Past paper – A Level Biology (9700)
Cambridge International AS & A Level · 9700
Biology · Paper 38
Oct/Nov 2025 · 9700/38/O/N/25
Answer on paper, open each mark scheme and give yourself marks, then open the Summary.
Question text
1
Yeast cells contain enzymes that hydrolyse sucrose into reducing sugars, as shown in Fig. 1.1.
enzymes in yeast cells
reducing sugars
sucrose
Fig. 1.1
You will investigate the activity of the enzymes in yeast cells that are immobilised in sodium
alginate beads and yeast cells that are in a suspension (‘free’ yeast cells).
You are provided with the materials shown in Table 1.1.
Table 1.1
volume / cm 3
labelled
contents
hazard
Y
yeast cell suspension
low
20
A
sodium alginate solution
low
20
C
calcium chloride solution
low
20
S
sucrose solution
low
50
Benedict’s
Benedict’s solution
harmful irritant
20
W
distilled water
low
50
If any solution comes into contact with your skin, wash off immediately with cold water.
It is recommended that you wear suitable eye protection.
You will need to:
•
immobilise some of the yeast cells in sodium alginate
•
put the immobilised yeast cells and some ‘free’ yeast cells into sucrose solution
•
test both solutions for reducing sugars
•
compare the activity of immobilised yeast cells and ‘free’ yeast cells.
ĬÍĊ®Ġ´íÈõÏĪÅĊßù·þ×
,
,
Investigating the activity of the enzymes in immobilised yeast cells
Carry out step 1 to step 20.
Put 10 cm 3 of sodium alginate, A, into a beaker.
step 1
Stir the yeast cell suspension, Y, and put 10 cm 3 of Y into the beaker containing A. Mix
step 2
well.
Use a 1 cm 3 syringe to collect 1 cm 3 of the mixture of A and Y. Wipe the outside of the
step 3
syringe.
step 4
Hold this syringe over the beaker containing calcium chloride solution, C, as shown in
Fig. 1.2.
step 5
Slowly press down on the plunger so that a drop of the mixture is released into C. The
drop will form a bead.
step 6
Repeat step 5 until all of the mixture in the syringe has been formed into beads.
slowly press down to release
one drop at a time
plunger
barrel of syringe
mixture of A and Y
one drop released
calcium chloride solution, C
Fig. 1.2
step 7
Leave the beads in the beaker for at least 5 minutes.
step 8
Set up a boiling water-bath ready for step 18.
step 9
Label a beaker B.
step 10 Put 20 cm 3 of sucrose solution, S, into the beaker labelled B.
step 11 Label 5 test-tubes 1, 2, 3, 4 and 5.
ĬÏĊ®Ġ´íÈõÏĪÅĊßû·þ×
,
,
step 12 Put 1 cm 3 of Benedict’s into each of the test-tubes.
step 13 After at least 5 minutes (step 7), separate the beads from solution C using the apparatus
shown in Fig. 1.3.
funnel
beads
filter paper
Fig. 1.3
After step 14 you will remove a sample from B every minute for 5 minutes.
step 14 Put all of the beads into the beaker labelled B. Stir and then start timing.
step 15 At 1 minute, stir the contents of beaker B and use a syringe to transfer 1 cm 3 of the
solution surrounding the beads into the test-tube labelled 1.
step 16 At 2 minutes, stir the contents of beaker B and use a syringe to transfer 1 cm 3 of the
solution surrounding the beads into the test-tube labelled 2.
step 17 Continue taking samples at 3, 4 and 5 minutes using the test-tubes labelled 3, 4 and 5.
step 18 Put test-tube 1 into the boiling water-bath and measure the time to the first colour change.
Record your result in (a)(i).
If there is no colour change after 60 seconds, stop timing and record the time as ‘more
than 60’.
step 19 Remove the test-tube from the boiling water-bath.
step 20 Repeat step 18 and step 19 for the test-tubes labelled 2, 3, 4 and 5.
Investigating the activity of the enzymes in ‘free’ yeast cells
To investigate the activity of the enzymes in ‘free’ yeast cells, you will need to test the samples
with Benedict’s solution immediately after the sample is taken.
The water-bath should be boiling throughout this part of the investigation.
Carry out step 21 to step 32.
step 21 Label a beaker F.
step 22 Put 20 cm 3 of sucrose solution, S, into the beaker labelled F.
step 23 Label 5 clean test-tubes 1, 2, 3, 4 and 5.
ĬÍĊ®Ġ´íÈõÏĪÅĊÝù·Ā×
,
,
step 24 Put 1 cm 3 of Benedict’s into each of the test-tubes.
step 25 Stir the yeast cell suspension, Y, and put 0.5 cm
Question text
2
N1 is a slide of a stained transverse section through a plant organ.
(a) (i)
Draw a large plan diagram of the whole section on N1. Use a sharp pencil.
Use one ruled label line and label to identify the phloem.
[5]
ĬÑĊ®Ġ´íÈõÏĪÅĊßû¸þ×
,
,
(ii)
Observe the cortex on the section of the plant organ on N1. The cortex is the layer
beneath the epidermis.
Select a group of four adjacent cortex cells.
Each cortex cell must touch at least two of the other cortex cells.
•
Make a large drawing of this group of four cortex cells.
•
Use one ruled label line and label to identify the cell wall of one cortex cell.
[5]
ĬÓĊ®Ġ´íÈõÏĪÅĊßù¸þ×
,
,
(b) Fig. 2.1 is a photomicrograph of a stained transverse section of the same organ from a
different plant to N1.
Fig. 2.1
Identify three observable differences, other than colour, between the section on N1 and the
section in Fig. 2.1.
Record these three observable differences in Table 2.1.
Table 2.1
feature
N1
Fig. 2.1
1
2
3
[4]
ĬÓĊ®Ġ´íÈõÏĪÅĊÝù¸Ā×
,
,
(c) Fig. 2.2 is the same photomicrograph as that shown in Fig. 2.1.
A black dot has been placed at the centre of the section.
310 μm
Fig. 2.2
(i)
Determine the mean diameter of the section in Fig. 2.2.
Show your working and include units.
mean diameter = …
[2]
(ii)
Use the scale bar to calculate the mean actual diameter of the section in Fig. 2.2.
Show your working and include units.
mean actual diameter = …
[2]
ĬÍĊ®Ġ´íÈõÏĪÅĊÞúµĂ×
,
,
(iii)
Use the mean actual diameter calculated in (c)(ii) to calculate the magnification of
Fig. 2.2.
Show your working and give your answer to the nearest whole number.
magnification = …
[2]
[Total: 20]
ĬÏĊ®Ġ´íÈõÏĪÅĊÞüµĂ×
,
,
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
ĬÍĊ®Ġ´íÈõÏĪÅĊàúµĄ×