Chemistry (9701) · May/June 2026 · Confidential instructions · Paper 37

Cambridge International AS & A Level Chemistry confidential instructions for Paper 37, May/June 2026 — 9701/37/M/J/26, file 9701 Chemistry June 2026 Confidential Instructions 37.pdf.

Advertisement
Loading the paper…
Text of this paper

Cambridge International AS & A Level
CHEMISTRY

9701/37

Paper 3 Advanced Practical Skills 1

May/June 2026

CONFIDENTIAL INSTRUCTIONS
* 5 9 0 6 0 2 1 9 9 1 *

This document gives details of how to prepare for and administer the practical exam.
The information in this document and the identity of any materials supplied by Cambridge International
are confidential and must NOT reach candidates either directly or indirectly.
The supervisor must complete the report at the end of this document and return it with the scripts.
INSTRUCTIONS
●
If you have any queries regarding these confidential instructions, contact Cambridge International
stating the centre number, the syllabus and component number and the nature of the query.
email [email protected]
phone +44 1223 553554

This document has 8 pages. Any blank pages are indicated.
DC (LO) 368692
© Cambridge University Press & Assessment 2026

[Turn over

2

General information about practical exams
Centres must follow the guidance on science practical exams given in the Cambridge Handbook.

Safety
Supervisors must follow national and local regulations relating to safety and first aid.
Only those procedures described in the question paper should be attempted.
Supervisors must inform candidates that materials and apparatus used in the exam should be treated
with caution. Suitable eye protection should be used where necessary.
The following hazard codes are used in these confidential instructions, where relevant:
C
HH
F
N

corrosive
health hazard
flammable
hazardous to the aquatic environment

MH
T
O

moderate hazard
acutely toxic
oxidising

Hazard data sheets relating to substances used in this exam should be available from your
chemical supplier.

Before the exam
●
●
●

The packets containing the question papers must not be opened before the exam.
It is assumed that standard school laboratory facilities, as indicated in the Guide to Planning
Practical Science, will be available.
Spare materials and apparatus for the tasks set must be available for candidates, if required.

During the exam
●
●
●
●

It must be made clear to candidates at the start of the exam that they may request spare
materials and apparatus for the tasks set.
Where specified, the supervisor must perform the experiments and record the results as
instructed. This must be done out of sight of the candidates, using the same materials and
apparatus as the candidates.
Any assistance provided to candidates must be recorded in the supervisor’s report.
If any materials or apparatus need to be replaced, for example, in the event of breakage or loss,
this must be recorded in the supervisor’s report.

After the exam
●
●

The supervisor must complete a report for each practical session held and each laboratory used.
Each packet of scripts returned to Cambridge International must contain the following items:
–
the scripts of the candidates specified on the bar code label provided
–
the supervisor’s results relevant to these candidates
–
the supervisor’s reports relevant to these candidates
–
seating plans for each practical session, referring to each candidate by candidate number
–
the attendance register.

