Chemistry (9701) · Oct/Nov 2017 · Mark scheme 52
Cambridge Chemistry (9701) mark scheme for paper 52, Oct/Nov 2017 — 9701/52/O/N/17, file 9701_w17_ms_52.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge Assessment International Education
Cambridge International Advanced Subsidiary and Advanced Level
CHEMISTRY
9701/52
Paper 5 Planning, Analysis and Evaluation
October/November 2017
MARK SCHEME
Maximum Mark: 30
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge International will not enter into discussions about these mark schemes.
Cambridge International is publishing the mark schemes for the October/November 2017 series for most
®
Cambridge IGCSE , Cambridge International A and AS Level components and some Cambridge O Level
components.
® IGCSE is a registered trademark.
This document consists of 7 printed pages.
© UCLES 2017
[Turn over
9701/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
Answer
October/November
www.dynamicpapers.com
2017
Marks
1(a)(i)
CuCO3 and Cu(OH)2 both react (with HCl) or both form copper(II) chloride
1
1(a)(ii)
(Transfer) 12.5(0) cm3 of (10.0 mol dm–3) HCl using a (graduated) pipette or a burette
1
add to a 250 cm3 volumetric flask AND make to mark with distilled water
1
1(a)(iii)
Measure a volume of gas from the carbonate reaction
or
measure the (loss of) mass from the carbonate reaction
1
1(a)(iv)
Suitable apparatus for production of CO2
1
Suitable means of measuring CO2 evolved
1
Correct labels on axes
y-axis: volume (of gas) or mass loss or mass of ‘limewater’
and
x-axis: time or t
1
curved line (from origin) to reach a plateau, e.g.
1
1(a)(v)
© UCLES 2017
Page 2 of 7
9701/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(a)(vi)
Answer
Any sensible attempt seen to make the experiment accurate
If mass loss
Reduce risk of mass loss through spraying
Insert cotton wool plug
October/November
www.dynamicpapers.com
2017
Marks
1
If gas collection
Any method to reduce risk of gas loss
Check apparatus is sealed
Insert bung quickly
Any attempt to measure temperature
Check apparatus is at room temperature
Apparatus accuracy
Use an accurate or 2dp (or more) balance / gas syringe / measuring cylinder
1(a)(vii)
© UCLES 2017
mol of CuCO3 = 0.5 ÷ 123.5 = 4.05 × 10–3 mol
1
moles of HCl = 2 × 4.05 × 10–3 = 8.10 × 10–3 mol
and
volume of HCl = 8.10 × 10–3 ÷ 0.500 = 0.0162 dm3
= 16.2 cm3
1
Page 3 of 7
9701/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(b)
Answer
Any suitable precaution relating to stated hazard of given chemical
October/November
www.dynamicpapers.com
2017
Marks
1
For HCl
Precaution
(lab) gloves
Explanation
(10 mol dm–3) HCl is corrosive
For CuCO3
Precaution
(lab) gloves / wash hands (after use) / face or mouth mask
Explanation
Harmful if swallowed
1(c)(i)
moles of H2SO4 = 0.40 ×
1
24.15
= 9.66 × 10–3 mol
1000
mass of Cu3(CO3)2(OH)2 = 344.5 × 9.66 × 10–3 ÷ 3 = 1.11 g
% by mass =
© UCLES 2017
1
1
1.11
× 100% = 74.0%
1.50
Page 4 of 7
9701/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(c)(ii)
Answer
Problem 1
titres are not concordant / are too far apart / are 0.5(0) cm3 apart / difference is too large
Improvement
Repeat until (two) concordant titres have been achieved / two readings within 0.1(0) cm3
Problem 2
colour change (of indicator) will be masked
Improvement 2
Use an alternative indicator / named indicator
[1] for each problem, [1] for an improvement
© UCLES 2017
Page 5 of 7
October/November
www.dynamicpapers.com
2017
Marks
3
9701/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
2(a)(i)
Answer
D
)
m
Marks
3
Difference
in conc. D
D
m
24.04
120.20
2.08
–0.02
24.31
97.24
1.99
–0.16
24.40
81.33
1.91
–0.22
24.59
70.26
1.85
–0.39
24.67
61.68
1.79
–0.48
24.73
54.96
1.74
–0.57
24.77
49.54
1.69
–0.64
24.80
45.09
1.65
–0.70
24.83
41.38
1.62
–0.77
log(
October/November
www.dynamicpapers.com
2017
log[X]
D data correct [1]
log[X] data correct [1]
All data to 2 dp [1]
2(a)(ii)
2(b)
2(c)
© UCLES 2017
greater adsorption
1
greater surface area available
1
all nine points plotted correctly
1
best-fit straight line drawn
1
Correct point (at –0.22, 1.91) identified
1
Statement explaining lack of adsorption, e.g.
not enough stirring,
mass of activated charcoal too low,
surface area not high enough / too low / coagulation of charcoal / bulkier particles used
not left long enough
1
Page 6 of 7
9701/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
2(d)(i)
2(d)(ii)
© UCLES 2017
Answer
October/November
www.dynamicpapers.com
2017
Marks
co-ordinates read and recorded correctly
1
gradient determined and same value for b
1
intercept on y-axis read and recorded correctly
1
Page 7 of 7