Physics (9702) · Oct/Nov 2015 · Mark scheme 35
Cambridge Physics (9702) mark scheme for paper 35, Oct/Nov 2015 — 9702/35/O/N/15, file 9702_w15_ms_35.pdf.
Text of this paper
www.dynamicpapers.com
CAMBRIDGE INTERNATIONAL EXAMINATIONS
Cambridge International Advanced Subsidiary and Advanced Level
MARK SCHEME for the October/November 2015 series
9702 PHYSICS
9702/35
Paper 3 (Advanced Practical Skills 1),
maximum raw mark 40
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of
the examination. It shows the basis on which Examiners were instructed to award marks. It does not
indicate the details of the discussions that took place at an Examiners’ meeting before marking began,
which would have considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner
Report for Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the October/November 2015 series for most
Cambridge IGCSE®, Cambridge International A and AS Level components and some
Cambridge O Level components.
® IGCSE is the registered trademark of Cambridge International Examinations.
www.dynamicpapers.com
Page 2
1
Mark Scheme
Cambridge International AS/A Level – October/November 2015
Syllabus
9702
Paper
35
(b) (i) Value of a with consistent unit and in the range 0 to 50.0 cm.
[1]
(v) Value of V with unit to nearest 0.001 V and in range 0 to 2 V.
[1]
(c) Six sets of readings of a, b and V scores 5 marks, five sets scores 4 marks etc.
Incorrect trend –1. Minor help from Supervisor –1. Major help from Supervisor –2.
[5]
Range:
amax – amin ⩾ 30.0 cm.
[1]
Column headings:
Each column heading must contain a quantity and a unit. The presentation of
quantity and unit must conform to accepted scientific convention. e.g. a / m or
a (m), 1/V / V–1.
[1]
Consistency:
All values of a and b must be given to the nearest mm.
[1]
Significant figures:
Every value of 1 / V must be given to the same number of significant figures as (or
one more than) the number of significant figures in the corresponding value of V.
[1]
Calculation:
Values of 1 / V calculated correctly to the number of significant figures given by
the candidate.
[1]
(d) (i) Axes:
Sensible scales must be used. Awkward scales (e.g. 3:10) are not allowed.
Scales must be chosen so that the plotted points occupy at least half the
graph grid in both x and y directions.
Scales must be labelled with the quantity that is being plotted.
Scale markings should be no more than three large squares apart.
[1]
Plotting:
All observations in the table must be plotted on the grid.
Diameter of plotted points must be ⩽ half a small square (no “blobs”).
Points must be plotted to an accuracy of half a small square.
[1]
Quality:
All points in the table must be plotted (at least 5) for this mark to be awarded.
Scatter of points must be no more than ± 0.050 m (5.0 cm) to scale in the b
direction from a straight line.
[1]
(ii) Line of best fit:
Judge by balance of all points on the grid about the candidate’s line (at least
5 points). There must be an even distribution of points either side of the line
along the full length.
Allow one anomalous point only if clearly indicated (i.e. circled or labelled) by
the candidate.
Lines must not be kinked or thicker than half a square.
[1]
© Cambridge International Examinations 2015
www.dynamicpapers.com
Page 3
Mark Scheme
Cambridge International AS/A Level – October/November 2015
Syllabus
9702
(iii) Gradient:
The hypotenuse of the triangle must be greater than half the length of the
drawn line. Do not allow ∆x / ∆y. Sign of gradient must match graph drawn.
Both read-offs must be accurate to half a small square in both the x and y
directions.
y-intercept:
Either:
Correct read-off from a point on the line substituted into y = mx + c or an
equivalent expression.
Read-offs must be accurate to half a small square in both x and y directions.
Or:
Intercept read directly from the graph, with read-off accurate to half a small
square.
2
Paper
35
[1]
[1]
(e) Value of P = candidate’s gradient and value of Q = candidate’s intercept.
[1]
Unit for P is correct (e.g. m–1 V–1) and unit for Q is correct (e.g. V–1).
[1]
(b) (iv) All values of x with unit to nearest mm. Average x ⩽ 20.0 cm.
[1]
(c) (i) Value of θ to the nearest degree in the range 25° to 35°.
[1]
(ii) Absolute uncertainty in θ in range 2° to 5° and correct method of calculation
to obtain percentage uncertainty. If repeated readings have been taken, then
the absolute uncertainty can be half the range (but not zero) if working is
clearly shown.
[1]
(iii) Correct calculation of cos2(θ / 2). No unit.
[1]
(iv) Justification for significant figures in cos2(θ / 2) linked to significant figures in θ.
[1]
(d) (ii) T in range 0.5 s to 2.5 s, with unit.
[1]
Evidence of repeat readings of T.
[1]
(f) Second value of θ.
[1]
Second values of T1 and T2.
[1]
Second value of T1 / T2 < first value of T1 / T2 when rounded to 2 s.f.
[1]
(g) (i) Two values of k calculated correctly.
(ii) Valid comment consistent with the calculated values of k, testing against a
criterion specified by the candidate.
© Cambridge International Examinations 2015
[1]
[1]
www.dynamicpapers.com
Page 4
Mark Scheme
Cambridge International AS/A Level – October/November 2015
Syllabus
9702
Paper
35
(h)
(i) Limitations (4 max.)
(ii) Improvements (4 max.)
Do not credit
A
Not enough readings to draw a
conclusion
Take more readings and plot a
graph/
obtain more k values and
compare
Few readings/
only one reading/
not enough readings
for an accurate result/
“repeat readings”
on its own/
take more readings
and (calculate)
average k
B
Difficult to measure θ or read
protractor with reason e.g. rod is
above protractor/rod obscures view
Improved method of measuring
θ e.g. shadow projection with
light above/thinner rod/rod with
smaller diameter/plumb-lines
hung from rod/larger
protractor/360° protractor
Just “difficult to
measure θ”/
smaller rod/
“protractor reads to
1°”
C
Oscillations or T affected by...
e.g. air movement
force on release
different forces
angle of release
unwanted modes of oscillation
Improved method of release e.g.
card gate
or
switch off air conditioning/close
windows/closed room
Release by
electromagnet/
cutting string/
damping/
air resistance/
friction
D
Large percentage uncertainty in
time/period T is short
Valid method to improve timing
e.g. use video with timer/frame
by frame/motion sensor and
position at side of cradle
or
Increase T by... e.g. heavier
nail/longer nail/string
Oscillations too fast/
high/low speed
camera/
video on its own/
human reaction time/
just “difficult to
determine time”/
fiducial marker
E
Valid problem linked to magnetism
e.g. nail weakly magnetised/metal
stand attracts nail/interference by
Earth’s magnetic field.
Valid method to overcome
problem linked with magnetism
e.g. stroke nail more times/use
of coil
Nail loses magnetism
Method of fixing
paper/protractor/magnets e.g.
tape/Blu-tack/draw protractor on
paper
Just “stick paper”
without method
F
© Cambridge International Examinations 2015