Physics (9702) · May/June 2026 · Mark scheme · Paper 35
Cambridge International AS & A Level Physics mark scheme for Paper 35, May/June 2026 — 9702/35/M/J/26, file 9702 Physics June 2026 Mark Scheme 35.pdf.
Text of this paper
Cambridge International AS & A Level
PHYSICS
9702/35
Paper 3 Advanced Practical Skills 1
May/June 2026
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme contains the instructions and marking guidance that our examiners used to mark
candidate responses for this component.
Before they start marking, examiners complete a standardisation process. They review a range of candidate
responses and discuss the mark scheme in detail to agree which answers can and cannot be accepted.
Examiners award marks where it is clear that candidate responses have met the requirements of the mark
scheme. These requirements may vary between different components or different versions of the same
component, depending on the exact requirements of the question and the candidate responses seen during
the standardisation process.
Sometimes, our mark schemes may allow marks to be awarded to responses which contain elements that
are factually incorrect or for content not covered by the syllabus. We do this in response to the demands of a
specific question to support candidates and make sure that our assessments are fair. However, these
allowances should not be used as a guide for teaching and learning.
We cannot discuss the mark scheme with schools, and we recommend that schools read the mark scheme
together with the assessment material and the Principal Examiner Report for Teachers.
This document consists of 17 printed pages.
© Cambridge University Press & Assessment 2026
[Turn over
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
May/June 2026
General marking principles
All examiners must apply these marking principles when marking candidate responses.
1
Examiners must award marks for each response in line with:
•
•
•
the specific content defined in the mark scheme
the specific skills defined in the mark scheme or in the level descriptions
the standard of response required as exemplified by the standardisation scripts.
2
Examiners must award whole marks (not half marks, or other fractions).
3
Examiners must award marks positively. This means that:
•
•
•
marks are not deducted for errors or omissions
marks are awarded for correct/valid answers as defined in the mark scheme and also for other valid answers which go beyond the
scope of the syllabus and mark scheme referring to your team leader as appropriate
the quality of spelling, punctuation and grammar are judged only when the mark scheme indicates that these features are specifically
assessed in the question. However, the meaning of all responses must be unambiguous.
4
Examiners must consistently apply the requirements of the mark scheme and any rules for what to do when candidates have not followed
instructions correctly.
5
Examiners must use the full range of marks defined in the mark scheme, unless limited by the quality of the candidate responses seen.
6
Examiners must award marks according to the mark scheme and must not award marks with grade thresholds or grade descriptions in
mind.
© Cambridge University Press & Assessment 2026
Page 2 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
May/June 2026
Science-Specific Marking Principles
1
Examiners should consider the context and scientific use of any keywords when awarding marks. Although keywords may be present, marks
should not be awarded if the keywords are used incorrectly.
2
The examiner should not choose between contradictory statements given in the same question part, and credit should not be awarded for
any correct statement that is contradicted within the same question part. Wrong science that is irrelevant to the question should be ignored.
3
Although spellings do not have to be correct, spellings of syllabus terms must allow for clear and unambiguous separation from other
syllabus terms with which they may be confused (e.g. ethane / ethene, glucagon / glycogen, refraction / reflection).
4
The error carried forward (ecf) principle should be applied, where appropriate. If an incorrect answer is subsequently used in a scientifically
correct way, the candidate should be awarded these subsequent marking points. Further guidance will be included in the mark scheme
where necessary and any exceptions to this general principle will be noted.
5
‘List rule’guidance
For questions that require n responses (e.g. State two reasons …):
•
•
•
•
•
The response should be read as continuous prose, even when numbered answer spaces are provided.
Any response marked ignore in the mark scheme should not count towards n.
Incorrect responses should not be awarded credit but will still count towards n.
Read the entire response to check for any responses that contradict those that would otherwise be credited. Credit should not be
awarded for any responses that are contradicted within the rest of the response. Where two responses contradict one another, this
should be treated as a single incorrect response.
Non-contradictory responses after the first n responses may be ignored even if they include incorrect science.
© Cambridge University Press & Assessment 2026
Page 3 of 17
9702/35
6
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
May/June 2026
Calculation specific guidance
Correct answers to calculations should be given full credit even if there is no working or incorrect working, unless the question states ‘show
your working’.
