Chemistry (9701) · May/June 2025 · Question paper 54
Cambridge Chemistry (9701) question paper for paper 54, May/June 2025 — 9701/54/M/J/25, file 9701_s25_qp_54.pdf.
Text of this paper
* 0000800000001 *
,
,
Cambridge International AS & A Level
¬Wz> 4mHuOªE]y6W
¬«y\u`p6|@\u
¥ue5eu UEE5¥5U
* 0 4 9 8 3 7 3 1 4 5 *
CHEMISTRY
9701/54
Paper 5 Planning, Analysis and Evaluation
May/June 2025
1 hour 15 minutes
You must answer on the question paper.
No additional materials are needed.
INSTRUCTIONS
●
Answer all questions.
●
Use a black or dark blue pen. You may use an HB pencil for any diagrams or graphs.
●
Write your name, centre number and candidate number in the boxes at the top of the page.
●
Write your answer to each question in the space provided.
●
Do not use an erasable pen or correction fluid.
●
Do not write on any bar codes.
●
You may use a calculator.
●
You should show all your working and use appropriate units.
INFORMATION
●
The total mark for this paper is 30.
●
The number of marks for each question or part question is shown in brackets [ ].
●
The Periodic Table is printed in the question paper.
●
Important values, constants and standards are printed in the question paper.
This document has 12 pages.
DC (SL/JG) 357426/3
© UCLES 2025
[Turn over
2
,
1
,
The relative molecular mass, Mr , of an unknown volatile liquid, Y, can be determined experimentally.
A student uses the following method to determine the volume of a conical flask.
step 1 Weigh a dry conical flask.
step 2 Fill the conical flask completely with distilled water.
DO NOT WRITE IN THIS MARGIN
* 0000800000002 *
step 4 Use a thermometer to measure the temperature of the distilled water in the conical flask.
The student collects the results shown in Table 1.1.
mass of dry flask / g
31.022
mass of flask filled with water / g
161.175
temperature of water in flask / °C
23.0
laboratory atmospheric pressure / kPa
99.0
DO NOT WRITE IN THIS MARGIN
Table 1.1
DO NOT WRITE IN THIS MARGIN
step 3 Weigh the conical flask when filled with distilled water.
(a) Fig. 1.1 shows the variation of the density of water with temperature.
1.000
0.999
density
/ g cm–3
0.997
0.996
0.995
16
18
20
22
24
temperature / °C
Fig. 1.1
© UCLES 2025
ĬÕú¾Ġ´íÈõÏĪÅĊàû¸þ×
ĬīěúÙīĪē×āöÙ͏ĤíĂ
ĥåµĕõõĥĕµÅąąÅõąõµÕ
9701/54/M/J/25
26
28
30
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
0.998
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
* 0000800000003 *
3
,
(i)
,
Use Fig. 1.1 to determine the density of water at 23.0 °C.
Give your answer to four decimal places.
density of water = g cm–3 [1]
(ii)
Calculate the volume of the flask, using the density of water determined in (a)(i).
volume of flask = cm3 [2]
(b) Another student determines the volume of a different conical flask to be 129.56 cm3. This
conical flask is used to determine the Mr of unknown volatile liquid Y.
The following method is used.
step 1 Cover the opening of the dry conical flask with aluminium foil and secure using a
rubber band.
step 2 Weigh the conical flask, aluminium foil and rubber band. Record the mass.
step 3 Use a syringe with a needle to make a small hole in the aluminium foil and inject
approximately 5 cm3 of Y into the conical flask. Remove the syringe.
step 4 Place the conical flask in a water-bath containing boiling water.
step 5 Allow all of Y to evaporate. Keep the conical flask containing vaporised Y in the boiling
water for a further 3 minutes.
step 6 Carefully remove the conical flask from the boiling water and dry the outside surface
thoroughly.
step 7 Weigh the conical flask, aluminium foil, rubber band and contents. Record this mass.
