Physics (9702) · May/June 2012 · Mark scheme 32

Cambridge Physics (9702) mark scheme for paper 32, May/June 2012 — 9702/32/M/J/12, file 9702_s12_ms_32.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS
GCE Advanced Subsidiary Level and GCE Advanced Level

MARK SCHEME for the May/June 2012 question paper
for the guidance of teachers

9702 PHYSICS
9702/32

Paper 3 (Advanced Practical Skills 2),
maximum raw mark 40

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of
the examination. It shows the basis on which Examiners were instructed to award marks. It does not
indicate the details of the discussions that took place at an Examiners’ meeting before marking began,
which would have considered the acceptability of alternative answers.
Mark schemes must be read in conjunction with the question papers and the report on the
examination.

• Cambridge will not enter into discussions or correspondence in connection with these mark schemes.

Cambridge is publishing the mark schemes for the May/June 2012 question papers for most IGCSE,
GCE Advanced Level and Advanced Subsidiary Level syllabuses and some Ordinary Level
syllabuses.

www.dynamicpapers.com
Page 2
1

Mark Scheme: Teachers’ version
GCE AS/A LEVEL – May/June 2012

Syllabus
9702

Paper
32

(a) Value of L in range 0.80 m > L > 0.60 m. Consistent with unit.

[1]

(b) (iii) Value of h0, less than 50 cm, to the nearest mm.

[1]

(c) Six sets of readings of d and h scores 5 marks, five sets scores 4 marks etc.
Help from Supervisor –1.

[5]

Range of d:
To include 25.0 cm (0.250 m) or more and 10.0 cm (0.100 m) or less

[1]

Column headings:
Each column heading must contain a quantity and a unit
The unit must conform to accepted scientific convention e.g. d / m, d(m) or d in m,
(h – h0)/m, (L/2 – d)2/m2

[1]

Consistency:
All values of d and h must be given to the nearest mm.

[1]

Significant figures:
All values of (L/2 – d)2 to 2 or 3 s.f.

[1]

Calculation:
Values of (L/2 – d)2 calculated correctly.

[1]

(d) (i) Axes:
[1]
Sensible scales must be used, no awkward scales (e.g. 3:10).
Scales must be chosen so that the plotted points occupy at least half the graph grid in
both x and y directions.
Scales must be labelled with the quantity which is being plotted.
Scale markings must be no more than 3 large squares apart.
Plotting of points:
All observations in the table must be plotted.
Diameter of plots must be < half a small square (no blobs).
Plots must be accurate to half a small square.

[1]

Quality:
[1]
All points in the table must be plotted (at least 5) for this mark to be awarded. Scatter of
points must be less than 0.5 cm (0.005 m) of (h – h0) of a straight line.
(ii) Line of best fit:
[1]
Judge by balance of all points on the grid about the candidate’s line (at least 5 points).
There must be an even distribution of points either side of the line along the full length.
Allow one anomalous point only if clearly indicated by the candidate.
Line must not be kinked or thicker than half a small square.

© University of Cambridge International Examinations 2012

www.dynamicpapers.com
Page 3

Mark Scheme: Teachers’ version
GCE AS/A LEVEL – May/June 2012

Syllabus
9702

Paper
32

(iii) Gradient:
The hypotenuse of the triangle must be at least half the length of the drawn line.
Both read-offs must be accurate to half a small square in both x and y directions.
Do not allow ∆x / ∆y.
y-intercept:
Either:
Check correct read off from a point on the line and substituted into y = mx + c.
Read off must be accurate to half a small square in both x and y directions.
Or:
Check read-off of the intercept directly from the graph.
(e) Value of a = candidate’s gradient. Value of b = candidate’s intercept.
Unit for a (e.g. m) and b (e.g. m2) consistent with values.

[1]

[1]

[1]
[1]
[Total: 20]

2

(b) (i) Value of ball diameter or d to the nearest 0.1 mm (or 0.01 mm).
Values of ball diameter and d in range 5 mm < d < 25 mm.

[1]
[1]

(ii) Absolute uncertainty is between 2 mm and 5 mm.
[1]
If repeated readings have been taken, then the absolute uncertainty can be half the
range. Correct method shown to find the percentage uncertainty.
(iii) Correct calculation of A with consistent unit.
(c) (ii) Value of F, with unit.
Evidence of repeat measurements of F here or in (d)(ii).

[1]
[1]
[1]

(d) (ii) Second value of d.
[1]
Second value of A is given to the same number of s.f. (or one more s.f.) than d2.
[1]
Second value of F.
[1]
Quality: When d increases (second d value is larger than first d value) F also increases
(second F value is larger than first F value) and vice versa.
[1]
(e) (i) Two values of k calculated correctly.

[1]

(ii) Sensible comment relating to the calculated values of k, testing against a criterion
specified by the candidate.
[1]

© University of Cambridge International Examinations 2012

www.dynamicpapers.com
Page 4

Mark Scheme: Teachers’ version
GCE AS/A LEVEL – May/June 2012

Syllabus
9702

Paper
32

(f)
(i) Limitations 4 max.

(ii) Improvements 4 max.

No credit/not enough

A

two results not enough

take more readings and plot a
graph/
calculate more k values and
compare

‘repeat readings’ on its own/
few readings/
take more readings and
(calculate) average k/
only one reading

B

difficult to form a perfect
sphere or disc/diameter of
sphere or disc varied

method to make uniform
spheres/discs e.g. moulds

pre-sized spheres/
repeat diameter
measurement and average

C

reason for difficulty in
measuring d e.g. viewed
through ruler/parallax error in
d

method to improve
measurement of d e.g.
travelling microscope

eyes in line

D

difficult to pull newton-meter
parallel to ruler/bench

method to ensure force is
parallel to ruler e.g. use a
long string/pulley and
weights*

E

difficult to judge reading on
newton-meter when detaches
with reason e.g. ruler moves
suddenly/without warning (so
difficult to read newton-meter
at the instant the ruler starts
to move)/force drops to zero
immediately after detachment

method to read force at
detachment e.g. newton
meter with a ‘max hold’
facility/video and playback or
freeze frame/ use system of
pulley and weights or sand to
measure F*/ use force sensor
and datalogger or computer*

video to take reading/
digital (electronic) newton
meter/
parallax related to newton
meter/
difficult to measure force/
issue of viewing ruler and
meter simultaneously

F

contact area less than
calculated disc area/bulging
disc

G

difficult to zero newton-meter
when used horizontally

improved method to measure
F: e.g. use system of pulley
and weights or sand*/use
force sensor with datalogger
or computer*

zero error in newton-meter/
just a pulley

Do not allow: reaction time/human error/using vernier caliper/helpers/use of micrometer
screw gauge/effect of temperature/change in stickiness of Blu-Tack.
*This answer can be credited as D, E or G (but not more than once).
[Total: 20]

© University of Cambridge International Examinations 2012