Physics (9702) · May/June 2015 · Mark scheme 32

Cambridge Physics (9702) mark scheme for paper 32, May/June 2015 — 9702/32/M/J/15, file 9702_s15_ms_32.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

CAMBRIDGE INTERNATIONAL EXAMINATIONS
Cambridge International Advanced Subsidiary and Advanced Level

MARK SCHEME for the May/June 2015 series

9702 PHYSICS
9702/32

Paper 3 (Advanced Practical Skills 2),
maximum raw mark 40

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of
the examination. It shows the basis on which Examiners were instructed to award marks. It does not
indicate the details of the discussions that took place at an Examiners’ meeting before marking began,
which would have considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner
Report for Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2015 series for most
Cambridge IGCSE®, Cambridge International A and AS Level components and some
Cambridge O Level components.

® IGCSE is the registered trademark of Cambridge International Examinations.

www.dynamicpapers.com
Page 2
1

Mark Scheme
Cambridge International AS/A Level – May/June 2015

Syllabus
9702

Paper
32

(c) (ii) Value of h in the range 45.0 to 55.0 cm.
(iii) Value of x less than 50.0 cm.
(d) Six sets of readings of x and h scores 5 marks, five sets scores 4 marks etc.
Incorrect trend –1. Help from Supervisor –1.

[1]
[1]
[5]

Range:
xmax – xmin ≥ 60.0 cm.

[1]

Column headings:
Each column heading must contain a quantity and a unit where appropriate. The
presentation of quantity and unit must conform to accepted scientific convention.
e.g. 1 / h / cm–1. x / h must have no unit.

[1]

Consistency:
All values of h and all values of x must be given to the nearest mm.

[1]

Significant figures:
[1]
Every value of x / h must be given to the same number of s.f. (or one more than) the least
number of s.f. in the corresponding values of x and h as recorded in table.
Calculation:
Values of x / h calculated correctly.
(e) (i) Axes:
Sensible scales must be used. Awkward scales (e.g. 3:10) are not allowed.
Scales must be chosen so that the plotted points occupy at least half the graph
grid in both x and y directions.
Scales must be labelled with the quantity that is being plotted.
Scale markings should be no more than three large squares apart.

[1]

[1]

Plotting:
All observations must be plotted on the grid. Diameter of plotted points must
be ≤ half a small square (no “blobs”).
Plotted points must be accurate to within half a small square in both x and y
directions.

[1]

Quality:
All points in the table must be plotted (at least 5) for this mark to be awarded.
Scatter of points must be no more than ± 0.1 from a straight line in the x / h
direction.

[1]

(ii) Line of best fit:
Judge by balance of all points on the grid about the candidate’s line (at least 5
points). There must be an even distribution of points either side of the line along
the full length.
Allow one anomalous point only if clearly indicated (i.e. circled or labelled) by the
candidate.
Lines must not be kinked or thicker than half a square.

[1]

© Cambridge International Examinations 2015

www.dynamicpapers.com
Page 3

Mark Scheme
Cambridge International AS/A Level – May/June 2015

Syllabus
9702

Paper
32

(iii) Gradient:
[1]
The hypotenuse of the triangle must be greater than half the length of the drawn line.
The method of calculation must be correct.
Both read-offs must be accurate to half a small square in both the x and y directions.
y-intercept:
Either:
Correct read-offs from a point on the line and substituted into y = mx + c or an
equivalent expression.
Both read-offs accurate to half a small square in both the x and y directions.
Or:
Intercept read directly from the graph, with read-off at x = 0 accurate to half a small
square in y direction.
(f) Value of a = candidate’s gradient and value of b = candidate’s intercept.
Units for a and b both correct and consistent with values.
2

(a) (ii) All values of D to nearest 0.1 cm and in range 2.0 cm to 4.0 cm.
Evidence of repeat readings of D.

[1]

[1]
[1]
[1]
[1]

(iii) Absolute uncertainty in D in range 0.2 to 0.5 cm and correct method of calculation
to obtain percentage uncertainty. If repeated readings have been taken, then the
absolute uncertainty can be half the range (but not zero) if the working is clearly
shown.

[1]

(iv) Correct calculation of C with consistent unit.

[1]

(b) Justification for significant figures in C linked to significant figures in D only.

[1]

(d) (ii) r1 in range 5.0 cm to 25.0 cm, with unit, to nearest mm.

[1]

(v) r2 in range 5.0 cm to 25.0 cm.
(e) Second value of D.

(f)

[1]
[1]

Second values of r1 and r2.

[1]

Second value of |r1 – r2| > first value of |r1 – r2|.

[1]

(i) Two values of k calculated correctly.

[1]

(ii) Sensible comment relating to the calculated values of k, testing against a
criterion specified by the candidate.

[1]

© Cambridge International Examinations 2015

www.dynamicpapers.com
Page 4

(g)

Mark Scheme
Cambridge International AS/A Level – May/June 2015

Syllabus
9702

Paper
32

(i) Limitations (4 max.)

(ii) Improvements (4 max.)

Do not credit

A

Two readings are not enough to
draw a valid conclusion.

Take more readings and plot a
graph/
obtain more k values and
compare

“repeat readings”/
“few readings”/
only one reading/
take more readings
and (calculate)
average k

B

Difficult to measure D (or there is
uncertainty in D or C) because loop
is not circular/not flat/deforms

Workable method of making a
more circular loop, e.g. wrap
loop around tube

Use micrometer
Use vernier calipers
Material weak
Material flexible

C

Parallax error with pointer/
pointer moves away from scale/
pointer (or spring) vibrates

Use shadow method

D

Ruler not vertical

Use set square to ensure ruler
vertical/clamp ruler

E

Difficult to judge reading when loop
breaks away/
loop breaks away suddenly

Video with scale/
use maximum marker

Slow motion camera
High speed camera
Difficult to determine
point (or moment)
loop breaks away

F

Difficult to lower beaker steadily

Use adjustable-height stand

G

Reading affected by contact
between loop and beaker/
impurities in water

Use larger diameter container/
wider container
Use distilled water

© Cambridge International Examinations 2015

Larger beaker

Advertisement