(i)
Suggest why the conical flask containing vaporised Y is kept in boiling water for 3 minutes
in step 5.
[1]
(ii)
Suggest why it is not necessary to determine the mass of liquid Y injected into the
conical flask by the syringe in step 3.
DO NOT WRITE IN THIS MARGIN
[1]
(iii)
The student thinks that Y is toxic. Other than wearing safety glasses and a lab coat, state
one safety precaution that must be taken when carrying out this experiment.
[1]
© UCLES 2025
Ĭ×ú¾Ġ´íÈõÏĪÅĊàù¸þ×
ĬīĜùÑĝĦģâ÷ċĐƾĤĤýĂ
ĥåÅÕµĕąõåµÕąÅĕĥµåÕ
9701/54/M/J/25
[Turn over
,
(c) Table 1.2 shows the student’s results.
Table 1.2
100.0
laboratory atmospheric pressure / kPa
99.0
mass of conical flask, aluminium foil and rubber band
measured in step 2 / g
31.123
mass of conical flask, aluminium foil, rubber band and
Y measured in step 7 / g
31.429
mass of Y in flask in step 7 / g
0.306
volume of conical flask used / cm3
129.56
Calculate the percentage error in the mass measured in step 2.
Show your working.
percentage error = [1]
(ii)
The student assumes that the vapour formed from liquid Y is an ideal gas. The ideal gas
equation is shown.
DO NOT WRITE IN THIS MARGIN
(i)
temperature of water-bath / °C
DO NOT WRITE IN THIS MARGIN
4
,
DO NOT WRITE IN THIS MARGIN
* 0000800000004 *
p = pressure of gas measured in Pa
V = volume of gas in m3
n = number of moles of gas
R = molar gas constant
T = temperature in K
Use the ideal gas equation and the results in Table 1.2 to calculate the amount, in mol, of
Y in the conical flask in step 7.
DO NOT WRITE IN THIS MARGIN
pV = nRT
© UCLES 2025
ĬÕú¾Ġ´íÈõÏĪÅĊÞû¸Ā×
ĬīĜüÑħĘĦÕùĄė¶ĢÂôõĂ
ĥĕĕÕõĕąÕÅĕåąąĕŵµÕ
amount of Y = mol [2]
9701/54/M/J/25
DO NOT WRITE IN THIS MARGIN
Assume that the temperature of the vapour formed from liquid Y is 100 °C.
DO NOT WRITE IN THIS MARGIN
* 0000800000005 *
5
,
(iii)
,
Calculate the Mr of Y.
DO NOT WRITE IN THIS MARGIN
Mr of Y = [1]
(d) The actual temperature of the vapour formed from liquid Y is less than 100 °C. Describe and
explain the effect this has on the calculated value of the Mr .
effect on calculated Mr
explanation
[1]
[1]
[Total: 12]
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
(e) The boiling point of methylbenzene is 111 °C.
Suggest why the Mr of methylbenzene cannot be determined using this method.
© UCLES 2025
Ĭ×ú¾Ġ´íÈõÏĪÅĊÞù¸Ā×
ĬīěûÙġĜĖäÿíÒĢĚĖôąĂ
ĥĕĥĕµõĥµÕĥõąąõåõåÕ
9701/54/M/J/25
[Turn over
2
,
A student carries out an experiment to determine the charge of an aqueous ion, Mn+(aq), of
metal M.
The student prepares 100.0 cm3 of 1.00 mol dm–3 aqueous copper(II) nitrate, Cu(NO3)2(aq), to
use in the experiment.
(a) Calculate the mass of Cu(NO3)2•3H2O(s) required to prepare 100.0 cm3 of 1.00 mol dm–3
Cu(NO3)2(aq).
mass = g [1]
DO NOT WRITE IN THIS MARGIN
6
,
DO NOT WRITE IN THIS MARGIN
* 0000800000006 *
Give the name and capacity of any apparatus used.
