Physics (9702) · Feb/March 2019 · Mark scheme 33
Cambridge Physics (9702) mark scheme for paper 33, Feb/March 2019 — 9702/33/F/M/19, file 9702_m19_ms_33.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge Assessment International Education
Cambridge International Advanced Subsidiary and Advanced Level
PHYSICS
9702/33
Paper 3 Advanced Practical Skills 1
March 2019
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge International will not enter into discussions about these mark schemes.
Cambridge International is publishing the mark schemes for the March 2019 series for most Cambridge
IGCSE™, Cambridge International A and AS Level components and some Cambridge O Level components.
This document consists of 7 printed pages.
© UCLES 2019
[Turn over
9702/33
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Generic Marking Principles
March 2019
www.dynamicpapers.com
These general marking principles must be applied by all examiners when marking candidate answers. They should be applied alongside the
specific content of the mark scheme or generic level descriptors for a question. Each question paper and mark scheme will also comply with these
marking principles.
GENERIC MARKING PRINCIPLE 1:
Marks must be awarded in line with:
•
•
•
the specific content of the mark scheme or the generic level descriptors for the question
the specific skills defined in the mark scheme or in the generic level descriptors for the question
the standard of response required by a candidate as exemplified by the standardisation scripts.
GENERIC MARKING PRINCIPLE 2:
Marks awarded are always whole marks (not half marks, or other fractions).
GENERIC MARKING PRINCIPLE 3:
Marks must be awarded positively:
•
•
•
•
•
marks are awarded for correct/valid answers, as defined in the mark scheme. However, credit is given for valid answers which go beyond the
scope of the syllabus and mark scheme, referring to your Team Leader as appropriate
marks are awarded when candidates clearly demonstrate what they know and can do
marks are not deducted for errors
marks are not deducted for omissions
answers should only be judged on the quality of spelling, punctuation and grammar when these features are specifically assessed by the
question as indicated by the mark scheme. The meaning, however, should be unambiguous.
GENERIC MARKING PRINCIPLE 4:
Rules must be applied consistently e.g. in situations where candidates have not followed instructions or in the application of generic level
descriptors.
© UCLES 2019
Page 2 of 7
9702/33
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
March 2019
www.dynamicpapers.com
GENERIC MARKING PRINCIPLE 5:
Marks should be awarded using the full range of marks defined in the mark scheme for the question (however; the use of the full mark range may
be limited according to the quality of the candidate responses seen).
GENERIC MARKING PRINCIPLE 6:
Marks awarded are based solely on the requirements as defined in the mark scheme. Marks should not be awarded with grade thresholds or
grade descriptors in mind.
© UCLES 2019
Page 3 of 7
9702/33
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
March 2019
www.dynamicpapers.com
Answer
Marks
1(a)
value of x to nearest mm and in range 4.5 to 5.5 cm
1
1(b)
value of T in range 1.50 s to 2.50 s
1
repeat readings – at least two values of at least 5T
1
six sets of readings of x and T with correct trend and without help from supervisor scores 4 marks, five sets scores 3 marks
etc.
4
range:
xmin ⩽ 2.5 cm and xmax ⩾ 13.5 cm
1
column headings:
each column heading must contain a quantity and a unit
1
1(c)
the presentation of quantity and unit must conform to accepted scientific convention. e.g. T 2 / s2
© UCLES 2019
consistency:
all values of raw times must be given to the nearest 0.1 s or all values to the nearest 0.01 s
1
significant figures:
significant figures for every value of 1 / x same as, or one greater than, the s.f. of x as recorded in table
1
calculation:
values of 1 / x calculated correctly
1
Page 4 of 7
9702/33
Question
1(d)(i)
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
March 2019
www.dynamicpapers.com
Answer
Marks
axes:
sensible scales must be used, no awkward scales (e.g. 3:10)
scales must be chosen so that the plotted points occupy at least half the graph grid in both x and y directions
scales must be labelled with the quantity which is being plotted
scale markings should be no more than 3 large squares apart
1
plotting of points:
all observations must be plotted on the grid
diameter of plotted points must be ⩽ half a small square (no blobs)
plots must be accurate to within half a small square in both x and y directions
1
quality:
all points in the table must be plotted (at least 5) for this mark to be awarded. Scatter of plots must be no more than
± 0.05 cm–1 from a straight line in the 1 / x direction
1
1(d)(ii)
line of best fit:
judged by balance of all points on the grid (at least 5) about the candidate’s line. There must be an even distribution of points
either side of the line along the full length
one anomalous point is allowed only if clearly indicated (i.e. circled or labelled) by the candidate
lines must not be kinked or thicker than half a small square
1
1(d)(iii)
gradient:
the hypotenuse of the triangle used must be greater than half the length of the drawn line
method of calculation must be correct
both read-offs must be accurate to half a small square in both the x and y directions
1
y-intercept:
Either
correct read-off from a point on the line substituted into y = mx + c or an equivalent expression, with read-off accurate to half a s
square in both x and y directions
1
Or
intercept read directly from the graph, with read-off at x = zero accurate to half a small square in y direction
© UCLES 2019
Page 5 of 7
9702/33
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(e)
March 2019
www.dynamicpapers.com
Answer
Marks
a equal to candidate’s gradient, and b equal to candidate’s intercept, and values are not written as fractions
1
unit for a is correct and consistent with value
unit for b is correct
1
Question
Answer
Marks
2(a)
value for B, with unit
1
2(b)
measured value(s) for d, with unit, to nearest mm
1
evidence of repeat readings
1
2(c)
absolute uncertainty in d value ⩾ 0.2 cm and correct method of calculation to obtain percentage uncertainty.
if several readings have been taken, then the absolute uncertainty can be half the range if the working is clearly shown (but
not zero if values are equal)
1
2(d)
calculation of P correct
1
POT of P value matches unit
1
2(e)
justification based on s.f. in d, m and g
1
2(f)
value for second B
1
value for second d
1
Quality:
d smaller for smaller B
1
2(g)(i)
two values of k calculated correctly
1
2(g)(ii)
sensible comment relating to the calculated values of k, testing against a criterion specified by the candidate
1
© UCLES 2019
Page 6 of 7
9702/33
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
2(h)(i)
March 2019
www.dynamicpapers.com
Answer
two k values are not enough to draw a valid conclusion
Marks
4 max
difficult to measure B with reason, e.g. pressing on balloon / ruler scale doesn’t start at zero / parallax
difficult to balance Perspex block on balloon / balloon kept moving
difficult to measure d with reason, e.g. not circular / changes when block touched / parallax / refraction changes apparent size
difficult to see (edges of) contact patch (clearly)
2(h)(ii)
take more readings and plot a graph / calculate more k values and compare
workable method of reducing parallax for B e.g. callipers
fix balloon in place with tape / glue / Blu-tack / trap between blocks at sides
grid on block / travelling microscope / thinner block
use contrasting colours for balloon and liquid
© UCLES 2019
Page 7 of 7
4 max