Physics (9702) · May/June 2015 · Mark scheme 33
Cambridge Physics (9702) mark scheme for paper 33, May/June 2015 — 9702/33/M/J/15, file 9702_s15_ms_33.pdf.
Text of this paper
www.dynamicpapers.com
CAMBRIDGE INTERNATIONAL EXAMINATIONS
Cambridge International Advanced Subsidiary and Advanced Level
MARK SCHEME for the May/June 2015 series
9702 PHYSICS
9702/33
Paper 3 (Advanced Practical Skills 1),
maximum raw mark 40
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of
the examination. It shows the basis on which Examiners were instructed to award marks. It does not
indicate the details of the discussions that took place at an Examiners’ meeting before marking began,
which would have considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner
Report for Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2015 series for most
Cambridge IGCSE®, Cambridge International A and AS Level components and some
Cambridge O Level components.
® IGCSE is the registered trademark of Cambridge International Examinations.
www.dynamicpapers.com
Page 2
1
Mark Scheme
Cambridge International AS/A Level – May/June 2015
Syllabus
9702
Paper
33
(b) (iv) Value of y in the range 10.0 cm to 11.0 cm with unit.
[1]
(c) (ii) Value of y > value in (b)(iv).
[1]
(d) Six sets of readings of m and y scores 5 marks, five sets scores 4 marks etc.
Help from Supervisor –1.
[5]
Range:
Range of m to include m = 0 g and m = 50 g or 60 g.
[1]
Column headings:
Each column heading must contain a quantity and a unit where appropriate.
The unit must conform to accepted scientific convention e.g. y(C + m) / cm g.
[1]
Consistency:
All values of raw y must be given to the nearest mm.
[1]
Significant figures:
Every value of value of y(C + m) must be given to the same number of s.f. as (or one
more than) the least s.f. in the corresponding values of y, C and m as stated in the
candidate’s table and (a)(ii).
[1]
Calculation:
Values of y(C + m) calculated correctly to the number of s.f. given by the candidate.
[1]
(e) (i) Axes:
Sensible scales must be used. Awkward scales (e.g. 3:10) are not allowed.
Scales must be chosen so that the plotted points occupy at least half the graph grid
in both x and y directions.
Scales must be labelled with the quantity that is being plotted.
Scale markings should be no more than three large squares apart.
[1]
Plotting:
All observations must be plotted.
Diameter of plotted points must be ≤ half a small square (no “blobs”).
Plotted points must be accurate to within half a small square.
[1]
Quality:
All points in the table (at least 5) must be plotted on the grid for this mark to be
awarded.
All points must be within ± 40 g cm of a straight line in the y(C + m) direction.
[1]
(ii) Line of best fit:
[1]
Judge by balance of all points on the grid about the candidate’s line (at least 5
points). There must be an even distribution of points either side of the line along the
full length.
Allow one anomalous point only if clearly indicated by the candidate.
Lines must not be kinked or thicker than half a square.
© Cambridge International Examinations 2015
www.dynamicpapers.com
Page 3
Mark Scheme
Cambridge International AS/A Level – May/June 2015
Syllabus
9702
Paper
33
(iii) Gradient:
[1]
The hypotenuse of the triangle must be greater than half the length of the drawn line.
The method of calculation must be correct.
Both read-offs must be accurate to half a small square in both the x and y directions.
y-intercept:
Either:
Correct read-offs from a point on the line and substituted into y = mx + c.
Read-offs must be accurate to half a small square in both x and y directions.
Or:
Check read-off of the intercept directly from the graph
(accurate to half a small square).
(f) Value of A = candidate’s gradient and value of B = 2 × candidate’s intercept / A.
Do not allow fractions or final answer to 1 s.f.
2
[1]
[1]
Unit for A (m, cm or mm) and B (g or kg) correct and consistent with value, with
correct power of ten.
[1]
(a) (i) Raw values of d and D to nearest 0.1 mm and with consistent SI unit, in ranges:
10.0 mm ≤=d ≤ 25.0 mm
20.0 mm ≤ D ≤ 40.0 mm.
[1]
(ii) Value of h with consistent unit in range 40.0 mm ≤ h ≤ 60.0 mm.
[1]
(iii) Percentage uncertainty in d based on absolute uncertainty of 0.1 or 0.2 mm.
If repeated readings have been taken, then the uncertainty can be half the range
(but not zero) if the working is clearly shown.
Correct method of calculation to obtain percentage uncertainty.
[1]
(b) (iii) Correct calculation of x. Answer must be correct when rounded to 2 s.f.
[1]
(c) Correct justification of s.f. in x linked to s.f. in D, d and h.
[1]
(d) (ii) Value of average t ≥ 0.5 s with unit.
[1]
Evidence of repeated readings (here or in (e)).
[1]
(e) Second value of x.
[1]
Second value of t.
[1]
Second value of t < first value of t.
[1]
(i) Two values of k calculated correctly.
[1]
(ii) Sensible comment relating to the calculated values of k, testing against a criterion
specified by the candidate.
[1]
(f)
© Cambridge International Examinations 2015
www.dynamicpapers.com
Page 4
(g)
Mark Scheme
Cambridge International AS/A Level – May/June 2015
Syllabus
9702
Paper
33
(i) Limitations (4 max.)
(ii) Improvements (4 max.)
Do not credit
A
Two readings not enough to draw
a valid conclusion
Take many readings and plot
a graph/
take more readings and
compare k values.
“repeat readings”/
“too few readings”
B
Difficulty in release of cylinder
from same position every time
with reason, e.g. placing fingers in
water, level of water surface
changing, difficult to judge start
point
Better method of holding and
releasing cylinder e.g. stop
gate/
use mark to ensure the water
level is the same for each
release
Clamps
Force on release
C
Cylinder doesn’t always fall
vertically (i.e. path at an angle or
cylinder tilted)/
hits sides on descent
Method of attaching string
symmetrically/
method of symmetrical
distribution of mass
e.g. use glass beads or sand/
modelling clay distributed
evenly/
glue marbles in symmetrically
Ignore string effects
Sand on its own
Narrow cylinder
D
Times short/
large uncertainty in time
Use longer tube/
video with timer (or video and
view frame by frame)
Reaction time is short
“too fast/quick”
High speed camera
Light gate(s)
Slow motion camera
Terminal velocity
E
Difficulty in identifying end point
with reason e.g. refraction, glass
curvature, tray in the way, bottom
of cylinder not flat
Method to identify end point
e.g. time to a mark on
cylinder/listening to impact
Flat bottomed cylinder
Sensors
F
Limited number of marbles to fit in
container/
different diameter marbles/
bubbles or air in container/
container deforms when
measuring D
Use different shapes e.g.
cubes/smaller spheres to
occupy more space/
use sand/modelling clay to fill
more space/
measure and account for
different diameter of marbles
in equation for x
Sand on its own without
explanation
© Cambridge International Examinations 2015