MARK SCHEME for the May/June 2015 series

9702 PHYSICS
9702/31

Paper 1 (Advanced Practical Skills 1),
maximum raw mark 40

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of
the examination. It shows the basis on which Examiners were instructed to award marks. It does not
indicate the details of the discussions that took place at an Examiners’ meeting before marking began,
which would have considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner
Report for Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2015 series for most
Cambridge IGCSE®, Cambridge International A and AS Level components and some
Cambridge O Level components.

® IGCSE is the registered trademark of Cambridge International Examinations.

www.dynamicpapers.com
Page 2
1

Mark Scheme
Cambridge International AS/A Level – May/June 2015

Syllabus
9702

Paper
31

(a) (ii) Value of w with unit, in range 45.0 cm to 55.0 cm.

[1]

(c) (iii) Value of IB, with unit, to nearest 0.1 mA, in range 70.0 ≤ IB ≤ 100.0 mA.

[1]

(d) Six sets of readings of w, IA and IB, different values, scores 5 marks,
five sets scores 4 marks, etc.
Incorrect trend –1.
Major help from Supervisor –2. Minor help from Supervisor –1.

[5]

Range:
Range of w ≥ 60.0 cm.

[1]

Column headings:
Each column heading must contain a quantity and a unit.
The presentation of quantity and unit must conform to accepted scientific
convention e.g. w / cm, w (cm), (IA+IB) / (IAIB) / A–1, (IA+IB) / (IAIB) / (1/A).
Do not allow (IA+IB) / (IAIB) / (A / A2).

[1]

Consistency:
All values of w must be given to the nearest mm only.

[1]

Significant figures:
Every value of (IA+IB) / (IAIB) must be given to the same number of s.f. as (or one
more than) the least s.f. in the corresponding values of IA and IB.

[1]

Calculated values:
Values of (IA+IB) / (IAIB) calculated correctly to the number of significant figures
given by the candidate.

[1]

(e) (i) Axes:
Sensible scales must be used. Awkward scales (e.g. 3:10) are not allowed.
Scales must be chosen so that the plotted points occupy at least half the graph grid
in both x and y directions.
Scales must be labelled with the quantity that is being plotted.
Scale markings should be no more than three large squares apart.

[1]

Plotting of points:
All observations in the table must be plotted.
Diameter of points must be ≤ half a small square (no “blobs”).
Plotted points must be accurate to within half a small square.

[1]

Quality:
All points in the table must be plotted on the grid (at least 5) for this mark to
be awarded.
All points must be within ± 5 cm (± 0.05 m) on the w-axis from a straight line.

[1]

(ii) Line of best fit:
[1]
Judge by balance of all points on the grid about the candidate’s line (at least 5
points). There must be an even distribution of points either side of the line along the
full length.
Allow one anomalous point only if clearly indicated by the candidate.
Lines must not be kinked or thicker than half a square.
© Cambridge International Examinations 2015

www.dynamicpapers.com
Page 3

Mark Scheme
Cambridge International AS/A Level – May/June 2015

Syllabus
9702

Paper
31

(iii) Gradient:
[1]
The hypotenuse of the triangle must be greater than half the length of the
drawn line.
The method of calculation must be correct.
Both read-offs must be accurate to half a small square in both the x and y directions.
y-intercept:
Either:
Correct read-offs from a point on the line and substituted into y = mx + c.
Read-off must be accurate to half a small square in both x and y directions.
Or:
Check read-off of the intercept directly from the graph
(accurate to half a small square).
(f) M = value of the candidate’s gradient and N = value of the candidate’s y-intercept.
Do not allow substitution methods. Do not allow fractions.
Unit for M correct (e.g. A–1 m–1 or A–1 cm–1 or A–1 mm–1 or mA–1 m–1 or mA–1 cm–1 or
mA–1 mm–1)
and unit for N correct (e.g. mA–1 or A–1).
2

(a) (i) Value of L with unit, in range 55.0 cm ≤ L ≤ 65.0 cm.

[1]

[1]

[1]
[1]

(ii) Value of m to nearest gram or better, in range 10.0 g ≤ m ≤ 100.0 g.

[1]

(iv) Correct justification of significant figures in p linked to significant figures in L and m.

[1]

(b) (i) Value of M to the nearest gram or better, in range 90.0 g ≤ M ≤ 110.0 g.
(iii) Correct calculation of C.
(c) (ii) Value of x to the nearest mm, with unit, in range 5.0 cm ≤ x ≤ 20.0 cm.
(iii) Absolute uncertainty in x in range 2 – 5 mm.
If repeated readings have been taken, then the uncertainty can be half the range
(but not zero) if the working is clearly shown.
Correct method of calculation to obtain percentage uncertainty.

[1]
[1]
[1]

[1]

(d) Second value of L.

[1]

Second value of x.

[1]

Correct trend for x with respect to L (x decreases as L decreases).

[1]

(e) (i) Two values of k calculated correctly.
(ii) Valid comment consistent with calculated values of k, testing against a criterion
specified by the candidate.

© Cambridge International Examinations 2015

[1]
[1]

www.dynamicpapers.com
Page 4

(f)

Mark Scheme
Cambridge International AS/A Level – May/June 2015

Syllabus
9702

Paper
31

(i) Limitations (4 max.)

(ii) Improvements (4 max.)

Do not credit

A

Two readings not enough to
draw a valid conclusion.

Take more readings (for
different L) and plot a graph/
take more readings and
compare k values.

“repeat readings”/
“too few readings”

B

Difficult to measure x with
reason, e.g. parallax/ruler not
in line with wood/strip moves
as touched while taking
measurement/mass obscures
end of rule/strip
oscillates/balance achieved for
a short time

Improved method to measure x
e.g. attach mass to bottom of
strip/mark scale on strip/mark
strip at balance point/measure
(L–x)/clamp ruler horizontally

Travelling microscope
Video

C

Difficult to balance with reason,
e.g. wind/air conditioning or
pivot moves

Method to remove wind, e.g.
turn off fans/close windows or
method of fixing pivot to bench
i.e. tape/heavier pivot

Sliding rule
Pivot size

D

Problem with Blu-Tack, e.g.
mass of Blu-Tack not taken
into account

Method to overcome problem
with Blu-Tack, e.g. measure
mass of Blu-Tack and add to
value of M or fix mass with
named adhesive, e.g.
tape/glue because this has
less mass

E

Difficult to know where centre
of mass is with reason, e.g.
slot in mass

Detailed method of finding
centre of mass

Mark centre of mass
Measure diameter

or
Difficult to place centre of mass Method to attach mass on strip
at end of strip
to ensure centre of mass is at
the end of strip, e.g. hang
mass from strip with thread
F

Two strips have different
density/p

Find mass or p of second strip

© Cambridge International Examinations 2015

Different thickness/crosssectional area

Advertisement