For questions in which the number of significant figures required is not stated, credit should be awarded for correct answers when rounded
by the examiner to the number of significant figures given in the mark scheme. This may not apply to measured values.
For answers given in standard form (e.g. a 10n) in which the convention of restricting the value of the coefficient (a) to a value between 1
and 10 is not followed, credit may still be awarded if the answer can be converted to the answer given in the mark scheme.
Unless a separate mark is given for a unit, a missing or incorrect unit will normally mean that the final calculation mark is not awarded.
Exceptions to this general principle will be noted in the mark scheme.
7
Guidance for chemical equations
Multiples / fractions of coefficients used in chemical equations are acceptable unless stated otherwise in the mark scheme.
State symbols given in an equation should be ignored unless asked for in the question or stated otherwise in the mark scheme.
© Cambridge University Press & Assessment 2026
Page 4 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
May/June 2026
Annotations guidance for centres
Examiners use a system of annotations as a shorthand for communicating their marking decisions to one another. Examiners are trained during the
standardisation process on how and when to use annotations. The purpose of annotations is to inform the standardisation and monitoring
processes and guide the supervising examiners when they are checking the work of examiners within their team. The meaning of annotations and
how they are used is specific to each component and is understood by all examiners who mark the component.
We publish annotations in our mark schemes to help centres understand the annotations they may see on copies of scripts. Note that there may
not be a direct correlation between the number of annotations on a script and the mark awarded. Similarly, the use of an annotation may not be an
indication of the quality of the response.
The annotations listed below were available to examiners marking this component in this series.
Annotations
Annotation
Meaning
arithmetic error
AWK
awkward scale used on graph
benefit of the doubt given
contradiction in response, mark not awarded
correct point or mark awarded
error carried forward applied
FO
false origin used on graph
incorrect point or mark not awarded
information missing or insufficient for credit
power of ten error
© Cambridge University Press & Assessment 2026
Page 5 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Annotation
Meaning
RO
read-off from graph
SH
supervisor’s help given
SR
supervisor’s report taken into account
SV
supervisor’s value/sample results taken into account
May/June 2026
transcription error
value in range
OOR
value out of range
Abbreviations
/
Alternative and acceptable answers for the same marking point.
()
Bracketed content indicates words which do not need to be explicitly seen to gain credit but which indicate the context for an answer.
The context does not need to be seen but if a context is given that is incorrect then the mark should not be awarded.
SF
Significant figures
© Cambridge University Press & Assessment 2026
Page 6 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
Answer
Marks
May/June 2026
Guidance
1(a)
Final value of d in the range 10.0–35.0 cm with unit.
1 Ignore precision.
1(b)
Without help from Supervisor: six sets of data (different values of M) scores
3 marks, five sets scores 2 marks, four sets scores 1 mark, three or fewer
scores 0 marks.
3 Record the total number of sets of readings
in a ring to left of table.
Allow more than six sets.
If help provided: six sets of readings scores
2 marks, five sets of readings scores 1
mark; four or fewer sets of readings scores
0 marks.
Indicate with SR on script front, with details
near table.
Values recorded in a table for M and d.
1
Trend correct (d decreases as M increases).
1 Judge trend from table not from graph.
Judge trend on mean d, if available. If d not
available judge trend on 1 / d. If M not
available judge trend on n.
Not equal values.
If one or more values in the table is ‘out of
trend’ then this mark not awarded BUT this
may not affect quality mark on the graph
yet.
Range of M: Mmin ⩽ 50 g and Mmax ⩾ 200 g.
1 Ring minimum and maximum values in
table.
Column headings: Each column heading must contain a quantity and a unit
where appropriate. No unit for n.
1 Ignore units in the body of the table. Ignore
POT errors.
Accept separating mark as a solidus,
brackets around units or ‘in’, but not a
comma.
Allow ‘n / no units’ but do not allow ‘n / units’.
The presentation of quantity and unit must conform to accepted scientific
convention, for example 1 / d (m–1).
© Cambridge University Press & Assessment 2026
Page 7 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
1(b)
1(c)(i)
Answer
Marks
May/June 2026
Guidance
Consistency:
All raw values of d to the nearest mm.
