Physics (9702) · Oct/Nov 2015 · Mark scheme 34

Cambridge Physics (9702) mark scheme for paper 34, Oct/Nov 2015 — 9702/34/O/N/15, file 9702_w15_ms_34.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

CAMBRIDGE INTERNATIONAL EXAMINATIONS
Cambridge International Advanced Subsidiary and Advanced Level

MARK SCHEME for the October/November 2015 series

9702 PHYSICS
9702/34

Paper 3 (Advanced Practical Skills 2),
maximum raw mark 40

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of
the examination. It shows the basis on which Examiners were instructed to award marks. It does not
indicate the details of the discussions that took place at an Examiners’ meeting before marking began,
which would have considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner
Report for Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the October/November 2015 series for most
Cambridge IGCSE®, Cambridge International A and AS Level components and some
Cambridge O Level components.

® IGCSE is the registered trademark of Cambridge International Examinations.

www.dynamicpapers.com
Page 2

1

Mark Scheme
Cambridge International AS/A Level – October/November 2015

Syllabus
9702

(b) (i) Value of θ to the nearest degree and in the range 135° to 165°.
(ii) Value of L in range 5.0 to 10.0 cm, with unit.
(d) Six sets of readings of θ and L scores 5 marks, five sets scores 4 marks etc.
Incorrect trend –1. Help from Supervisor –1.

Paper
34
[1]
[1]

[5]

Range:
θmax ⩾ 160° and θmin ⩽ 140°.

[1]

Column headings:
Each column heading must contain a quantity and a unit. The presentation of
quantity and unit must conform to accepted scientific convention e.g. θ / °.
1/sin(θ – 90°) must have no unit.

[1]

Consistency:
All values of L must be given to the nearest mm.

[1]

Significant figures:
Every value of 1/sin(θ – 90°) must be given to 2 or 3 significant figures only.

[1]

Calculation:
Values of 1/sin(θ – 90°) calculated correctly to the number of significant figures
given by the candidate.

[1]

(e) (i) Axes:
Sensible scales must be used. Awkward scales (e.g. 3:10) are not allowed.
Scales must be chosen so that the plotted points occupy at least half the
graph grid in both x and y directions.
Scales must be labelled with the quantity that is being plotted.
Scale markings should be no more than three large squares apart.

[1]

Plotting:
All observations in the table must be plotted on the grid.
Diameter of plotted points must be ⩽ half a small square (no “blobs”).
Points must be plotted to an accuracy of half a small square.

[1]

Quality:
All points in the table must be plotted (at least 5) for this mark to be awarded.
Scatter of points must be no more than ±0.3 (to scale) cm in the L direction
from a straight line.

[1]

(ii) Line of best fit:
Judge by balance of all points on the grid about the candidate’s line (at least
5 points). There must be an even distribution of points either side of the line
along the full length.
Allow one anomalous point only if clearly indicated (i.e. circled or labelled) by
the candidate.
Lines must not be kinked or thicker than half a square.

[1]

© Cambridge International Examinations 2015

www.dynamicpapers.com
Page 3

Mark Scheme
Cambridge International AS/A Level – October/November 2015

Syllabus
9702

Paper
34

(iii) Gradient:
[1]
The hypotenuse of the triangle must be greater than half the length of the drawn line.
Do not allow ∆x / ∆y. Sign of gradient must match graph drawn.
Both read-offs must be accurate to half a small square in both the x and y
directions.
y-intercept:
Either:
Correct read-offs from a point on the line substituted into y = mx + c or an
equivalent expression.
Read-offs must be accurate to half a small square in both x and y directions.
Or:
Intercept read directly from the graph, with read-off accurate to half a small square.
(f) Value of a = candidate’s gradient and value of b = candidate’s intercept.
Unit for a is correct (e.g. cm–1) and no unit for b.
2

(a) (i) All values of d to nearest mm, with unit, in range 5 to 30 mm.
Value of l greater than value of d.
(ii) Correct calculation of V with consistent unit.

[1]

[1]
[1]
[1]
[1]
[1]

(b) Justification for significant figures in V linked to significant figures in d and l.

[1]

(c) (iii) t in range 5.00 s to 30.00 s, with unit.

[1]

Evidence of repeat readings of t.

[1]

(d) Absolute uncertainty in t in range 0.5 s to 5.0 s and correct method of calculation to
obtain percentage uncertainty. If repeated readings have been taken, then the
absolute uncertainty can be half the range (but not zero) if working is clearly shown.

[1]

(e) Second values of d and l.

[1]

(f)

Second value of t.

[1]

Second value of t < first value of t.

[1]

(i) Two values of k calculated correctly.

[1]

(ii) Valid comment consistent with the calculated values of k, testing against a
criterion specified by the candidate.

[1]

© Cambridge International Examinations 2015

www.dynamicpapers.com
Page 4

Mark Scheme
Cambridge International AS/A Level – October/November 2015

Syllabus
9702

Paper
34

(g)

(i) Limitations (4 max.)

(ii) Improvements (4 max.)

Do not credit

A

Not enough readings to draw a
conclusion

Take more readings and plot a
graph/
obtain more k values and
compare

Few readings/
only one reading/
not enough readings
for an accurate result/
“repeat readings”
on its own/
take more readings
and (calculate)
average k

B

d is small/large uncertainty in d

Improved method of measuring
d e.g. micrometer/vernier
calipers/digital calipers/travelling
microscope

Difficult to measure d/
parallax error/
“calipers” on its own/
use bigger/larger
components

C

Volume of component not accurate,
with reason e.g. component not
cylindrical/has groove.

Method to find volume of
component e.g. use liquid
displacement method

D

Difficult to judge/know/see when
LED goes out.

Use dark(ened) room/
light meter/
light sensor/
cardboard tube over LED/
voltmeter to measure time for
p.d. to fall below specific value

E

Poor/dirty/loose contacts

Method of cleaning contacts e.g.
iron wool

© Cambridge International Examinations 2015

Use video

Advertisement