Physics (9702) · May/June 2012 · Mark scheme 31

Cambridge Physics (9702) mark scheme for paper 31, May/June 2012 — 9702/31/M/J/12, file 9702_s12_ms_31.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS
GCE Advanced Subsidiary Level and GCE Advanced Level

MARK SCHEME for the May/June 2012 question paper
for the guidance of teachers

9702 PHYSICS
9702/31

Paper 3 (Advanced Practical Skills 1),
maximum raw mark 40

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of
the examination. It shows the basis on which Examiners were instructed to award marks. It does not
indicate the details of the discussions that took place at an Examiners’ meeting before marking began,
which would have considered the acceptability of alternative answers.
Mark schemes must be read in conjunction with the question papers and the report on the
examination.

• Cambridge will not enter into discussions or correspondence in connection with these mark schemes.

Cambridge is publishing the mark schemes for the May/June 2012 question papers for most IGCSE,
GCE Advanced Level and Advanced Subsidiary Level syllabuses and some Ordinary Level
syllabuses.

www.dynamicpapers.com
Page 2
1

Mark Scheme: Teachers’ version
GCE AS/A LEVEL – May/June 2012

Syllabus
9702

Paper
31

(a) (iii) Value of x in the range 0.50 – 0.60 m.

[1]

(b) (ii) Value of T with unit: 0.9 s < T < 1.3 s.
Evidence of repeats.

[1]
[1]

(c) Six sets of readings of x and T scores 4 marks, five sets scores 3 marks etc.
Incorrect trend –1. Minor help from Supervisor –1; major help –2.

[4]

Range of x at least 25 cm.

[1]

Column headings:
Each column heading must contain a quantity and a unit where appropriate.
The unit must conform to accepted scientific convention e.g. x/m or x(m) or x in m.

[1]

Consistency of presentation of raw readings:
All values of x must be given to the nearest mm.

[1]

Significant figures:
Significant figures for √x should be the same as, or one more than, s.f. for x.

[1]

Calculation: √x calculated correctly.

[1]

(d) (i) Axes:
[1]
Sensible scales must be used. Awkward scales (e.g. 3:10) are not allowed.
Scales must be chosen so that the plotted points on the grid occupy at least half the
graph grid in both x and y directions.
Scales must be labelled with the quantity that is being plotted.
Scale markings should not be greater than three large squares apart.
Plotting of points:
All the observations in the table must be plotted.
Check the points are plotted correctly.
Work to an accuracy of half a small square.
Do not accept ‘blobs’ (points with diameter greater than half a small square).

[1]

Quality:
[1]
All points in the table must be plotted (at least 5) for this mark to be scored. Judge by
the scatter of all the points about a straight line. All points must be within 0.04 m½
(0.4 cm½) on the √x axis from a straight line.
(ii) Line of best fit:
[1]
Judge by the balance of all the points on the grid (at least 5) about the candidate’s line.
There must be an even distribution of points either side of the line along the full length.
Allow one anomalous point if clearly indicated (e.g. circled or labelled) by the candidate.
Line must not be kinked or thicker than half a small square.

© University of Cambridge International Examinations 2012

www.dynamicpapers.com
Page 3

Mark Scheme: Teachers’ version
GCE AS/A LEVEL – May/June 2012

Syllabus
9702

Paper
31

(iii) Gradient:
[1]
The hypotenuse of the triangle must be at least half the length of the drawn line.
Both read-offs must be accurate to half a small square in both the x and y directions.
Do not allow ∆x/∆y.
y-intercept:
[1]
Either:
Check correct read-off from a point on the line, and substitution into y = mx + c. Readoff must be accurate to half a small square in both the x and y directions. Allow ecf of
gradient value.
Or:
Check the read-off of the intercept directly from the graph.
(e) Value of P = candidate’s gradient and Q = value of candidate’s intercept. Do not allow
fractions.
[1]
Unit for P (s m–½ or s cm–½ or s mm–½) consistent with value, and Q (s).

[1]
[Total: 20]

2

(a) (iii) Value of F0 with unit.
Evidence of repeats.

[1]
[1]

(iv) Absolute uncertainty in F0 in range 0.4 – 1 N.
If repeated readings have been taken, then the uncertainty can be half the range.
Correct method of calculation of percentage uncertainty.

[1]

(v) Value of µ given to 2 or 3 s.f.

[1]

(b) (ii) Value of θ with unit to the nearest degree.

[1]

(iii) Correct calculation of (sin θ + µ cos θ).

[1]

(c) (ii) Value of F.

[1]

(d) Second value of θ.
Second value of θ < first value of θ.
Second value of F < first value of F.
Allow F2 > F1 if θ2 > θ1.

[1]
[1]
[1]

(e) (i) Correct calculation of two values of k.

[1]

(ii) Sensible comment relating to the calculated values of k, testing against a specified
criterion.
[1]

© University of Cambridge International Examinations 2012

www.dynamicpapers.com
Page 4

Mark Scheme: Teachers’ version
GCE AS/A LEVEL – May/June 2012

Syllabus
9702

Paper
31

(f)
(i) Limitations 4 max.

(ii) Improvements 4 max.

No credit/not enough

A

two readings are not enough
(to draw a conclusion)

take more readings and plot
a graph/
calculate more k values and
compare

few readings/
take more readings and
calculate average k/
only one reading

B

some parts of board rougher
than others/
surface of board is uneven/
board not flat

method to ensure same
section of board used in each
experiment (e.g. mark one
section)

board is rough/
there is friction between the
block and the board/
use a smoother surface/
references to oil/lubricants

C

large (percentage) uncertainty
in F

use larger/heavier masses

values of F very similar

D

difficulty in arranging newtonmeter parallel to board/pulling
in line with board

use (long) piece of string to
connect the newton-meter to
the block

newton-meter touching board
when attached

E

block moves suddenly/without
warning (so difficult to read
newton-meter at the instant
the block starts to move)

use system of pulley and
weights/ sand to measure F/
use a newton-meter with a
max hold facility/
use video and playback/
use force sensor and
datalogger/computer

value of F changes when
block moves
F

board tends to slip/
board not stable/
supporting block can topple

method described to secure
board/block/support e.g.
clamp the board, fix the
supporting block to the bench
with tape/blu-tack

G

cannot zero newton-meter
when used horizontally

use system of pulley and
weights/ sand to measure F/
use force sensor and
datalogger/computer

zero error in newton-meter

Ignore ‘parallax problems’, ‘use assistant’ or references to draughts, fans, a.c.
[Total: 20]

© University of Cambridge International Examinations 2012

Advertisement