Write your answer using a series of numbered steps.
DO NOT WRITE IN THIS MARGIN
(b) Describe the steps the student should take to prepare 100.0 cm3 of 1.00 mol dm–3
Cu(NO3)2(aq) starting from the mass calculated in (a) supplied in a small beaker.
[3]
© UCLES 2025
ĬÙú¾Ġ´íÈõÏĪÅĊßùµþ×
ĬīĜûÖīôĐìČĀëĂĢ÷ÜõĂ
ĥÅÅĕµÕĥĕĕąÕąÅõąµõÕ
9701/54/M/J/25
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
* 0000800000007 *
7
,
,
(c) The student sets up the electrochemical cell shown in Fig. 2.1 to investigate the effect of
changing the concentration of Mn+(aq) on the measured cell potential, Ecell.
high-resistance voltmeter
V
A
Cu(s) electrode
DO NOT WRITE IN THIS MARGIN
M(s) electrode
1.00 mol dm–3
Cu(NO3)2(aq)
Fig. 2.1
Suggest the function of the item labelled A in Fig. 2.1.
[1]
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
Mn+(aq)
© UCLES 2025
ĬÛú¾Ġ´íÈõÏĪÅĊßûµþ×
ĬīěüÎĝðĠÍîñĞÖĚãÜąĂ
ĥŵÕõµąõąõąąÅĕĥõĥÕ
9701/54/M/J/25
[Turn over
8
,
(d) The student uses the apparatus in Fig. 2.1 to measure the cell potentials, using six solutions
each with a different concentration of Mn+(aq).
Table 2.1 shows the results obtained by the student.
Table 2.1
cell potential,
Ecell / V
log [Mn+]
1.00 × 10–2
3.295
–2.00
5.00 × 10–3
3.304
–2.30
1.00 × 10–3
3.325
–3.00
5.00 × 10–4
3.343
–3.30
1.00 × 10–4
3.354
–4.00
1.00 × 10–5
3.384
–5.00
electrode
potential of
Mn+(aq) / M(s)
/V
DO NOT WRITE IN THIS MARGIN
concentration
of Mn+(aq)
/ mol dm–3
electrode potential of Mn+(aq) / M(s) = ECu – Ecell
electrode potential of Cu2+(aq) / Cu(s), ECu = 0.337 V
Complete Table 2.1. Record your values to three decimal places.
[1]
(e) Identify the independent variable in this experiment.
DO NOT WRITE IN THIS MARGIN
,
DO NOT WRITE IN THIS MARGIN
* 0000800000008 *
© UCLES 2025
ĬÙú¾Ġ´íÈõÏĪÅĊÝùµĀ×
ĬīěùÎħþĩêôúĥø¶āÌíĂ
ĥõĥÕµµąÕĥÕõąąĕÅõõÕ
9701/54/M/J/25
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
[1]
DO NOT WRITE IN THIS MARGIN
* 0000800000009 *
9
,
(f)
(i)
,
Plot a graph on the grid in Fig. 2.2 to show the relationship between the electrode
potential of Mn+(aq) / M(s) and log [Mn+]. Use a cross (×) to plot each data point. Draw a
straight line of best fit.
–2.94
DO NOT WRITE IN THIS MARGIN
–2.96
–2.98
electrode potential of
Mn+(aq) / M(s) / V
–3.00
DO NOT WRITE IN THIS MARGIN
–3.02
–3.04
–3.06
–5
–4
–3
log
–2
[Mn+]
DO NOT WRITE IN THIS MARGIN
Fig. 2.2
(ii)
Circle the one point on the graph that you consider to be most anomalous.
Suggest one reason why this anomaly may have occurred during the experimental
procedure. Assume no error was made in the measurement of the cell potential.
[1]
(iii)
DO NOT WRITE IN THIS MARGIN
[2]
Suggest how the reliability of the data shown in Table 2.1 could be improved.
