Cell structure – A Level Biology (9700)
1 question · Clear filters
Question text
2
Tumours may be described as benign or malignant. Malignant tumours can lead to greater
complications for the person with the tumour.
Early identification of tumours, particularly malignant tumours, is important for effective treatment.
Benign tumour cells and malignant tumour cells can look similar when viewed using a light
microscope.
Some scientists wanted to develop a diagnostic test to identify tumour cells as benign or malignant.
The scientists investigated whether the diameter of the cell nucleus could be used to identify the
type of tumour cell as benign or malignant.
The scientists used a light microscope with a calibrated eyepiece graticule to measure the
diameter of the nuclei of stained tumour cells.
Fig. 2.1 shows a photomicrograph of stained tumour cells viewed using a light microscope.
An eyepiece graticule was placed across the nucleus of one of the tumour cells.
0
10
90
80
70
cell surface
60
membrane
50
nucleus
40
30
cell X
20
eyepiece
10
graticule
0
image
magnification
×400
Fig. 2.1
The calibration of the eyepiece graticule scale is:
one eyepiece graticule division = 320 nm
,
,
(a) Use the calibration of the eyepiece graticule scale to calculate the actual diameter of the
nucleus of cell X, shown in Fig. 2.1.
Show your working and state your answer in µm.
actual diameter of the nucleus of cell X = … µm [3]
(b) For the investigation into whether the diameter of the nucleus could be used to identify the
type of tumour cell, tumours of the thyroid gland (an endocrine gland) were used.
For the diagnostic test the scientists carried out a procedure using two different stains.
step 1
50 people diagnosed with benign tumours and 24 people diagnosed with malignant
tumours were selected.
step 2 A sample of tumour cells was removed from the thyroid gland of each person.
step 3 The cells were stained with either Papanicolaou stain (Pap) or haematoxylin and
eosin stain (H&E).
step 4 Samples were viewed using a light microscope with a magnification of ×400.
step 5 In each sample, the diameters of 100 nuclei were measured.
step 6 The measurements were made by one of the scientists who did not know the type of
tumour cell they were measuring.
,
,
Table 2.1 shows the results of the investigation.
Table 2.1
standard
standard
category
mean nuclear
diameter / µ m
deviation / µ m
error / µ m
7.3
total benign cells (50 people) 5000 cells:
± 0.8
± 0.011
•
Pap‑stained cells (41 people) 4100 cells
7.3
± 0.7
± 0.011
•
H&E‑stained cells (9 people) 900 cells
7.2
± 1.0
± 0.033
9.0
± 0.6
± 0.122
total malignant cells (24 people) 2400 cells:
•
Pap‑stained cells (18 people) 1800 cells
9.0
± 0.7
± 0.016
•
H&E‑stained cells (6 people) 600 cells
8.8
± 0.5
± 0.020
(i)
Suggest how the scientists can standardise the method of measuring the diameter of
the 100 nuclei in step 5, so that valid comparisons can be made between benign and
malignant tumour cells.
…
…
… [1]
(ii)
Identify one variable that the scientists have standardised in step 1 to step 6, other than
details of the method of measurement of the nuclei.
…
…
… [1]
(iii)
The scientists used a t‑test to compare the m