Physics (9702) · Oct/Nov 2017 · Mark scheme 52

Cambridge Physics (9702) mark scheme for paper 52, Oct/Nov 2017 — 9702/52/O/N/17, file 9702_w17_ms_52.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

Cambridge Assessment International Education
Cambridge International Advanced Subsidiary and Advanced Level

PHYSICS

9702/52

Paper 5 Planning, Analysis and Evalution

October/November 2017

MARK SCHEME
Maximum Mark: 30

Published

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge International will not enter into discussions about these mark schemes.
Cambridge International is publishing the mark schemes for the October/November 2017 series for most
®
Cambridge IGCSE , Cambridge International A and AS Level components and some Cambridge O Level
components.

® IGCSE is a registered trademark.

This document consists of 7 printed pages.
© UCLES 2017

[Turn over

9702/52

Cambridge International AS/A Level – Mark Scheme
PUBLISHED

Question
1

October/November
www.dynamicpapers.com
2017

Answer

Marks

Defining the problem
x is the independent variable and V is the dependent variable or vary x and measure V

1

keep current (in the coil P) constant

1

Methods of data collection
labelled diagram showing both coils supported

1

two correct circuit diagrams for coil P and coil Q:
power supply connected to one coil and voltmeter/c.r.o. connected to other coil

1

method to determine x, e.g. use a ruler or drawn labelled horizontal ruler adjacent to coils with x indicated

1

method to measure x from centre of coil P to centre of coil Q, e.g. measure width of (each) coil and divide by 2 and add to
separation of coils

1

Method of analysis

© UCLES 2017

plots a graph of ln V against x [or log V against x etc.]

1

relationship valid if a straight line produced

1

k = –gradient

1

Page 2 of 7

9702/52

Cambridge International AS/A Level – Mark Scheme
PUBLISHED

Question

October/November
www.dynamicpapers.com
2017

Answer
Additional detail including safety considerations

© UCLES 2017

Marks
Max. 6

D1

do not touch hot coil/use gloves to position hot coil/heat-proof gloves to position coil

D2

use large current/number of turns/iron core (to produce large magnetic field/induced e.m.f.)

D3

use high frequency (to produce larger induced e.m.f.)

D4

use an a.c. power supply or signal generator (connected to coil P)

D5

keep the number of turns (on each coil) constant/frequency constant

D6

method described to check that current is constant, e.g. use an ammeter and variable resistor/variable power
supply

D7

repeat measurements of x for different parts of the coil and average

D8

method to position ruler horizontally to measure x described e.g. use a spirit level or same height from bench at
both ends

D9

method to keep coils parallel/co-axial e.g. adjust coil Q until maximum reading or use set square to ensure that
coils are at right angles to the axis

D10

lnV = −kx + lnV0

Page 3 of 7

9702/52

Cambridge International AS/A Level – Mark Scheme
PUBLISHED

Question
2(a)

2(b)

October/November
www.dynamicpapers.com
2017

Answer
gradient =

Marks
1

4 µ L2f 2
g

M/g

1
n2

850 ± 85 (90)

0.1 or 0.11 or 0.111 or 0.1111

500 ± 50

0.06 or 0.063 or 0.0625

300 ± 30

0.04 or 0.040 or 0.0400

200 ± 20

0.03 or 0.028 or 0.0278

150 ± 15 (20)

0.02 or 0.020 or 0.0204

100 ± 10

0.02 or 0.016 or 0.0156

2

First mark for uncertainties in first column correct.
Second mark for all second column correct.
2(c)(i)

2(c)(ii)

Six points plotted correctly.
Must be within half a small square. Diameter of points must be less than half a small square.

1

Error bars in M plotted correctly.
All error bars to be plotted. Length of bar must be accurate to less than half a small square and symmetrical.

1

Line of best fit drawn.
Line must not pass through plotted point (0.11, 850) or (0.111, 850).

1

If points are plotted correctly then lower end of line should pass between (0.032, 250) and (0.036, 250) and upper end of
line should pass between (0.098, 800) and (0.104, 800).
Worst acceptable line drawn (steepest or shallowest possible line).
All error bars must be plotted.

© UCLES 2017

Page 4 of 7

1

9702/52

Cambridge International AS/A Level – Mark Scheme
PUBLISHED

Question
2(c)(iii)

2(d)(i)

Answer

October/November
www.dynamicpapers.com
2017
Marks

Gradient determined with a triangle that is at least half the length of the drawn line.

1

uncertainty = gradient of line of best fit – gradient of worst acceptable line
or
uncertainty = ½ (steepest worst line gradient – shallowest worst line gradient)

1

µ determined correctly using gradient.

1

µ=

9.81
× gradient
4 × 1202 × 1.542

µ = 7.18123 × 10−5 × gradient

© UCLES 2017

µ determined using gradient and given to 2 or 3 significant figures.

1

µ determined using gradient and correct unit g m–1 and in the range 0.560–0.630 (g m–1).

1

Page 5 of 7

9702/52

Cambridge International AS/A Level – Mark Scheme
PUBLISHED

Question
2(d)(ii)

Answer
Percentage uncertainty in µ.

∆gradient
× 100
gradient

Maximum/minimum methods:

max µ =

min µ =

9.81× max gradient
4 × 1152 × 1.532

9.81× min gradient
4 × 1252 × 1.552

Correct substitution of numbers must be seen.

© UCLES 2017

Marks
1


0.01
5
∆gradient 
% uncertainty =  2 ×
+ 2×
+
 × 100
1.54
120 gradient 

% uncertainty = 9.63% +

October/November
www.dynamicpapers.com
2017

Page 6 of 7

9702/52

Cambridge International AS/A Level – Mark Scheme
PUBLISHED

Question
2(e)

Answer
M determined correctly using µ from (d)(i).

M=

October/November
www.dynamicpapers.com
2017
Marks
1

1802 × 1.542 × (d)(i)
= 7.833 × (d)(i)
9.81× 1000

Correct substitution of numbers must be seen.
Absolute uncertainty determined.

1

0.01
5 

% uncertainty =  2 ×
+ 2×
× 100 + (d)(ii) = 6.9% + (d)(ii)
1.54
180 

Correct substitution of numbers must be seen.
Maximum/minimum methods:

max M =

( 4 ×)1852 × 1.552 × max(d)(i) = 8.382 × max(d)(i)
( 4 ×) 9.81× 1000

4 ×)1752 × 1.532 × min(d)(i)
(
min M =
= 7.308 × min(d)(i)
( 4 ×) 9.81× 1000

© UCLES 2017

Page 7 of 7

Advertisement