1 Do not allow all zero in mm place here.
Significant figures:
All values of 1 / d given to the same number of s.f. as (or one more than) the
number of s.f. in raw d.
1 Check each row
Values of 1 / d calculated correctly.
1 Check value in the last line of the table. If
incorrect from mean d, go back to raw
values and recalculate and if still incorrect,
write in correct value.
Answer should be correct to the number of
sf used by the candidate.
Axes:
Axes must be labelled with the correct quantities.
Scales must be chosen so that the plotted points occupy at
least half the graph grid in both the x and y directions.
1 Accept labels on axes ONLY as 1 / d and n.
Actual numbers need not correspond to
label.
Ignore units.
Do not allow reversed scales.
Minimum 6 large squares on long axis and 4
large squares on short axis.
Ignore point(s) plotted off the grid and
assess on remaining points.
Allow 8:10.
Do not allow awkward markings (e.g. 2.57,
5.57, 4.57 an awkward offset of a sensible
linear scale).
Indicate x-axis false origin with FO.
Scale markings are no more than 2 cm (one large square) apart.
Sensible scales must be used, no awkward scales (e.g. 3:10 or fractions).
© Cambridge University Press & Assessment 2026
Page 8 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
1(c)(i)
Answer
Marks
Plotting of points:
All observations in the table must be plotted on the grid.
Diameter of plotted points must be ⩽ half a small square.
Points must be plotted to an accuracy of half a small
square in both x and y directions.
May/June 2026
Guidance
1 Ignoring any point off the grid, write a ringed
total of points.
Allow correct plotting on a wrong graph.
Indicate reason if mark not awarded. Do not
award if:
• any table value is not plotted;
• numbers do not correspond to axes
label;
• any point has diameter larger than half
a small square (blob);
• a point is (or should be) off the grid
(check point on edge);
• the point furthest from the line is
plotted more than half a small square
out.
Ring and check point furthest from the line.
Tick if correct, re-plot if incorrect. If a point
on the edge is checked and found correct
still check point furthest from the line.
Quality: Trend of points must be positive
All points in the table (at least 5) must be plotted on the grid for this mark to
be awarded.
It must be possible to draw a straight line that is within 1 on the n axis of all
plotted points.
© Cambridge University Press & Assessment 2026
Page 9 of 17
1 Ignore line drawn by the candidate.
If examiner has replotted a point judge
quality on position of replot.
Indicate the tolerance on the graph.
Indicate reason if mark not awarded.
Do not award if:
• wrong trend on the graph (i.e. negative
gradient);
• a point is (or should be) off the grid
(check pt on edge);
• non-linear scale in region of the points;
• wrong quantity plotted or calculated;
• 4 or fewer plotted points.
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
1(c)(ii)
Answer
Marks
Line of best fit:
‘Best fit’ is judged by the balance of all points on the grid (at least 5 points)
about the candidate’s line.
There must be an even distribution of points either side of the line along the
full length.
Lines must not be kinked or thicker than half a square.
Some candidates may choose to identify an anomalous point. If they identify
one point as anomalous (e.g. by circling or labelling) then this point is to be
disregarded when judging the line of best fit. There must be at least 5 points
left after the anomalous point is disregarded.
© Cambridge University Press & Assessment 2026
Page 10 of 17
May/June 2026
Guidance
1 Allow a straight line through a curved trend.
Indicate reason if not awarded. Do not
award if:
• rotation or translation achieves a better
fit;
• line is kinked;
• a curve has been drawn;
• line is thicker than 1 mm or ‘hairy’;
• points are too scattered to judge;
• there are 4 or fewer points.
• Line does not span all plotted points
considered in assessing the line (line
must span in either the x or y direction).
Assess line on all points if more than one
point is identified as anomalous or only 5
points are plotted on the grid.
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
1(c)(iii)
Answer
Marks
Gradient: gradient sign on answer line consistent with graph drawn.
The hypotenuse of the triangle used should be greater than half the length of
the drawn line.
Both read-offs must be accurate to half a small square in both the x and y
directions.
Method of calculation must be correct, not x / y.
