Physics (9702) · Oct/Nov 2016 · Mark scheme 31

Cambridge Physics (9702) mark scheme for paper 31, Oct/Nov 2016 — 9702/31/O/N/16, file 9702_w16_ms_31.pdf.

Advertisement
Loading the paper…
Text of this paper

Cambridge International Examinations
Cambridge International Advanced Subsidiary and Advanced Level

PHYSICS

9702/31

Paper 3 Advanced Practical Skills 1

October/November 2016

MARK SCHEME
Maximum Mark: 40

Published

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the October/November 2016 series for most
Cambridge IGCSE®, Cambridge International A and AS Level components and some Cambridge O Level
components.

® IGCSE is the registered trademark of Cambridge International Examinations.

This document consists of 4 printed pages.
© UCLES 2016

[Turn over

Page 2
1

Mark Scheme
Cambridge International AS/A Level – October/November 2016

Syllabus
9702

Paper
31

(b) Value for T in the range 0.60 s to 0.80 s with unit.
Evidence of repeat timings (at least two recordings of nT where n ⩾ 5).
(c) Correct calculation of k.

[1]
[1]

Value of k must be given to the same number of s.f. as (or one more than) the s.f.
in the values of the raw times.
(e) Six sets of readings of (h – h1) and T (with correct trend and without help from
Supervisor) scores 5 marks, five sets scores 4 marks etc.

(f)

[1]

[1]

[5]

Range:
∆(h – h1) ⩾ 30.0 cm.

[1]

Column headings:
Each column heading must contain a quantity and a unit where appropriate.
The presentation of the quantity and unit must conform to accepted scientific
convention, e.g. T / s or T (s).

[1]

Consistency:
All values of (h – h1) must be given to the nearest mm.

[1]

(i) Axes:
Sensible scales must be used. Awkward scales (e.g. 3:10, fractions or non-linear)
are not allowed.
Scales must be chosen so that the plotted points occupy at least half the graph
grid in both x and y directions.
Scales must be labelled with the quantity that is being plotted.
Scale markings should be no more than three large squares apart.

[1]

Plotting of points:
All observations must be plotted on the grid.
Diameter of plotted points must be ⩽ half a small square (no “blobs”).
Points must be plotted to an accuracy of half a small square.

[1]

Quality:
All points in the table must be plotted on the grid for this mark to be awarded.
All points must be within 0.01 s on the y-axis of a straight line.

[1]

(ii) Line of best fit:
Judge by balance of all points on the grid about the candidate’s line (at least
5 points). There must be an even distribution of points either side of the line
along the full length.
Allow one anomalous point only if clearly indicated (i.e. circled or labelled) by
the candidate. There must be at least five points left after the anomalous
point is disregarded.
Line must not be kinked or thicker than half a small square.

[1]

© UCLES 2016

Page 3

Mark Scheme
Cambridge International AS/A Level – October/November 2016

Syllabus
9702

(iii) Gradient:
The hypotenuse of the triangle must be greater than half the length of the
drawn line.
The method of calculation must be correct. Do not allow ∆x / ∆y.
Both read-offs must be accurate to half a small square in both the x and y
directions.
y-intercept:
Either:
Check correct read-off from a point on the line and substituted into y = mx + c.
Read-off must be accurate to half a small square in both x and y directions.
Or:
Check read-off of the intercept directly from the graph (accurate to half a
small square.
(g) Value of P = candidate’s gradient and value of Q = candidate’s intercept.
Do not allow fractions.
Units for P (e.g. s m–1 or s cm–1 or s mm–1) and Q (s) correct.
2

(a) (i) Value for D with unit in the range 0.14 mm to 0.16 mm.

Paper
31
[1]

[1]

[1]
[1]
[1]

(ii) Percentage uncertainty in D based on an absolute uncertainty of 0.01 mm.
Correct method of calculation to obtain percentage uncertainty.

[1]

(c) (iii) Value of I in range 10 mA ⩽ I ⩽ 200 mA with unit (collected without help from
Supervisor).

[1]

(iv) Value of V in range 0.4 V ⩽ V ⩽ 1.0 V with unit (collected without help from
Supervisor).

[1]

(d) (i) Value of d > D and d < 1 mm.

[1]

(ii) Correct calculation of G.

[1]

(iii) Justification for s.f. in G linked to s.f. in D and d.

[1]

(f)

(i) Second value of V.

[1]

Quality: second value of V less than first value of V.
(ii) Second value of d.

[1]
[1]

© UCLES 2016

Page 4

Mark Scheme
Cambridge International AS/A Level – October/November 2016

Syllabus
9702

Paper
31

(g) (i) Two values of k calculated correctly, and to at least 2 significant figures.
(ii) Valid comment consistent with calculated values of k, testing against a stated
numerical criterion.

(h)
A

(i) Limitations [4]

(ii) Improvements [4]

Do not credit

Two readings not enough to draw a
conclusion

Take many readings (for
different diameters) and plot a
graph/
take more readings and
compare k values

Two readings not
enough for accurate
results

[1]
[1]

Repeat readings
Few readings
Take more readings and
calculate average k

B

Difficult to measure diameter(s)
with reason e.g. awkward placing
micrometer round wire/
only one direction to measure
diameter

Provide separate lengths of wire

C

Meter readings changed in a
particular direction over time/
repeat readings of I or V were
often different/
contact resistance varies

Use power supply/
allow reading to reach steady
value/
method of cleaning crocodile
clips or wires

D

Wire is very thin introducing a large
percentage error in the diameter

Use thicker wire/
use digital micrometer

E

Rheostat movement not precise
enough – overshot I reading

Method to ensure exact current
easier to produce e.g. use of
screw thread adjustment

© UCLES 2016

Advertisement