Physics (9702) · Oct/Nov 2016 · Mark scheme 33
Cambridge Physics (9702) mark scheme for paper 33, Oct/Nov 2016 — 9702/33/O/N/16, file 9702_w16_ms_33.pdf.
Text of this paper
Cambridge International Examinations
Cambridge International Advanced Subsidiary and Advanced Level
PHYSICS
9702/33
Paper 3 Advanced Practical Skills 1
October/November 2016
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the October/November 2016 series for most
Cambridge IGCSE®, Cambridge International A and AS Level components and some Cambridge O Level
components.
® IGCSE is the registered trademark of Cambridge International Examinations.
This document consists of 4 printed pages.
© UCLES 2016
[Turn over
Page 2
1
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Syllabus
9702
Paper
33
(a) (v) Value of I in range 20 mA ⩽ I ⩽ 200 mA with unit.
[1]
(c) Six sets of readings of R and y (with correct trend and without help from Supervisor)
scores 5 marks, five sets scores 4 marks etc.
[5]
Range:
Values of R must include 33 Ω.
[1]
Column headings:
Each column heading must contain a quantity and a unit where appropriate.
The presentation of the quantity and unit must conform to accepted scientific
convention, e.g. 1 / y / m–1 or 1 / y (m–1).
[1]
Consistency:
All values of raw y must be given to the nearest mm.
[1]
Significant figures:
Every value of 1 / R must be given to 2 or 3 significant figures.
[1]
Calculation:
1 / y calculated correctly to the number of s.f. given by the candidate.
[1]
(d) (i) Axes:
Sensible scales must be used. Awkward scales (e.g. 3:10, fractions or non-linear)
are not allowed.
Scales must be chosen so that the plotted points occupy at least half the graph
grid in both x and y directions.
Scales must be labelled with the quantity that is being plotted.
Scale markings should be no more than three large squares apart.
[1]
Plotting of points:
All observations must be plotted on the grid.
Diameter of plotted points must be ⩽ half a small square (no “blobs”).
Plotted points must be accurate to half a small square.
[1]
Quality:
All points in the table must be plotted on the grid for this mark to be awarded.
All points must be within 0.001 cm–1 (0.1 m–1) (to scale) on the y-axis of a
straight line.
[1]
(ii) Line of best fit:
Judge by balance of all points on the grid about the candidate’s line (at least
5 points). There must be an even distribution of points either side of the line
along the full length.
Allow one anomalous point only if clearly indicated (i.e. circled or labelled) by
the candidate. There must be at least five points left after the anomalous
point is disregarded.
Line must not be kinked or thicker than half a small square.
[1]
© UCLES 2016
Page 3
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Syllabus
9702
(iii) Gradient:
The hypotenuse of the triangle must be greater than half the length of the
drawn line.
The method of calculation must be correct. Do not allow ∆x / ∆y.
Both read-offs must be accurate to half a small square in both the x and y
directions.
y-intercept:
Either:
Check correct read-off from a point on the line and substituted into y = mx + c.
Read-off must be accurate to half a small square in both x and y directions.
Or:
Check read-off of the intercept directly from the graph (accurate to half a
small square.
(e) Value of P = – candidate’s gradient and value of Q = candidate’s intercept.
Do not allow fractions.
Units for P (e.g. Ω m–1) and Q (e.g. m–1) correct.
2
Paper
33
[1]
[1]
[1]
[1]
(f) (ii) Value of X in the range 5.0 Ω to 20.0 Ω from correct calculation.
[1]
(b) (iii) All raw readings stated to at least 0.1 s. Value for T with unit in the range
0.50 s to 0.90 s.
[1]
Evidence of repeats (at least two recordings of nT where n ⩾ 5).
[1]
(c) (i) Correct calculation of l.
[1]
(ii) Justification of s.f. in l linked to s.f. in time readings (e.g. time, raw time, nT).
(d) (ii) Value of d (l ± 0.050 m).
[1]
[1]
(iii) Absolute uncertainty in d in range 2 mm–8 mm.
If repeated readings have been taken, then the uncertainty can be half the
range (but not zero) if the working is clearly shown.
Correct method of calculation to obtain percentage uncertainty.
[1]
(e) (ii) Value for t in the range 2.0 s–8.0 s.
[1]
(f) Second value of T.
[1]
Second value of t.
[1]
Quality: Second value of t > first value of t.
[1]
© UCLES 2016
Page 4
Mark Scheme
Cambridge International AS/A Level – October/November 2016
Syllabus
9702
Paper
33
(g) (i) Two values of k calculated correctly, and to at least 2 significant figures.
(ii) Valid comment consistent with calculated values of k, testing against a stated
numerical criterion.
(h)
A
(i) Limitations [4]
(ii) Improvements [4]
Do not credit
Two readings not enough to draw a
conclusion
Take many readings (for
different masses) and plot a
graph/
take more readings and
compare k values
Two readings not
enough for accurate
results
[1]
[1]
Repeat readings
Few readings
Take more readings and
calculate average k
B
Difficult to set d with reason e.g.
knot takes some string/knot or
weight slips
Improved method to set d e.g.
trial and error/glue knots to stop
slipping
C
Difficult to measure d with reason
e.g. parallax error/cannot get ruler
close/hands move holding ruler in
place/difficult to judge centre of
mass(es)/rule not vertical
Clamped metre rule/
measure to top and bottom of
masses and find the average/
detailed method to check rule
vertical/
detailed method to reduce
parallax error
Eyes level
Eyes perpendicular
Difficult to measure (n)T with
reason e.g. difficult to judge
complete oscillation
Use fiducial marker at centre of
oscillation/
use a motion sensor placed
under masses
Reaction time error
E
Difficult to see when coil separation
is constant
or
Separation of coils constant for a
short time
Video with timer/
video and view frame by frame/
screen behind spring
Video timer
F
Movement of spring along rod
Method to fix spring to rod e.g.
Blu-Tack or groove in rod
Air conditioning/draughts
D
Reference to set square
without detail
Force on release
Unwanted modes of
oscillation
© UCLES 2016