May/June 2026
Guidance
1 Allow hypotenuse to be exactly half the
length of the drawn line.
Correct substitution must be shown. Do not
check beyond the substitution.
If a read-off is incorrect, write in correct
value(s). Ignore POT error if it is the same
for all values.
Allow use of points from the table ONLY if
they are less than or equal to half a small
square from the line. Check points.
Ignore units.
Other valid methods:
1 Using simultaneous equations;
2 Counting squares scale factor (must
see a triangle);
3 Using only y and x (without readoffs) – check these values to one small
square using their triangle (triangle
must be shown).
© Cambridge University Press & Assessment 2026
Page 11 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
1(c)(iii)
Answer
Marks
y-intercept:
Intercept read directly from the graph, with read-off at n = 0, accurate to half
a small square in 1 / d direction.
or
Correct read-off from a point on the line is substituted into y = mx + c or an
equivalent expression.
P = candidate’s gradient value and Q = candidate’s intercept value.
Values must not be written as fractions or given to only one significant figure.
Guidance
1 Check for x-axis false origin (FO) i.e. n 0.
Allow read off for curve.
Allow ecf of gradient value, m.
Check correct substitution in y = mx + c. Do
not check beyond the substitution.
If read-off used is incorrect and gradient
mark not awarded because of this incorrect
read-off, then check 2nd read-off in the
gradient substitution. If this 2nd read-off is
also incorrect, do not allow the intercept
mark. If correct, allow ecf and award the
mark.
Ignore POT.
Read-off accurate to half a small square in both x and y directions.
1(d)
May/June 2026
1 Special case when Q is read off the axis:
allow 1 sf for Q if it is close to the origin and
can only be read to 1 sf.
Allow POT adjustment if consistent with
unit.
Ignore any working.
If axes are inverted, this mark cannot be
awarded unless the candidate makes a
correction at this point (true gradient = 1 /
candidate’s gradient and true intercept = –
candidate’s intercept / candidate’s gradient).
Unit for P consistent with readings: cm–1 or m–1.
Unit for Q consistent with readings: cm–1 or m–1.
© Cambridge University Press & Assessment 2026
1
Page 12 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
1(e)
Answer
Marks
10Q
̶ 10
P
using candidate’s values of P and Q and with consistent unit.
Calculation of S =
May/June 2026
Guidance
1 Check unit first.
Check calculation when rounded to 2 sf is
the same as the examiner’s value when
rounded to 2 sf.
Allow S to 1 sf only if credit not awarded in
1(d) because of a 1 sf value.
© Cambridge University Press & Assessment 2026
Page 13 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
2(a)(i)
Answer
Marks
Absolute uncertainty in L in range 3–8 mm.
Correct method of calculation to find percentage uncertainty e.g. absolute
uncertainty / L 100.
May/June 2026
Guidance
1 With 100 seen or implied
If repeated readings have been taken, then the uncertainty can be half the
range if the working is clearly shown, but NOT zero if values are equal
2(a)(ii)
45.0 cm < both DB and DC measurements < 50.0 cm with unit and to the
nearest mm.
1
2(b)(i)
Raw value(s) and final value of R to at least the nearest 0.1 with unit.
and
final value ⩾ 1.0 .
1 Allow answer line value to the nearest
0.01 only if repeats are seen to the
nearest 0.1 .
2(b)(ii)
Correct calculation of (DB – x) and (DC + x).
1 Check used consistent units in calculation.
2(b)(iii)
RX < R.
1 Ignore precision. If unit missing, assume
same unit as R.
2(b)(iv)
Correct calculation of RX / R.
1 Value of RX / R correct to the same number
of sf as the candidate’s answer. Ignore unit
if given.
2(b)(v)
Justification for significant figures in RX / R linked to significant figures
in RX and R.
1 Ignore the actual sf used in calculation.
Do not allow reference to L, DB or DC.
Do not allow ‘raw readings’.
Any additional numerical justification must
be valid.
Second values of (DB – x) and (DC + x).
1 Different values of (DB – x) and (DC + x).
Second value of RX.
1
Second value of RX < first value of RX.
1
2(c)
© Cambridge University Press & Assessment 2026
Page 14 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
2(d)
Answer
Marks
Two values of k calculated correctly.
