Chemistry · October/November 2023 · Examiner report · Unit 3

Edexcel IAL Chemistry examiner report for Unit 3, October/November 2023 — WCH13/01, file wch13-01-pef-20240118.pdf.

Advertisement
Loading the paper…
Text of this paper

Examiners’ Report
Principal Examiner Feedback
October 2023
Pearson Edexcel International Advanced
Subsidiary Level In Chemistry (WCH13)
Paper 01: Practical Skills in Chemistry I

Edexcel and BTEC Qualifications

Edexcel and BTEC qualifications are awarded by Pearson, the UK’s largest awarding
body. We provide a wide range of qualifications including academic, vocational,
occupational and specific programmes for employers. For further information visit our
qualifications websites at www.edexcel.com or www.btec.co.uk. Alternatively, you can
get in touch with us using the details on our contact us page at
www.edexcel.com/contactus.

Pearson: helping people progress, everywhere

Pearson aspires to be the world’s leading learning company. Our aim is to help everyone
progress in their lives through education. We believe in every kind of learning, for all
kinds of people, wherever they are in the world. We’ve been involved in education for
over 150 years, and by working across 70 countries, in 100 languages, we have built
an international reputation for our commitment to high standards and raising
achievement through innovation in education. Find out more about how we can help
you and your students at: www.pearson.com/uk

October 2023
Question Paper Log Number: P75062A
Publications Code: WCH13_01_ER_2310
All the material in this publication is copyright.
© Pearson Education Ltd 2023

Introduction
The quality of responses on this paper was very varied; some candidates showed a thorough
knowledge and understanding of the practical work associated with this Specification while others
seemed uncertain of some of the most elementary chemistry and unfamiliar with the core practicals
referred to in the specification. Candidates were most assured in dealing with the calculations and
the related graphical techniques and they were often able to deal competently with descriptive work
based on familiar ideas. However, explaining or deducing the reasons for the use of particular
techniques or processes proved much more challenging and many candidates were more likely to
rely on generalisations than to address the specific points raised. A significant number of candidates
hampered their prospects by appearing to attempt questions without reading them in full and advice
given in past series about practising the drawing of diagrams and not rounding intermediate values
in calculations does not seem to have been fully absorbed.

Question 1
1(a)(i) There were many word perfect descriptions of the procedure for the flame test; the most
common error was failing to put the sample into the flame. Some candidates neglected to specify a
metal for the flame test wire or gave an incorrect acid while others referred to use of the cation
rather than the sample.
1(a)(ii) The flame colours of sodium and potassium ions were well-known but identifying the cation
responsible for the pale green flame colour proved more challenging. Many candidates who realised
that the colour indicated the presence of a barium compound showed the ion with a single positive
charge.
1(b)(i) The identity of the halide ions was very well known, with most candidates giving the
formulae. Identifying the ions as halogens rather than halides was perhaps the most common error.
1(b)(ii)The majority of the candidates who understood what the question required chose to use
ammonia to test the precipitates and there were plenty of concise and accurate responses which
gained full marks. The most common errors were the omission or confusion of ‘dilute’ and
‘concentrated’ and mixing up the solubilities of silver bromide and silver iodide. Candidates who
used concentrated sulfuric acid often scored full marks although a number omitted ‘concentrated’.
A significant number of candidates described the test with silver nitrate given at the start of the
question and then stated the colours of the precipitates, a response that gained one mark.
Question 2
2(a) Few candidates demonstrated a reasonable appreciation of how to draw a two-dimensional
scientific diagram. Even diagrams which scored full marks often included carelessly implemented
joints and delivery tubes; the most common error among these was the omission of water from the
measuring cylinder. A substantial minority of candidates drew an apparatus which used a gas
syringe to collect the carbon dioxide despite the description in the procedure and the clear
requirement, stated in the question, for gas collection over water. Other candidates drew a variety of
unsuitable apparatus set-ups including those used in organic preparations.
2(b) Most candidates realised that ethanoic acid was weaker than hydrochloric acid but connecting
this to the need for the reaction to proceed quite slowly proved more of a challenge. Candidates

