Physics (5054) · May/June 2026 · Confidential instructions · Paper 32
Cambridge O Level Physics confidential instructions for Paper 32, May/June 2026 — 5054/32/M/J/26, file 5054 Physics June 2026 Confidential Instructions 32.pdf.
Text of this paper
Cambridge O Level
PHYSICS
5054/32
May/June 2026
Paper 3 Practical Test
CONFIDENTIAL INSTRUCTIONS
* 4 8 2 5 8 6 6 3 6 0 *
This document gives details of how to prepare for and administer the practical exam.
The information in this document and the identity of any materials supplied by Cambridge International
are confidential and must NOT reach candidates either directly or indirectly.
The supervisor must complete the report at the end of this document and return it with the scripts.
INSTRUCTIONS
●
If you have any queries regarding these confidential instructions, contact Cambridge International
stating the centre number, the syllabus and component number and the nature of the query.
email [email protected]
phone +44 1223 553554
This document has 8 pages.
DC (CJ/TC) 360244/5
© Cambridge University Press & Assessment 2026
[Turn over
2
General information about practical exams
Centres must follow the guidance on science practical exams given in the Cambridge Handbook.
Safety
Supervisors must follow national and local regulations relating to safety and first aid.
Only those procedures described in the question paper should be attempted.
Supervisors must inform candidates that materials and apparatus used in the exam should be treated
with caution. Suitable eye protection should be used where necessary.
The following hazard codes are used in these confidential instructions, where relevant:
C
HH
F
N
corrosive
health hazard
flammable
hazardous to the aquatic environment
MH
T
O
moderate hazard
acutely toxic
oxidising
Hazard data sheets relating to substances used in this exam should be available from your
chemical supplier.
Before the exam
●
●
●
The packets containing the question papers must not be opened before the exam.
It is assumed that standard school laboratory facilities, as indicated in the Guide to Planning
Practical Science, will be available.
Spare materials and apparatus for the tasks set must be available for candidates, if required.
During the exam
●
●
●
●
It must be made clear to candidates at the start of the exam that they may request spare
materials and apparatus for the tasks set.
Where specified, the supervisor must perform the experiments and record the results as
instructed. This must be done out of sight of the candidates, using the same materials and
apparatus as the candidates.
Any assistance provided to candidates must be recorded in the supervisor’s report.
If any materials or apparatus need to be replaced, for example, in the event of breakage or loss,
this must be recorded in the supervisor’s report.
After the exam
●
●
The supervisor must complete a report for each practical session held and each laboratory used.
Each packet of scripts returned to Cambridge International must contain the following items:
–
the scripts of the candidates specified on the bar code label provided
–
the supervisor’s results relevant to these candidates
–
the supervisor’s reports relevant to these candidates
–
seating plans for each practical session, referring to each candidate by candidate number
–
the attendance register.
© Cambridge University Press & Assessment 2026
5054/32/CI/M/J/26
3
Specific information for this practical exam
During the exam, the supervisor (not the invigilator) must do the experiments in Questions 1,2 and
3 and record the results on a spare copy of the question paper, clearly labelled ‘supervisor’s results’.
Question 1
Items to be supplied by the centre (per set of apparatus, unless otherwise specified):
●
●
●
●
●
clamp, boss and stand
pendulum bob attached to approximately 90 cm of thread (see Notes 1 and 2)
split cork or similar to hold the thread in the clamp
metre rule with a millimetre scale
stopwatch.
Notes
1
The pendulum must be set up for candidates as shown in Figure 1.1.
The length l of the pendulum must be approximately 50 cm from the bottom of the split cork to the
centre of the pendulum bob.
clamp
l
stand
bob
bench
Figure 1.1
2
Candidates must be able to adjust the length of the pendulum easily up to a length of 70 cm.
Retort stands with a height of 70 cm or less may be used if the retort stand is reversed so that the
pendulum is suspended below the level of the bench.
In this case, the base of the stand should now be secured with a G-clamp or heavy weight, and
the difference between the diagram in Figure 1.1 and the actual arrangement of the apparatus
should be pointed out to the candidates.
Action at changeover
The pendulum must be restored to the state described in Note 1.
Information required by examiners
A sample set of numerical results clearly marked ‘supervisor’s results’, obtained out of sight of
the candidates.
© Cambridge University Press & Assessment 2026
5054/32/CI/M/J/26
[Turn over
4
Question 2
Items to be supplied by the centre (per set of apparatus, unless otherwise specified):
●
●
●
●
●
●
●
2 × 250 cm3 beakers labelled P and Q, each with the 200 cm3 level marked (see Note 1)
stirring thermometer, measuring from –10 °C to 110 °C, graduated in 1 °C intervals
supply of hot water at approximately 80 °C (see Notes 1 and 3)
stopwatch
insulation (see Note 2)
lid (see Note 2)
paper towels to mop up any water spillages.
