Physics (9702) · Oct/Nov 2016 · Mark scheme 52
Cambridge Physics (9702) mark scheme for paper 52, Oct/Nov 2016 — 9702/52/O/N/16, file 9702_w16_ms_52.pdf.
Text of this paper
Cambridge International Examinations
Cambridge International Advanced Subsidiary and Advanced Level
PHYSICS
9702/52
Paper 5 Planning, Analysis and Evaluation
October/November 2016
MARK SCHEME
Maximum Mark: 30
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the October/November 2016 series for most
Cambridge IGCSE®, Cambridge International A and AS Level components and some Cambridge O Level
components.
® IGCSE is the registered trademark of Cambridge International Examinations.
This document consists of 5 printed pages.
© UCLES 2016
[Turn over
Page 2
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Question
1
Syllabus
9702
Paper
52
Answer
Marks
p is the independent variable and B is the dependent variable, or vary p and
measure B.
1
Keep the current/I (in the electromagnet) constant.
1
Defining the problem
Methods of data collection
Labelled diagram showing Hall probe correctly positioned (along p) and
ruler correctly positioned and either Hall probe or rule supported.
1
Correct circuit diagram to include d.c. power supply in series with coil and
ammeter. Must be a workable circuit diagram to measure current through
the coil.
1
Measure p with ruler.
1
Method to determine an accurate value of p.
1
Examples include:
Height of P above bench – height of electromagnet
Height of P measured from ruler across the top of the electromagnet
Method of analysis
Plot a graph of ln B against p.
1
α = – gradient
1
k=
1
e y −intercept
NI
© UCLES 2016
Page 3
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Question
Syllabus
9702
Answer
Additional detail including safety considerations
1. Keep the number of turns/N constant.
2. Use large number of turns/current (to increase B).
3. Avoid overheating the coil/do not touch hot coil.
4. Use of variable resistor to keep ammeter reading constant.
5. Method to ensure that Hall probe is equidistant from the poles, e.g.
determine centre of electromagnet and use of plumb line/ruler and spirit
level/set square.
6. Adjust Hall probe until maximum reading obtained/perpendicular to field.
7. Repeat each experiment for the same value of p and reverse the
current/Hall probe and average
8. ln B = –αp + ln kNI
9. Relationship is valid if the graph is a straight line.
10. Calibrate Hall probe using a known field.
© UCLES 2016
Paper
52
Marks
6
Page 4
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Question
2
(a)
(b)
Syllabus
9702
Answer
gradient = q
y-intercept = lg p
Paper
52
Marks
1
2.80 or 2.799 or 2.7993
0.28 or 0.279
2.79 or 2.792 or 2.7924
0.30 or 0.301
2.77 or 2.771 or 2.7709
0.36 or 0.362
2.72 or 2.716 or 2.7160
0.49 or 0.491
2.69 or 2.690 or 2.6902
0.57 or 0.568
2.67 or 2.672 or 2.6721
0.61 or 0.613
All first column correct – either 2 and 3 decimal places or 3 and 4 decimal
places.
1
All second column correct. Allow a mixture of decimal places.
1
Uncertainties in lg (V / V) from ± 0.02 to ± 0.01. Allow more than one
significant figure.
1
(c) (i) Six points plotted correctly.
Must be within half a small square. No “blobs”.
All error bars in lg (V / V) plotted correctly.
All error bars to be plotted. Total length of bar must be accurate to less than
half a small square and symmetrical.
(ii) Line of best fit drawn.
Line must not be drawn from top point to bottom point unless points are
balanced.
Upper end of line should pass between (2.694, 0.55) and (2.700, 0.55) and
lower end of line should pass between (2.770, 0.35) and (2.776, 0.35).
Worst acceptable line drawn correctly.
Steepest or shallowest possible line that passes through all the error bars.
Mark scored only if all error bars are plotted.
(iii) Gradient determined with a triangle that is at least half the length of the drawn
line.
Read-offs must be accurate to half a small square.
Gradient must be negative.
Method of determining absolute uncertainty.
uncertainty = gradient of line of best fit – gradient of worst acceptable line
or
uncertainty = ½(steepest worst line gradient – shallowest worst line gradient)
© UCLES 2016
1
1
1
1
1
1
Page 5
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Question
Syllabus
9702
Answer
(iv) y-intercept determined by substitution into y = mx + c.
Read-offs must be accurate to half a small square.
(d)
(e)
Paper
52
Marks
1
Method of determining absolute uncertainty.
uncertainty = y-intercept of line of best fit – y-intercept of worst acceptable
line
or
uncertainty = ½(steepest worst line y-intercept – shallowest worst line
y-intercept)
No ECF from false origin method.
1
Use of p = 10answer to 2(c)(iv)
or
lg p = answer to 2(c)(iv)
1
q = gradient and in the range –2.50 to –2.70 and given to 2 or 3 s.f.
1
Use of V = p × 950q
or
lg V = q lg 950 + lg p
or
lg V = q lg 950 + y-intercept
1
Correct substitution of numbers must be seen to give V.
© UCLES 2016