often suggested that different gases might be formed or that the production of hydrogen chloride
would interfere with the measurement of the gas volume.
2(c) Candidates generally relied on statements about increasing the accuracy of the mass
measurement and missed the key point about accounting for any calcium carbonate left in the
weighing bottle.
2(d) Most candidates were able to draw the graph correctly and determine the volume of gas
required. There were two common errors in constructing the graph: reversing the axes so that mass
of calcium carbonate was on the y-axis; using non uniform scales, particularly giving 0.10 g one
large square from the origin and then giving two large squares for subsequent increments of 0.10 g.
Candidates generally appreciated that the line of best fit would omit the anomalous point but some
attempted a line that diverted to include this or just drew a straight line that averaged the full set.
The first two marking points in the calculation proved very accessible although some candidates
used the molar mass of carbon dioxide rather than that of calcium carbonate. The third marking
point proved far more difficult with some candidates unable to see how to use the moles of calcium
carbonate calculated and even when this was understood the final answer might be spoiled by
incorrect units, often mol dm−3. Some candidates attempted a calculation using the gas molar
volume that they were supposed to be determining and unsurprisingly made little progress while
others focused on the amount of acid used in the experiment.
2(e) Candidates tended to rely on generalisations such as loss of gas or to ignore the injunction
given in the question to assume appropriate conditions and correct experimental procedure.
Candidates who were able to think their way through the procedure realised that the bung could not
be replaced instantaneously while many were aware that carbon dioxide is soluble in water. A
significant number of responses were based on the idea that the result could be affected by carbon
dioxide remaining in the boiling tube.
Question 3
3(a)(i) While the flammable symbol was well known, some candidates used synonyms such as
combustible, which were not accepted for so common a symbol. The symbol for ‘harmful to the
environment’ was unfamiliar to most candidates, although roughly equivalent statements were
allowed. Many chose descriptions, such as toxic and corrosive, that were clearly incorrect.
3(a)(ii) Sensible methods for reducing the risk of using flammable reagents were often suggested,
although some still relied on unsuitable general precautions such as carrying out the experiment in a
fume cupboard. The risk reduction mark for the use of cyclohexene depended on their having
correctly identified the symbol or given a near miss in (a)(i). The idea of controlling the disposal of
the waste was appreciated by many of these candidates.
3(b) The many correct answers were evenly split between controlling the size of the bubbles and
distributing the heat evenly. Some candidates suggested that anti-bumping granules prevented the
formation of bubbles altogether or acted catalytically; others simply reiterated the statement that
they made the liquids boil more smoothly.

3(c) Candidates frequently appreciated that fractional distillation would give better separation or a
purer product than simple distillation but the idea of increasing the reaction time proved elusive.
Candidates rarely used the data provided to deduce that the difficult separation would be of water

and cyclohexene. Some candidates seemed unfamiliar with laboratory fractional distillation and
wrote about the production of different fractions as in the use of fractional distillation in the
treatment of crude oil.
3(d) A number of candidates seemed unfamiliar with the appearance of a separation funnel and
drew a simple filter funnel, often complete with filter paper. Even when the general features of a
separation funnel were known, the diagrams were often poorly executed, omitting the tap or, more
frequently, the capacity of the funnel to be sealed with a bung or a stopper. The positions of the
layers were usually correct although cyclohexanol was sometimes included.
3(e) The role of calcium chloride as a drying agent was widely known but the observation
associated with its use was not. Most of the incorrect responses seemed to be pure guesswork but
some referred to the colour change when anhydrous copper(II) sulfate or cobalt(II) chloride are
hydrated. Some candidates referred incorrectly to calcium chloride acting as a dehydrating agent.
3(f) Few candidates were able to select an appropriate temperature range for distillation, with
almost all the possible combinations of numbers between 25 and 200ºC being offered. Even the
idea of a range centred on 83ºC was quite rare and a significant number of candidates gave a single
temperature. The most common incorrect response was 83─162ºC, the boiling temperatures of
cyclohexene and cyclohexanol.
3(h) The test for the carbon-carbon double bond with bromine water was known by most
candidates, although some gave the starting colour of the reagent as red or red-brown. The
observations for the addition of phosphorus(V) chloride to cyclohexene and cyclohexanol were
much less familiar.
Question 4
4(a) The candidates who scored full marks on this were a minority. Candidates who scored one
mark were most likely to get one colour correct while some reversed the correct colours. Some
candidates gave the colour change for phenolphthalein.
4(b Most candidates read the burette correctly, the most incorrect value being 24.60 cm3.
4(c) Fully correct responses to this question were relatively rare. Some candidates appeared to have
ignored the first sentence and just gave a detailed description of a titration procedure which did not
address the specific point of the question. Otherwise, the common errors were the omission of the
appropriate use of the rough titration and failure to mention the need to mix the reagents during the
addition of the acid. The need for drop-by-drop addition of acid was the mark most likely to be
scored.
4(d) Most candidates were able to tackle this calculation confidently. The most likely reasons for
losing a mark were incorrect use of the volumes of the reagents and omitting or inverting the
reacting ratio.

Paper Summary
Based on their performance on this paper, candidates are offered the following advice:
•

read all the question carefully and use the information provided to help you to frame your
answer

•

state the purpose of each step in calculations, showing your working

•

do not round intermediate values of calculations

•

give the final answer of a calculation to an appropriate number of significant figures or
decimal places, with units if needed

•

learn the conventions for drawing diagrams of scientific apparatus and practise drawing the
apparatus used in AS experiments

•

make sure that you are familiar with the core practicals given in the Advanced level
Specification

•

learn the hazard symbols and their meanings for the substances used in the Advanced level
Specification

•

if your answer extends beyond the allotted space, indicate clearly where you have continued
your answer.

Pearson Education Limited. Registered company number 872828
with its registered office at 80 Strand, London, WC2R 0RL, United Kingdom

Advertisement