carrying out the practical work.
Label five test-tubes A, B, C, D and E. Put the test-tubes into the test-tube rack.
Step 1
Use a measuring cylinder to pour 10 cm 3 of celery extract into test-tube A.
Step 2
Use the measuring cylinder to transfer 5 cm 3 of celery extract from test-tube A to test-
Step 3
tube B.
Use the measuring cylinder to add 5 cm 3 of distilled water to test-tube B. Place a stopper
in test-tube B and shake it three times.
Remove the stopper. Use the measuring cylinder to transfer 5 cm 3 of the liquid in test-
Step 4
tube B to test-tube C.
Use the measuring cylinder to add 5 cm 3 of distilled water to test-tube C. Place a stopper
in test-tube C and shake it three times.
Remove the stopper. Use the measuring cylinder to transfer 5 cm 3 of the liquid in test-
Step 5
tube C to test-tube D.
Use the measuring cylinder to add 5 cm 3 of distilled water to test-tube D. Place a stopper
in test-tube D and shake it three times.
Remove the stopper. Use the measuring cylinder to transfer 5 cm 3 of the liquid in test-
Step 6
tube D to test-tube E.
Use the measuring cylinder to add 5 cm 3 of distilled water to test-tube E. Place a stopper
in test-tube E and shake it three times. Remove the stopper.
(a) (i)
Table 1.1 shows the concentration of the celery extract in test-tubes A to E.
Table 1.1
percentage
test-tube
concentration of
celery extract
A
100.00
B
50.00
C
…
D
12.50
E
6.25
Complete Table 1.1 by calculating and writing in the percentage concentration of celery
extract in test-tube C.
[1]
Pour a small amount of the celery extract from test-tube A onto the watch glass, as
Step 7
shown in Fig. 1.1.
watch glass
celery extract
Fig. 1.1
Use the forceps to place one of the paper discs into the celery extract in the watch glass.
Step 8
Step 9
Use the ruler to measure 2 cm from the top (open end) of the remaining unlabelled
test-tube. Mark this distance by drawing a line on the test-tube with the marker pen.
Step 10 Use the forceps to remove the paper disc from the watch glass. Place the paper disc into
the test-tube you prepared in step 9. Push the paper disc to the bottom of the test-tube
with the glass rod.
Step 11 Carefully pour hydrogen peroxide solution into the test-tube until it reaches the line
you marked on the test-tube in step 9. Immediately start the stop-clock and observe the
paper disc rising.
Stop the stop-clock when the paper disc reaches the surface of the hydrogen peroxide
solution.
Record the time taken for the disc to rise, in your table in 1(a)(ii). Record the time in
seconds. If the paper disc has not reached the surface of the hydrogen peroxide solution
after three minutes, stop the stop-clock and record the time as >180 in your table.
Step 12 Pour the hydrogen peroxide solution and paper disc into the beaker labelled waste.
Empty the contents of the watch glass into the waste beaker. Wipe the watch glass with
a paper towel.
Step 13 Repeat steps 7 to 12 using the celery extract in test-tubes B, C, D and E.
(ii)
Prepare a table to record your results.
[4]
(iii)
State a conclusion for this investigation.
…
…
…