Physics · June 2019 · Question paper · Paper 3 Section B Option B Medical physics

AQA A Level Physics question paper for Paper 3 Section B Option B Medical physics, June 2019 — 7408, file AQA-7408-Paper-3-Section-B-Option-B-Medical-physics-QP-JUN19.pdf.

Advertisement
Loading the paper…
Text of this paper

Please write clearly in block capitals.
Centre number

Candidate number

Surname
Forename(s)
Candidate signature

A-level
PHYSICS
Paper 3
Section B

Medical physics

Monday 3 June 2019

Afternoon

Materials

For this paper you must have:
• a pencil and a ruler
• a scientific calculator
• a Data and Formulae Booklet.

Time allowed: The total time for
both sections of this paper is
2 hours. You are advised to
spend approximately
50 minutes on this section.

Instructions

Use black ink or black ball-point pen.
Fill in the boxes at the top of this page.
Answer all questions.
You must answer the questions in the spaces provided. Do not write
outside the box around each page or on blank pages.
• If you need extra space for your answer(s), use the lined pages at the end of
this book. Write the question number against your answer(s).
• Do all rough work in this book. Cross through any work you do not want
to be marked.
• Show all your working.

•
•
•
•

For Examiner’s Use
Question

Mark

1
2
3
4

TOTAL

Information
•
•
•
•

The marks for questions are shown in brackets.
The maximum mark for this paper is 35.
You are expected to use a scientific calculator where appropriate.
A Data and Formulae Booklet is provided as a loose insert.

*JUN1974083bB01*
IB/M/Jun19/E6

7408/3BB

2
Do not write
outside the
box

Section B
Answer all questions in this section.
0 1

Car drivers must be able to
• read a speedometer from a distance of 50 cm
• read a number plate from a distance of 20.5 m.
A driver has an unaided far point of 55 cm and an unaided near point of 25 cm.

0 1 . 1

Identify the driver’s eye defect.
Tick () one box.

[1 mark]

Astigmatism
Hypermetropia
Myopia

*02*
IB/M/Jun19/7408/3BB

3
0 1 . 2

Figure 1 shows the position of a number plate at a distance of 20.5 m in front of the
driver’s unaided eye.
Figure 2 shows the same situation and the position of a corrective lens.
Complete both ray diagrams to show how and where the image of the number plate is
formed in each case.
Add a suitable lens to Figure 2.
[4 marks]
Figure 1

Figure 2

Question 1 continues on the next page

Turn over ►

*03*
IB/M/Jun19/7408/3BB

Do not write
outside the
box

4
0 1 . 3

An optician considers the use of three different lenses, A, B and C, for use by the
driver when driving.

Do not write
outside the
box

Power of A = ─2.18D
Power of B = ─1.77D
Power of C = +1.95D
Deduce which lens is suitable.
Support your answer with calculations.

[5 marks]

10

*04*
IB/M/Jun19/7408/3BB

5
Do not write
outside the
box

Turn over for the next question

DO NOT WRITE ON THIS PAGE
ANSWER IN THE SPACES PROVIDED

Turn over ►

*05*
IB/M/Jun19/7408/3BB

6
0 2

Three customers, P, Q and R, are sitting in a café listening to music from a
loudspeaker.
Customer P is 11 m from the loudspeaker. At the position of customer P, the sound
–8
–2
intensity is 3.4 × 10 W m .

0 2 . 1

Customer P moves to a distance of 7.0 m from the loudspeaker.
Calculate the sound intensity at the new position of customer P.
Assume that the loudspeaker is a point source.

sound intensity =
0 2 . 2

[2 marks]

W m–2

The sound intensity level is 65 dB at the position of customer Q and 42 dB at the
position of customer R.
Calculate the ratio

sound intensity at the position of Q
.
sound intensity at the position of R

[2 marks]

ratio =

*06*
IB/M/Jun19/7408/3BB

Do not write
outside the
box

7
0 2 . 3

Do not write
outside the
box

Customer Q perceives the loudness of the sound differently to customer R.
Discuss whether the use of intensity level or intensity is more appropriate to compare
the perceived loudness.
[2 marks]

0 2 . 4

Customers P, Q and R move to the same distance from the loudspeaker.
Customer P is 80 years old and has hearing loss due to her age.
Customer Q is 35 years old and has hearing loss due to working in an extremely noisy
environment.
Customer R is 35 years old and has no hearing loss.
The hearing defects of P and Q affect their perception of the music being played.
Describe how their perceptions are different from that of R.

