Enzymes – IGCSE Biology (0610)
4 questions · Clear filters
Question text
3
Amylase is an enzyme that catalyses the breakdown of starch to form reducing sugars.
Plan an investigation to determine the effect of pH on the activity of amylase.
Use iodine solution in your method.
…
…
…
…
…
…
…
…
…
…
…
…
… [6]
ĬÍĊ®Ġ´íÈõÏĪÅĊÞúµĂ×
,
,
Permission to reproduce items where third‑party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer‑related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
ĬÍĊ®Ġ´íÈõÏĪÅĊàúµĄ×
Question text
1
Amylase is an enzyme found in the human body that catalyses the breakdown of starch into
reducing sugars.
Tea contains a chemical called tannin which affects amylase activity in the body.
You are going to investigate the effect of tea on the enzyme amylase.
Read all the instructions but DO NOT DO THEM until you have drawn a table for your results
in the space provided in 1(a)(ii).
You should use the safety equipment provided while you are doing the practical work.
Step 1
Label three test‑tubes S1, S2 and S3.
Use a syringe to put 2 cm 3 of starch suspension into all three test‑tubes.
Step 2
Step 3
Label another three test‑tubes A, AT and T.
Use a clean syringe to put 2 cm 3 of amylase solution into test‑tube A and 2 cm 3 of
Step 4
amylase solution into test‑tube AT.
Use a clean syringe to put 2 cm 3 of tea into test‑tube AT and 2 cm 3 of tea into test‑tube T.
Step 5
Step 6
Raise your hand when you are ready for hot water to be added to the beaker labelled
water‑bath.
Step 7
Place all six test‑tubes into the hot water‑bath.
Step 8
Use the marker pen to label three sections on a white tile, as shown in Fig. 1.1.
A
AT
T
Fig. 1.1
ĬÕú¾Ġ´íÈõÏĪÅĊÝù¸þ×
,
,
Step 9
Add 10 drops of iodine solution to each section, as shown in Fig. 1.2.
white tile
A
AT
T
one drop of
iodine solution
Fig. 1.2
Step 10 Start the stop‑clock and pour the starch suspension in test‑tube S1 into test‑tube A.
Step 11 Use a pipette to immediately remove a drop of the mixture from test‑tube A and place it
onto the first drop of iodine solution in section A on the white tile.
Return any mixture still in the pipette to test‑tube A.
Step 12 Repeat step 11 every 30 seconds, until all 10 drops of iodine solution in section A have
been used. Reset the stop‑clock to zero.
Step 13 Repeat steps 10 to 12 using test‑tubes S2 and AT.
Step 14 Repeat steps 10 to 12 using test‑tubes S3 and T.
Ĭ×ú¾Ġ´íÈõÏĪÅĊÝû¸þ×
,
,
(a) For this investigation, you need to identify when all of the starch has been broken down in
each test‑tube.
(i)
Describe how you can tell if the starch has been broken down.
… [1]
(ii)
Prepare a table for your results.
Include in your table the time taken for starch to be broken down in all three test‑tubes.
If starch remained after testing with all 10 drops, record this as >300.
[4]
(iii)
State what can be concluded about the effect of tea on amylase activity.
…
…
… [1]
(iv)
State the independent variable in this investigation.
… [1]
(v)
Test‑tube T did not contain amylase and was used as a control.
Suggest a reason for including a control in this investigation.
…
…
… [1]
ĬÕú¾Ġ´íÈõÏĪÅĊßù¸Ā×
,
,
(vi)
Explain why the test‑tubes were placed in a water‑bath in step 7 before the contents of
the test‑tubes were mixed in step 10.
…
Question text
1
You are going to investigate the effect of temperature on the activity of amylase.
Amylase is an enzyme that catalyses the breakdown of starch to form reducing sugars.
Read all the instructions but DO NOT DO THEM until you have drawn a table for your results
in the space provided in 1(a)(i).
You should use the safety equipment provided while you are doing the practical work.
Step 1
Use the pen to draw a line down the middle of the spotting tile. Write the numbers and
the letters C and H on the spotting tile, as shown in Fig. 1.1.
1
2
1
2
dimple
3
4
3
4
5
6
5
6
C
H
Fig. 1.1
Step 2
Place one drop of iodine solution into each of the labelled dimples on the spotting tile.
Label one test-tube C and the other test-tube H. Place the test-tubes in the test-tube
Step 3
rack.