[1]
© UCLES 2025
ĬÛú¾Ġ´íÈõÏĪÅĊÝûµĀ×
ĬīĜúÖġĂęÏĆćää¾ÕÌýĂ
ĥõĕĕõÕĥµõååąąõåµĥÕ
9701/54/M/J/25
[Turn over
Use Fig. 2.2 to determine the gradient of the line of best fit.
State the coordinates of both points you used in your calculation. These must be selected
from your line of best fit. Give the gradient to three significant figures.
coordinates 1
coordinates 2
gradient = [2]
(ii)
For the electrode equilibrium,
Mn+(aq) + ne–,
M(s)
the Nernst equation can be written as shown.
E = Eo +
2.303 RT
log [Mn+]
nF
E = electrode potential
E o = standard electrode potential
R = molar gas constant
T = temperature in K
F = Faraday constant
The equation for a straight line is y = mx + c.
State which parts in the Nernst equation correspond to y, m and c.
y =
DO NOT WRITE IN THIS MARGIN
(g) (i)
,
DO NOT WRITE IN THIS MARGIN
10
,
DO NOT WRITE IN THIS MARGIN
* 0000800000010 *
(iii)
Use the value that you calculated for the gradient of your line of best fit in (g)(i) and the
Nernst equation to calculate the value of n in Mn+(aq).
The experiment is carried out at 25.0 °C.
(If you were unable to determine an answer to (g)(i), then use the value 0.0285 for the
gradient. This is not the correct value.)
n = [2]
[Total: 18]
© UCLES 2025
ĬÙú¾Ġ´íÈõÏĪÅĊàù·þ×
ĬīĚù×ĥĆïèûñ¿Ĝ¸ĥôąĂ
ĥåąĕµµåÕÅĥõÅąµÅõÅÕ
9701/54/M/J/25
DO NOT WRITE IN THIS MARGIN
c =
[3]
DO NOT WRITE IN THIS MARGIN
m =
11
,
,
Important values, constants and standards
molar gas constant
R = 8.31 J K–1 mol–1
Faraday constant
F = 9.65 × 104 C mol–1
Avogadro constant
L = 6.02 × 1023 mol–1
electronic charge
e = –1.60 × 10–19 C
molar volume of gas
Vm = 22.4 dm3 mol–1 at s.t.p. (101 kPa and 273 K)
Vm = 24.0 dm3 mol–1 at room conditions
ionic product of water
Kw = 1.00 × 10–14 mol2 dm–6 (at 298 K (25 °C))
specific heat capacity of water
c = 4.18 kJ kg–1 K–1 (4.18 J g–1 K–1)
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
DO NOT WRITE IN THIS MARGIN
* 0000800000011 *
© UCLES 2025
ĬÛú¾Ġ´íÈõÏĪÅĊàû·þ×
ĬīęúÏģĊÿÑýĀĊÀÀ±ôõĂ
ĥåõÕõÕŵÕĕåÅąÕåµÕÕ
9701/54/M/J/25
© UCLES 2025
ĬÙú¾Ġ´íÈõÏĪÅĊÞù·Ā×
ĬīęûÏĩüĊæăćāĞĤēĤýĂ
ĥĕåÕµÕÅĕµµÕÅÅÕąµÅÕ
91.2
88.9
57–71
Sr
strontium
87.6
Rb
rubidium
85.5
name
9
10
11
12
actinoids
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
93
Np
neptunium
–
92
U
uranium
238.0
91
Pa
protactinium
231.0
90
Th
thorium
232.0
89
Ac
actinium
–
–
plutonium
Pu
94
150.4
samarium
–
americium
Am
95
152.0
europium
–
curium
Cm
96