[3 marks]

9

Turn over ►

*07*
IB/M/Jun19/7408/3BB

8
0 3

Figure 3 shows the X-ray spectrum produced in a medical X-ray machine at a
particular anode potential difference (pd).
Figure 3

0 3 . 1

In an X-ray tube, electrons collide with a tungsten target.
Explain how the continuous spectrum and the characteristic spectra are produced by
these electron collisions.
[4 marks]
Continuous spectrum

Characteristic spectra

*08*
IB/M/Jun19/7408/3BB

Do not write
outside the
box

9
0 3 . 2

The dashed line on Figure 4 shows the X-ray spectrum for the initial anode pd.

Do not write
outside the
box

Sketch on Figure 4 the X-ray spectrum produced when the anode pd is increased.
[2 marks]
Figure 4

0 3 . 3

In the medical X-ray machine, the X-rays produced with the initial anode pd are now
passed through an aluminium filter.
The dashed line on Figure 5 shows the X-ray spectrum for the initial anode pd.
Sketch on Figure 5 the X-ray spectrum of the X-rays that emerge from the filter.
[1 mark]
Figure 5

7

Turn over ►

*09*
IB/M/Jun19/7408/3BB

10
Do not write
outside the
box

0 4

Ultrasound is commonly used in medical procedures.

0 4 . 1

An ultrasound A-scan is used to find the length l of an eye as shown in Figure 6.
Figure 7 shows the simplified A-scan for the eye. A short pulse of ultrasound is
transmitted at time t = 0
The average speed of ultrasound in the eye = 1560 m s−1 .
Figure 6

Figure 7

Calculate l.

[3 marks]

l=

m

*10*
IB/M/Jun19/7408/3BB

11
0 4 . 2

Amniocentesis is a procedure where a tube is inserted into a uterus to remove some
cells and fluid from around a foetus. For the procedure to be carried out safely the
positions of the needle, foetus and placenta must be determined accurately.
Discuss whether an A-scan or a B-scan should be used for amniocentesis.
In your answer, you should:
• outline the differences between an A-scan and a B-scan
• describe the advantages and disadvantages of each type of scan
• explain why your chosen scan should be used for this procedure.

[6 marks]

Question 4 continues on the next page
Turn over ►

*11*
IB/M/Jun19/7408/3BB

Do not write
outside the
box

12
Do not write
outside the
box

9

END OF QUESTIONS

*12*
IB/M/Jun19/7408/3BB

13
Do not write
outside the
box

There are no questions printed on this page

DO NOT WRITE ON THIS PAGE
ANSWER IN THE SPACES PROVIDED

*13*
IB/M/Jun19/7408/3BB

14

Question
number

Do not write
outside the
box

Additional page, if required.
Write the question numbers in the left-hand margin.

*14*
IB/M/Jun19/7408/3BB

15

Question
number

Do not write
outside the
box

Additional page, if required.
Write the question numbers in the left-hand margin.

*15*
IB/M/Jun19/7408/3BB

16
Do not write
outside the
box

Additional page, if required.
Write the question numbers in the left-hand margin.

Question
number

Copyright information
For confidentiality purposes, acknowledgements of third-party copyright material are published in a separate booklet rather than
including them on the examination paper or support materials. This booklet is published after each examination series and is
available for free download from www.aqa.org.uk after the live examination series.
Permission to reproduce all copyright material has been applied for. In some cases, efforts to contact copyright-holders may have
been unsuccessful and AQA will be happy to rectify any omissions of acknowledgements. If you have any queries please contact the
Copyright Team, AQA, Stag Hill House, Guildford, GU2 7XJ.
Copyright © 2019 AQA and its licensors. All rights reserved.

*16*

*196A7408/3BB*
IB/M/Jun19/7408/3BB

Advertisement