Physics · Specimen · Question paper · Paper 3 Section B Option B Medical physics
AQA A Level Physics question paper for Paper 3 Section B Option B Medical physics, Specimen — 7408, file AQA-7408-Paper-3-Section-B-Option-B-Medical-physics-QP-SQP1.pdf.
Text of this paper
SPECIMEN MATERIAL
A-level
PHYSICS
(7408/3BB)
Paper 3 – Section B (Medical Physics)
Specimen 2014
Morning
Time allowed: 2 hours
Materials
For this paper you must have:
• a pencil
• a ruler
• a calculator
• a data and formulae booklet
• a question paper / answer book for Section A.
Instructions
•
•
•
Answer all questions.
Show all your working.
The total time for both sections of this paper is 2 hours.
Information
•
The maximum mark for this section is 35.
Please write clearly, in block capitals, to allow character computer recognition.
Centre number
Surname
Forename(s)
Candidate signature
Candidate number
2
Section B
Answer all questions in this section.
0 1 . 1
State what is meant by the principal focus and the power of a converging lens.
[2 marks]
0 1 . 2
Complete the ray diagram below to show the formation of an image of a real object O
by a diverging lens. Label the image clearly.
[2 marks]
0 1 . 3 State the defect of vision that would be corrected using a diverging lens.
[1 mark]
3
0 1 . 4
A diverging lens of focal length −0.33 m is used to view a real object placed 0.25 m
from the lens.
Calculate the distance from the lens to the image.
[2 marks]
distance from lens to image = m
0 1 . 5
Two point sources of light are viewed by a normal eye and their images are formed at
the fovea.
State, in terms of the active receptors, the conditions necessary for two separate
images to be seen.
[2 marks]
Turn over
4
0 2 . 1
Sound waves are incident on a human ear.
Describe how the frequency and amplitude of the vibrations change as the wave is
transmitted through the ear to the fluid in the inner ear.
[2 marks]
0 2 . 2
Explain how the components of the ear act to amplify the pressure changes due to the
sound wave.
[3 marks]
0 2 . 3
A sound intensity meter, set to the dB scale, is placed near to a source of sound. The
intensity level reading on the sound meter is 82 dB.
−2
Calculate in, W m , the intensity of the sound at the meter.
[3 marks]
−2
intensity = W m
.
5
0 2 . 4
The sound intensity meter is 2.0 m from the source which is emitting sound equally in
all directions.
Calculate the power emitted by the source.
[2 marks]
power = W
Turn over for the next question
Turn over
6
0 3
Positron Emission Tomography (PET) and ultrasound scans are both used in medical
diagnosis. Compare the quality of the information obtained from these scans in terms
of:
•
•
patient safety and convenience
information available to the doctor from the images.
.
[6 marks]
7
0 4 . 1
Explain why the effective half-life of a radionuclide in a biological system is always less
than the physical half-life.
[2 marks]
0 4 . 2
The physical half-life of a radionuclide is 20 days. The nuclide was administered to a
−1
patient. Initially the corrected count rate at the patient’s body was 2700 counts s .
Five days later, the corrected count rate at the same place on the patient was
−1
1200 counts s .
Calculate the biological half-life of the nuclide.
[4 marks]
biological half-life = days
Turn over
8
0 4 . 3
Table 1 gives the properties of two radionuclides.
Table 1
emitted radiation
half-life / hours
energy of gamma ray / keV
Technetium 99 m
gamma
6.0
140
Iodine 131
beta− and gamma
190
610
By considering information in Table 1 suggest which of these nuclides is more
suitable for use as a tracer in medical diagnosis.
[4 marks]
END OF QUESTIONS
Copyright © 2014 AQA and its licensors. All rights reserved.
.