© Cambridge University Press & Assessment 2026

9701/37/CI/M/J/26

3

Specific information for this practical exam
During the exam, the supervisor (not the invigilator) must do all the experiments and record the
results on a spare copy of the question paper, clearly labelled ‘supervisor’s results’.
If chemicals are prepared in more than one batch, clearly labelled supervisor’s results must be
provided for each batch. The candidates using each batch must be listed on the supervisor’s report.
Apparatus
The apparatus listed must be provided to each candidate.
1 × 25 cm3 pipette
1 × pipette filler
1 × 50 cm3 burette
2 × 150 cm3 or 250 cm3 conical flask
1 × 50 cm3 measuring cylinder
1 × 250 cm3 plastic or glass measuring cylinder
1 × burette stand and clamp
2 × 100 cm3 beaker
1 × 250 cm3 beaker
1 × funnel (for filling burette)
1 × white tile
2 × stand and clamp
1 × tub suitable for acting as trough (minimum capacity 1 dm3)
1 × 150 cm3 or 250 cm3 side-arm conical flask labelled X with bung connected to approximately 50 cm
of plastic/rubber delivery tube OR additional 150 cm3 or 250 cm3 conical flask labelled X with one-hole
bung connected to approximately 50 cm of plastic/rubber delivery tube
1 × glass rod
2 × teat/dropping pipette
1 × spatula
1 × tripod
1 × gauze
1 × Bunsen burner
1 × heat-proof mat
1 × test-tube holder
1 × boiling tube
8 × test-tube*
1 × test-tube rack
balance, single-pan, direct reading, minimum accuracy 0.01 g, weighing to 200 g (1 per 8–12 candidates)
1 × wash bottle containing distilled water
1 × pen for labelling glassware
paper towels
red and blue litmus papers
aluminium foil
wooden splints
the apparatus normally used in the centre for use with limewater in testing for carbon dioxide
*Candidates are expected to rinse and reuse test-tubes where possible.
Additional test-tubes should be available.
If the centre cannot provide sufficient stands and clamps, the candidates should be instructed to
complete Question 3 before Question 2.
© Cambridge University Press & Assessment 2026

9701/37/CI/M/J/26

[Turn over

© Cambridge University Press & Assessment 2026

9701/37/CI/M/J/26

0.20 mol dm–3 potassium bromide

0.050 mol dm–3 chromium(III) sulfate with
0.20 mol dm–3 sodium nitrate

1.0 mol dm–3 sodium hydroxide

0.20 mol dm–3 copper(II) sulfate

5 cm3

15 cm3

15 cm3

5 cm3

FA 6

FA 7

FA 8 [C]

copper
sulfate [C][N]

0.050 mol dm–3 chromium(III) nitrate with
0.20 mol dm–3 sodium sulfate

OR

thymolphthalein indicator

2 cm3

FA 5
[F][MH][HH]

0.100 mol dm–3 hydrochloric acid

0.095 mol dm–3 sodium hydroxide

120 cm3

FA 3

120 cm3

0.25 mol dm–3 sulfuric acid

70 cm3

FA 2

FA 4

magnesium pieces

identity

0.17 g

per
candidate

FA 1 [F]

label

The materials listed in the table must be provided to each candidate.

Materials

Dissolve 31.9 g of CuSO4 [C][MH][N] or 49.9 g of CuSO4•5H2O [C][MH][N]
in each dm3 of solution.

See preparation instructions in the current syllabus.

Dissolve 19.6 g of Cr2(SO4)3 and 17.0 g of NaNO3 [O][MH] in each dm3
of solution.
19.6 g of CrK(SO4)2•6H2O [MH] is a suitable alternative to chromium(III)
sulfate. (This may be listed as chrome alum by chemical suppliers.)
(20.2 g KNO3 [O] is a suitable alternative to NaNO3.)
Alternatively, dissolve 11.9 g of Cr(NO3)3 [O][MH] and 28.4 g of Na2SO4
(or 64.4 g of Na2SO4•10H2O) in each dm3 of solution.

Dissolve 23.8 g of KBr in each dm3 of solution.
(20.6 g of NaBr is a suitable alternative.)

See preparation instructions in the current syllabus.
(Thymol blue indicator [F][MH][HH][N] is also suitable.)

Dilute 50.0 cm3 of 2.0 mol dm–3 HCl to 1 dm3.
For 2.0 mol dm–3 HCl, see preparation instructions in the current syllabus.

Dissolve 3.80 g of NaOH [C] in each dm3 of solution.
Care: the process of solution is exothermic and any concentrated
solution is very corrosive.

Dilute 250 cm3 of 1.0 mol dm–3 H2SO4 [MH] to 1 dm3. Supply in a
stoppered container.
For 1.0 mol dm–3 H2SO4, see preparation instructions in the
current syllabus.