157.3
gadolinium
DO NOT WRITE IN THIS MARGIN
–
144.2
140.9
138.9
64
Gd
65
–
berkelium
Bk
97
158.9
terbium
Tb
66
67
–
einsteinium
Es
99
164.9
holmium
Ho
68
–
fermium
Fm
100
167.3
erbium
Er
69
–
mendelevium
Md
101
168.9
thulium
Tm
DO NOT WRITE IN THIS MARGIN
–
californium
Cf
98
162.5
dysprosium
Dy
–
moscovium
Lv
Ts
–
lawrencium
Lr
103
175.0
lutetium
Lu
71
–
tennessine
10
–
oganesson
Og
118
–
radon
Rn
86
131.3
xenon
Xe
54
83.8
krypton
Kr
36
39.9
argon
Ar
18
20.2
neon
Ne
DO NOT WRITE IN THIS MARGIN
–
nobelium
No
102
173.1
ytterbium
Yb
70
–
livermorium
117
–
astatine
At
85
126.9
iodine
I
53
79.9
bromine
Br
35
35.5
chlorine
Cl
17
19.0
fluorine
F
12
DO NOT WRITE IN THIS MARGIN
promethium
neodymium
praseodymium
cerium
140.1
lanthanum
Eu
63
62
61
Pm
60
Nd
59
Pr
58
Ce
57
La
Sm
–
–
–
–
–
–
–
–
–
–
–
–
–
lanthanoids
Fl
flerovium
Nh
nihonium
Cn
copernicium
Rg
roentgenium
Ds
darmstadtium
Mt
meitnerium
Hs
hassium
Bh
bohrium
Sg
seaborgium
Db
dubnium
Rf
rutherfordium
actinoids
Ra
radium
Fr
francium
Mc
116
115
114
113
112
111
110
109
108
107
106
105
104
89–103
–
88
polonium
lead
209.0
204.4
200.6
195.1
190.2
186.2
183.8
180.9
178.5
137.3
84
Po
83
127.6
tellurium
Te
52
79.0
selenium
Se
Bi
121.8
antimony
Sb
51
74.9
arsenic
As
bismuth
thallium
mercury
gold
197.0
platinum
iridium
192.2
osmium
rhenium
tungsten
tantalum
hafnium
barium
82
Pb
32.1
31.0
34
sulfur
phosphorus
33
S
207.2
81
Tl
80
Hg
79
Au
78
Pt
77
Ir
118.7
tin
Sn
50
72.6
germanium
Ge
32
16
16.0
14.0
P
oxygen
nitrogen
15
O
N
9
,
DO NOT WRITE IN THIS MARGIN
9701/54/M/J/25
lanthanoids
76
114.8
indium
In
49
69.7
gallium
Ga
31
Os
112.4
cadmium
Cd
48
65.4
zinc
Zn
30
75
107.9
silver
Ag
47
63.5
copper
Cu
29
Re
106.4
palladium
Pd
46
58.7
nickel
Ni
28
28.1
27.0
74
102.9
rhodium
Rh
45
58.9
cobalt
Co
27
silicon
aluminium
W
101.1
ruthenium
Ru
44
55.8
iron
Fe
26
8
73
–
technetium
Tc
43
54.9
manganese
Mn
25
7
Ta
95.9
molybdenum
Mo
42
52.0
chromium
Cr
24
6
14
Si
13
12.0
10.8
Al
carbon
boron
72
92.9
niobium
Nb
41
50.9
vanadium
V
23
5
relative atomic mass
C
B
8
7
4.0
6
5
helium
18
1.0
17
hydrogen
16
2
15
He
14
H
13
1
Group
Hf
87
zirconium
yttrium
38
37
132.9
Zr
Y
40.1
39.1
caesium
40
39
calcium
potassium
56
47.9
45.0
Ca
K
Ba
titanium
scandium
20
19
55
Ti
Sc
24.3
23.0
Cs
22
21
magnesium
sodium
4
3
12
9.0
6.9
Mg
beryllium
lithium
atomic number
Key
atomic symbol
11
Be
Li
Na
4
2
,
3
1
The Periodic Table of Elements
* 0000800000012 *