Physics (9702) · Oct/Nov 2016 · Mark scheme 34
Cambridge Physics (9702) mark scheme for paper 34, Oct/Nov 2016 — 9702/34/O/N/16, file 9702_w16_ms_34.pdf.
Text of this paper
Cambridge International Examinations
Cambridge International Advanced Subsidiary and Advanced Level
PHYSICS
9702/34
Paper 3 Advanced Practical Skills 2
October/November 2016
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the October/November 2016 series for most
Cambridge IGCSE®, Cambridge International A and AS Level components and some Cambridge O Level
components.
® IGCSE is the registered trademark of Cambridge International Examinations.
This document consists of 4 printed pages.
© UCLES 2016
[Turn over
Page 2
1
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Syllabus
9702
Paper
34
(b) (ii) Value for x in range 24.0 cm to 26.0 cm, with unit.
(iv) Value for T in range 0.30 s to 1.00 s.
Evidence of repeat readings (at least two recordings of nT where n ⩾ 5).
(c) Six sets of values for x and T (with correct trend and without help from Supervisor)
scores 4 marks, five sets scores 3 marks etc.
[1]
[1]
[1]
[4]
Range:
xmin ⩽ 20.0 cm and xmax ⩾ 30.0 cm.
[1]
Column headings:
Each column heading must contain a quantity and an appropriate unit. The
presentation of the quantity and unit must conform to accepted scientific convention
e.g. 1 / T2 (s–2) or 1 / T2 / 1 / s2.
[1]
Consistency:
All values of x must be given to the nearest mm.
[1]
Significant figures:
Every value of 1/T2 must be given to the same number of s.f. as (or one greater than)
the number of s.f. in the corresponding times.
[1]
Calculation:
Values of 1/T 2 calculated correctly to the number of s.f. given by the candidate.
[1]
(d) (i) Axes:
Sensible scales must be used. Awkward scales (e.g. 3:10, fractions or nonlinear) are not allowed.
Scales must be chosen so that the plotted points occupy at least half the graph
grid in both x and y directions
Scales must be labelled with the quantity that is being plotted.
Scale markings must be no more than three large squares apart.
[1]
Plotting of points:
All observations in the table must be plotted on the grid.
Diameter of plotted points must be ⩽ half a small square (no “blobs”).
Points must be plotted to an accuracy of half a small square.
[1]
Quality:
All points in the table must be plotted (at least 5) for this mark to be awarded.
All points must be within ± 1.0 cm (to scale) of a straight line in the x direction.
[1]
(ii) Line of best fit:
Judge by balance of all points on the grid about the candidate's line (at
least 5 points). There must be an even distribution of points either side of the line
along the full length.
Allow one anomalous plot if clearly indicated (i.e. circled or labelled) by the
candidate. There must be at least five points left after the anomalous point is
disregarded.
Line must not be kinked or thicker than half a small square.
[1]
© UCLES 2016
Page 3
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Syllabus
9702
Paper
34
(iii) Gradient:
The hypotenuse of the triangle must be greater than half the length of the
drawn line.
The method of calculation must be correct. Do not allow ∆x / ∆y.
Both read-offs must be accurate to half a small square in both the x and y
directions.
y-intercept:
Either:
Check correct read-off from a point on the line and substituted into y = mx + c.
Read-off must be accurate to half a small square in both x and y directions.
Or:
Check read-off of the intercept directly from the graph (accurate to half a
small square.
(e) Value of p = candidate’s gradient and value of q = candidate’s intercept.
Do not allow fractions.
Units for p (e.g. cm–1 s–2) and q (e.g. s–2) correct.
2
[1]
[1]
[1]
[1]
(b) L in range 19.0 cm to 21.0 cm, with unit.
[1]
(c) (iv) Values for x1 and x2 to nearest mm and x2 > x1.
[1]
Evidence of repeat readings of x1 and x2.
(v) Correct calculation of X.
[1]
[1]
(d) Absolute uncertainty in X in range 2 mm to 10 mm.
If repeated readings have been taken, then absolute uncertainty can be half the
range (but not zero) if working is clearly shown.
Correct method of calculation to obtain percentage uncertainty.
[1]
(e) Second value for L.
[1]
(f)
Second values for x1 and x2.
[1]
Quality: X smaller for larger L.
[1]
(i) Two values of k calculated correctly.
[1]
(ii) Justification of s.f. in k based on the s.f. in L, x1 and x2.
[1]
(iii) Valid comment consistent with the calculated values of k, testing against a stated
numerical criterion.
[1]
(g) Value for X = 50 cm.
[1]
© UCLES 2016
Page 4
(h)
A
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Syllabus
9702
Paper
34
(i) Limitations [4]
(ii) Improvements [4]
Do not credit
Two readings not enough to draw
a conclusion
Take more readings and plot
graph/
obtain more k values and
compare
Two readings not
enough for accurate
results
Repeat readings
Few readings
Take more readings and
calculate average k
B
Metre rule is not parallel to
bench/horizontal
Use a second rule and measure
at both ends/
use a (spirit) level
C
Difficult to move stands with
reason e.g. friction/
bench is rough/
stands tend to stick
Guide for stands (fixed to
bench)/
mount stands on rollers/
put wheels on stands/
method to reduce friction e.g.
sand bench with sandpaper
Use a smooth(er) bench
D
Difficulty with rule
e.g. rule skewed/
moves sideways
Use V-shaped rods/
groove in rods/
guide for ruler with some details
Falls off
E
Difficult to measure x with reason
e.g parallax error/
difficult to tell point where rod
touches ruler
Scale on vertical edge of rule/
draw a line on the rod/
use a thinner rod/
replace rods with sharp edges
e.g. prisms
Large contact area
Do not allow ‘use a computer to improve the experiment’.
© UCLES 2016
Use lubricant