Supply 0.17 ± 0.01 g of Mg pieces [F] in a stoppered container.
Suppliers may describe these as magnesium turnings.
(Mg ribbon [F] cut into small pieces is a suitable alternative.)

notes

4

© Cambridge University Press & Assessment 2026

1.0 mol dm–3 H2SO4
2.0 mol dm–3 NH3
1.0 mol dm–3 NaOH
0.1 mol dm–3 BaCl 2
or
0.1 mol dm–3 Ba(NO3)2
saturated aqueous calcium hydroxide, Ca(OH)2
0.05 mol dm–3 AgNO3
0.01 mol dm–3 KMnO4 in 0.5 mol dm–3 H2SO4

10 cm3

10 cm3

10 cm3

10 cm3

10 cm3

10 cm3

10 cm3

dilute sulfuric acid [MH]

aqueous ammonia [C][MH][N]

aqueous sodium hydroxide [C]

aqueous barium chloride
or
aqueous barium nitrate

limewater [MH]

aqueous silver nitrate

acidified aqueous potassium
manganate(VII) [MH]

9701/37/CI/M/J/26

●

●

Invigilators must be alert to the risk of
contamination and the opportunity for malpractice
when using a communal supply.

If necessary, each of these reagents can be
provided as a communal supply for groups of up
to 6 candidates.

See preparation instructions in the current syllabus.

notes

An excess of at least 10% of each material must be prepared to cover accidental loss.
All solutions must be thoroughly mixed.
If you are unable to source any of these chemicals, you must contact Cambridge International as far as possible in advance of the exam
for advice.
Only provide the chemicals listed on pages 4 and 5 in the Confidential Instructions. Centres should not provide any additional chemicals to
candidates without approval from Cambridge International in advance of the exam.
Materials must be labelled only as specified in the ‘label’ column. The identities of chemicals labelled with letter codes, e.g. FA 1,
may be different from their descriptions in the question paper. Candidates must use the descriptions given in the question
paper. For example, candidates may be supplied with sulfuric acid, labelled as FA 1, but be told in the question paper that FA 1 is
phosphoric acid.

2.0 mol dm–3 HNO3

10 cm3

dilute nitric acid [C]

●
●
●

2.0 mol dm–3 HCl

identity

10 cm3

per
candidate

dilute hydrochloric acid

label

5

[Turn over

6
BLANK PAGE

Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (Cambridge University Press & Assessment) to trace copyright holders, but if any items requiring clearance
have unwittingly been included, the publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in our Copyright
Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download at www.cambridgeinternational.org after the live
examination series.
Cambridge International Education is the name of our awarding body and a part of Cambridge University Press & Assessment, which is a department of the
University of Cambridge.

© Cambridge University Press & Assessment 2026

9701/37/CI/M/J/26

7

Supervisor’s report
Syllabus and component number

/

Centre number
Centre name
Time of the practical session
Laboratory name/number
Give details of any difficulties experienced by the centre or by candidates (include the relevant
candidate names and candidate numbers).
You must include:
●
●
●

any difficulties experienced by the centre in the preparation of materials
any difficulties experienced by candidates, e.g. due to faulty materials or apparatus
any specific assistance given to candidates.

© Cambridge University Press & Assessment 2026

9701/37/CI/M/J/26

[Turn over

8
If chemicals have been prepared in more than one batch, list the candidates using each batch.

Declaration
1 Each packet that I am returning to Cambridge International contains all of the following items:
●
●
●
●
●

the scripts of the candidates specified on the bar code label provided
the supervisor’s results relevant to these candidates
the supervisor’s reports relevant to these candidates
seating plans for each practical session, referring to each candidate by candidate number
the attendance register.

2 Where the practical exam has taken place in more than one practical session, I have clearly
labelled the supervisor’s results, supervisor’s reports and seating plans with the time and
laboratory name/number for each practical session.
3 I have included details of difficulties relating to each practical session experienced by the centre or
by candidates.
4 I have reported any other adverse circumstances affecting candidates, e.g. illness, bereavement
or temporary injury, directly to Cambridge International on a special consideration form.
Signed (supervisor)
Name (in block capitals)
© Cambridge University Press & Assessment 2026

9701/37/CI/M/J/26