Use the syringe to put 2 cm 3 of starch suspension into test-tube C and into test-tube H.
Step 4
Place test-tube C and the test-tube labelled amylase C into the water in beaker C.
Step 5
Start the stop-clock.
After three minutes, stop the stop-clock and pour the contents of test-tube amylase C
Step 6
into test-tube C.
Restart the stop-clock, wait for 30 seconds and then continue to step 7.
Use a pipette to remove a sample of liquid from test-tube C.
Step 7
Place two drops of this sample into the dimple labelled C1 on your spotting tile. Return
the rest of the sample in the pipette to test-tube C.
Observe the colour of the liquid in dimple C1. Record this colour in your table in 1(a)(i).
Step 8
Repeat step 7 and step 8 at 30-second intervals, using the dimples labelled C2, C3, C4,
Step 9
C5 and C6.
Step 10 Raise your hand when you are ready for hot water to be added to beaker H.
Step 11 Place test-tube H and test-tube amylase H into the hot water in beaker H. Reset the
stop-clock to zero. Start the stop-clock again.
Step 12 After three minutes, stop the stop-clock and pour the contents of test-tube amylase H
into test-tube H. Restart the stop-clock, wait for 30 seconds and then continue to step 13.
Step 13 Use a pipette to remove a sample of the liquid from test-tube H.
Place two drops of this sample into the dimple labelled H1 on your spotting tile. Return
the rest of the sample in the pipette to test-tube H.
Step 14 Observe the colour of the liquid in dimple H1. Record this colour in your table in
1(a)(i).
Step 15 Repeat step 13 and step 14 at 30-second intervals, using the dimples labelled H2, H3,
H4, H5 and H6.
(a) (i)
Prepare a table for your results.
[4]
(ii)
State the colour of iodine solution when starch is present.
… [1]
(iii)
State a conclusion for your results.
…
…
… [1]
(iv)
State the independent variable in this investigation.
… [1]
(v)
State two variables that were kept constant in this investigation.
1 …
…
2 …
…
[2
Question text
1
You are going to investigate the effect of hydrogen peroxide concentration on the activity of
catalase.
Catalase is an enzyme found in yeast cells. The enzyme catalyses the breakdown of hydrogen
peroxide to form water and oxygen. The reaction releases heat.
You are going to compare the activity of catalase in yeast cells in two different concentrations of
hydrogen peroxide solution by measuring the change in temperature during the reaction.
Read all the instructions but DO NOT DO THEM until you have drawn a table for your results
in the space provided in 1(a)(i).
You should use the safety equipment provided while you are doing the practical work.
Step 1
Cover the outside of each of the test-tubes with a piece of foil. Do not cover the openings
at the top of the test-tubes.
Attach a sticky label to the foil on each test-tube. Label one test-tube A and the other
Step 2
test-tube B. Put the foil-covered test-tubes into the test-tube rack.
Use the large syringe to put 10 cm 3 of hydrogen peroxide solution into test-tube A.
Step 3
Measure the temperature of the hydrogen peroxide solution in test-tube A. Record this
Step 4
measurement as the temperature at 0 minutes in your table in 1(a)(i).
Use the glass rod to stir the yeast suspension. Use the small syringe to add 1 cm 3 of
Step 5
yeast suspension to the hydrogen peroxide solution in test-tube A.
Immediately start the stop-clock.
Measure the temperature of the hydrogen peroxide solution in test-tube A every minute
Step 6
for five minutes. Record the measurements in your table in 1(a)(i).
Use the large syringe to put 5 cm 3 of hydrogen peroxide solution and 5 cm 3 of distilled
Step 7
water into test-tube B.
Repeat steps 4, 5 and 6 using test-tube B.
Step 8
(a) (i)
Prepare a table to record your results.
[4]
(ii)
Using your results, identify the highest temperature and the lowest temperature in each
test-tube.
Use these values to calculate the maximum temperature change in each test-tube.
Space for working.
maximum temperature change in test-tube A … °C
maximum temperature change in test-tube B … °C
[2]
(iii)
State a conclusion for your results.
…
…
… [1]
(iv)
State the variable that was measured (dependent variable) in this investigation.
…
… [1]
(b) (i)
The test-tubes were covered with foil in step 1.
Predict and explain the effect on the results of not covering the test-tubes with foil.
…
…
…
…
… [2]
(ii)
State one variable, other than covering both test-tubes with foil, that was kept cons