Notes
1
Each candidate will require 400 cm3 of hot water. The hot water should be supplied and
maintained at a constant temperature of between 80 °C and 90 °C. The supervisor will be
asked by each candidate to fill a beaker with 200 cm3 of hot water at different times during the
experiment. To facilitate the filling of the beaker with water without removing the insulation, the
200 cm3 mark should be visible when viewing the inside of the beaker.
Several electric kettles are suitable to ensure that the water provided is at the
required temperature.
2
The beakers should be supplied as shown in Figure 2.1. Beaker P must have a layer of insulation
made from newspaper, cotton wool, corrugated cardboard or similar, approximately 5 mm thick,
and fixed to the outside of the beaker with rubber bands or tape.
Beaker Q must have a lid made from a piece of card approximately 2 mm thick, in which there is
a hole to insert the thermometer.
lid
layer of insulation
beaker Q
beaker P
Figure 2.1
3
Candidates must be warned of the dangers of burns or scalds when using very hot water.
Action at changeover
Remove the thermometer from the beaker, and empty the water from the beakers.
Check the condition of the insulation and the lid.
Information required by examiners
A sample set of numerical results clearly marked ‘supervisor’s results’, obtained out of sight of
the candidates.
© Cambridge University Press & Assessment 2026
5054/32/CI/M/J/26
5
Question 3
Items to be supplied by the centre (per set of apparatus, unless otherwise specified):
●
●
●
●
●
●
3 dry cells connected in series by means of a suitable holder(s) to form a 4.5 V battery (see
Note 1)
switch
ammeter capable of measuring currents up to 1.0 A with a precision of 0.05 A or better (see
Note 3)
voltmeter capable of measuring a potential difference up to 5 V with a precision of 0.1 V or better
(see Note 3)
resistors of resistances 12 Ω, 15 Ω, 18 Ω, 22 Ω and 33 Ω, with a power rating of 2 W (see Note 4)
8 connecting leads.
Notes
1
The 4.5 V battery should provide a minimum voltage of 3.0 V when connected across the
12 Ω resistor.
2
The supervisor must arrange the circuit shown in Figure 3.1 for the candidates in advance of
the examination.
Terminals P and Q must be labelled and be suitable to connect to the resistors. Dry cells must be
used as a power source.
V
A
P
Q
Figure 3.1
3
An analogue or digital meter is suitable. If a digital multimeter is used, the dial must be set to the
correct range and then taped over. Unused terminals must also be taped over.
4
The supervisor must label each resistor with its value.
The RS Components International component codes of suitable resistors are:
12 Ω:
15 Ω:
18 Ω:
22 Ω:
33 Ω:
683-5650
683-5653
683-5657
683-5666
683-5663.
The resistors must be connected to terminals that will enable them to be connected into the rest
of the circuit.
© Cambridge University Press & Assessment 2026
5054/32/CI/M/J/26
[Turn over
6
Action at changeover
The battery should be tested to ensure that it still provides a minimum voltage of 3 V when connected
across a 12 Ω resistor, and the cells should be replaced if necessary.
The circuit must be restored to its original state as shown in Figure 3.1, with the switch open and the
resistors placed by the side of the circuit.
Information required by examiners
A sample set of numerical results clearly marked ‘supervisor’s results’, obtained out of sight of
the candidates.
Question 4
Planning question – no apparatus is required for this question.
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (Cambridge University Press & Assessment) to trace copyright holders, but if any items requiring clearance
have unwittingly been included, the publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in our Copyright
Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download at www.cambridgeinternational.org after the live
examination series.
Cambridge International Education is the name of our awarding body and a part of Cambridge University Press & Assessment, which is a department of the
University of Cambridge.
© Cambridge University Press & Assessment 2026
5054/32/CI/M/J/26
7
Supervisor’s report
Syllabus and component number
/
Centre number
Centre name
Time of the practical session
Laboratory name/number
Give details of any difficulties experienced by the centre or by candidates (include the relevant
candidate names and candidate numbers).
You must include:
●
●
●
any difficulties experienced by the centre in the preparation of materials
any difficulties experienced by candidates, e.g. due to faulty materials or apparatus
any specific assistance given to candidates.
© Cambridge University Press & Assessment 2026
5054/32/CI/M/J/26
[Turn over
8
Declaration
1 Each packet that I am returning to Cambridge International contains all of the following items:
●
●
●
●
●
the scripts of the candidates specified on the bar code label provided
the supervisor’s results relevant to these candidates
the supervisor’s reports relevant to these candidates
seating plans for each practical session, referring to each candidate by candidate number
the attendance register.
2 Where the practical exam has taken place in more than one practical session, I have clearly
labelled the supervisor’s results, supervisor’s reports and seating plans with the time and
laboratory name/number for each practical session.
3 I have included details of difficulties relating to each practical session experienced by the centre or
by candidates.
4 I have reported any other adverse circumstances affecting candidates, e.g. illness, bereavement
or temporary injury, directly to Cambridge International on a special consideration form.
Signed (supervisor)
Name (in block capitals)
© Cambridge University Press & Assessment 2026
5054/32/CI/M/J/26