The final k values must not be written as fractions or given to one significant
figure.
2(e)
Calculation of percentage difference between candidate’s two k values.
Comparison of percentage difference with 15% leading to a consistent
conclusion.
© Cambridge University Press & Assessment 2026
May/June 2026
Page 15 of 17
Guidance
1 Do not allow either k to 1 sf.
Check k value for values from 2(c) on page
9 when rounded to 2 sf is the same as the
examiner’s value when also rounded to 2 sf.
If incorrect, record correct value.
Ignore POTs if same for both k values.
Allow values of k to be written on either line.
If no working shown still award mark if k
value correct.
1 1
% difference calculation. Allow the use
of half the % difference calculation e.g.
(k1 – k2) / (k1 + k2).
2 Comparison to 15(%) or ‘the
(suggested/percentage) uncertainty’.
Do not allow any other uncertainty e.g.
their own or the uncertainty in 2(a)(i).
3 Valid comment linking points 1 and 2.
The candidate’s conclusion must be
consistent with the criterion 15%.
Special Cases:
Allow the statement k1 = k2 only if the values
are the same to 3 s.f. with a valid conclusion
stated. Allow use of 15% criterion with one
or both k values to determine whether there
is an overlap or not with a valid conclusion
stated.
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
2(f)(i)
Answer
Marks
A
Two (sets of) readings are not enough to draw a valid conclusion
or
two k values are not enough to draw a conclusion.
May/June 2026
Guidance
4 Do not allow ‘Two readings not enough for
(accurate) results’.
Allow not enough k values to draw a
conclusion.
Allow ‘(one or) two readings are not enough
to draw a conclusion’.
Allow ‘too few readings for a conclusion’.
Allow ‘…. to conclude (the experiment)’.
Do not allow ‘… to conclude the results’.
Allow reference to ‘relationship’ to mean
‘conclusion’.
B
Difficulty with determining L with a reason related to start of the wire e.g.
width of solder blob, determining where the wire twist finishes, determining
the length of the curved section of the wire.
C
Difficult with determining L, DB or DC with reason e.g. width of crocodile
clips / kinked wires / resistance wire is loose on metre rule.
Ignore ‘loose or poor connections’ on its
own.
Accept ‘lengths’ instead of L, DB or DC.
Do not allow ‘distances’.
D
Difficulty determining R or RX with reason e.g. fluctuating / unstable reading
owing to poor connections between crocodile clip(s) and wire.
Accept ‘resistance’ or ‘ohmmeter reading’ to
mean R or Rx. Ignore ‘loose or poor
connections’ on its own.
E
Precision of ohmmeter is only 0.1
or
both values of RX are similar.
© Cambridge University Press & Assessment 2026
Page 16 of 17
9702/35
Cambridge International AS & A Level – Mark Scheme
PUBLISHED
Question
2(f)(ii)
Answer
Marks
A
Take more readings (for different values of x) and plot a graph
or
take more readings and compare k values.
May/June 2026
Guidance
4 Do not allow ‘Repeat readings’ on its own.
Do not allow ‘take more readings and
(calculate) average k.
Allow ‘repeat readings and plot a graph’.
Do not allow ‘repeat readings and draw a
line’ without reference to a graph.
B
Method of improving the measurement of L e.g. use a single wire (with no
join), use a connection box, measure and mark L before putting onto the
rule.
Do not allow ‘put end on ruler’.
C
Method of improved connection at B or C e.g. use jockey
or
method of ensuring the wire remains straight e.g. wrap wire around screws
at both ends of rule.
Accept a thinner crocodile clip.
Accept clamp wire to both ends of ruler.
Do not accept soldering the crocodile clip to
the wire.
Do not allow (more) tape.
D
Improved method to reduce stability of resistance reading e.g. use
sandpaper on crocodile clips or wire or use tighter crocodile clips.
Allow ‘new crocodile clips with less rust on’.
Do not allow ‘clean the crocodile clips’.
E
Use ohmmeter with precision 0.01 or greater or ammeter and voltmeter
with higher precision than ohmmeter.
or
use larger values of x.
Allow more precise ohmmeter.
© Cambridge University Press & Assessment 2026
Page 17 of 17