Chemistry (9701) · May/June 2017 · Mark scheme 32
Cambridge Chemistry (9701) mark scheme for paper 32, May/June 2017 — 9701/32/M/J/17, file 9701_s17_ms_32.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International Examinations
Cambridge International Advanced Subsidiary and Advanced Level
CHEMISTRY
9701/32
Paper 3 (Advanced Practical Skills 2)
May/June 2017
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2017 series for most Cambridge IGCSE®,
Cambridge International A and AS Level and Cambridge Pre-U components, and some Cambridge O Level
components.
® IGCSE is a registered trademark.
This document consists of 9 printed pages.
© UCLES 2017
[Turn over
9701/32
Question
1(a)
© UCLES 2017
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
May/June 2017
www.dynamicpapers.com
Answer
Marks
I Initial and final burette readings and volume added recorded for rough titre and accurate titre details tabulated.
[minimum 2 × 2 ‘boxes’ with relevant information]
1
II Initial and final burette readings recorded and volume of FB 2 added recorded for each accurate titration.
Headings and units correct for accurate titrations
Headings: initial / final (burette) reading / volume or reading / volume at start / finish
and
volume / FB 2 added/used or titre
and
Units: (cm3) or / cm3 or in cm3 [or cm3 by every entry]
1
III All accurate burette readings are recorded to the nearest 0.05 cm3
Do not award this mark if:
50(.00) is used as an initial burette reading;
more than one final burette reading is 50(.00);
any burette reading is greater than 50(.00)
1
IV The final accurate titre recorded is within 0.10 cm3 of any other accurate titre.
1
Page 2 of 9
9701/32
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(a)
1(b)
May/June 2017
www.dynamicpapers.com
Answer
Marks
For assessment of accuracy (Q) marks, each Examiner should round any accurate burette readings to the nearest
0.05 cm3, check subtractions and then select the “best” titres for supervisor and candidate using the hierarchy:
two identical; titres within 0.05 cm3; titres within 0.1 cm3; etc.
These best titres should be used to calculate the mean titre, expressed to the nearest 0.01 cm3.
The candidate’s titre is compared to the supervisor’s titre and δ calculated.
V, VI and VII
Award V, VI and VII for δ ⩽ 0.20 cm3
Award V and VI for 0.20 cm3 < δ ⩽ 0.30 cm3
Award V for 0.30 cm3 < δ ⩽ 0.50 cm3
3
Check mean titre is correctly calculated from clearly selected values (ticks or working).
• Candidate must average two (or more) titres where the total spread is ⩽ 0.20 cm3.
• Working must be shown or ticks must be put next to the two (or more) accurate readings selected.
• The mean should normally be quoted to 2 dp rounded to the nearest 0.01.
[e.g. 26.667 must be rounded to 26.67]
1
Two special cases where the mean may not be to 2 dp:
allow mean to 3 dp only for 0.025 or 0.075 e.g. 26.325;
allow mean to 1 dp if all accurate burette readings were given to 1 dp and the mean is exactly correct.
[e.g. 26.0 and 26.2 = 26.1 is correct
but 26.0 and 26.1 = 26.1 is incorrect.]
Do not award this mark if:
• the rough titre was used to calculate the mean;
• candidate carried out only 1 accurate titration;
• burette readings were incorrectly subtracted to obtain any of the accurate titre values;
• all burette readings (resulting in titre values used in calculation of mean) are integers.
Note: the candidate’s mean will sometimes be marked as correct even if it is different from the mean calculated by the
examiner for the purpose of assessing accuracy.
1(c)(i)
© UCLES 2017
Correctly calculates
1
0.100 x 25
= 2.5(0) × 10–3
1000
Page 3 of 9
9701/32
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(c)(ii)
May/June 2017
www.dynamicpapers.com
Answer
Correctly calculates
Marks
1
0.0025 x 1000
to 3 or 4 sf
(b )
1(c)(iii)
Correct expression 12.6 ÷ (ii)
1
1(c)(iv)
Anion in FB 1 = CHCl2COO– (allow ecf: for candidate’s answer to (iii))
CH3COO– : ⩽ 77
CH2ClCOO– : 77.5 – 111.5
CHCl2COO– : 112 – 146
CCl3COO– : ⩾ 146.5
1
1(d)(i)
Conc NaOH lower = > titre smaller = > smaller Mr
1
1(d)(ii)
No effect on identification unless closer to smaller mass acid
or (different Mr may lead to the) identification of a different acid with matching / close to Mr
1
Total:
Question
2(a)
2(b)(i)
© UCLES 2017
Answer
14
Marks
I Unambiguous headings and correct units tabulated for all 6 thermometer readings, mean temps, and ∆Ts
1
II All thermometer readings recorded to 0.5 °C and
∆Ts correctly calculated and
Mean temperatures correctly calculated to nearest .5 °C or to 1 or 2 dp
1
Award III if candidate ∆Ts within 1.5 °C
1
Award III and IV if candidate ∆Ts within 1.0 °C
1
Correctly calculates n acid = 0.05(0) mol
and
n NaOH = 0.045 mol
1
Page 4 of 9
9701/32
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
2(b)(ii)
2(b)(iii)
2(b)(iv)
+(v)
2(c)(i)
2(c)(ii)
May/June 2017
www.dynamicpapers.com
Answer
Marks
Correctly calculates
50 × 4.2 × ∆T1 to minimum 2 sf
Correct expression
1
(ii )
1
1000 x 0.045
2 × mol NaOH in (i) or 0.09(0) in (iv)
and
100 x 4.2 x ∆T ( 2 )
in (v)
Correctly uses
1000 x (iv )
1
Negative signs shown in (iii) and (v) and final answers to 2–4 sf in (ii), (iii) & (v)
1
% error in vol of FB 3 =
0.5 x 100
= 1.(0)%
50
1
% error in vol of FB 4 =
2 x 0.25 x 100
= 2.(0)%
25
1
Use a burette / pipette for volume measurements / instead of a measuring cylinder
or Add a lid to reduce heat loss (by convection) / to reduce convection
or Use thermometer reading to 0.2 °C / smaller divisions / calibrations / more sensitive
1
Total
© UCLES 2017
Page 5 of 9
12
9701/32
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
May/June 2017
www.dynamicpapers.com
Answer
Marks
FB 5 is CH3COOH; FB 6 is HCl; FB 7 is HNO3; FB 8 is CuSO4(aq); FB 9 is Na2edta
3(a)(i)
3(a)(ii)
© UCLES 2017
Selects Na2CO3 / Mg
1
Effervescence / bubbling / fizzing greater / faster with FB 6
1
FB 5 is the weak acid (ora) with some evidence
1
no reaction / no ppt / no change with Ag+
and
‘not needed’ with Ba2+ (do not allow ‘no change’ unless there is no evidence of ammonia in 2nd test)
Effervescence alone is not evidence so would expect ‘no change’.
1
Effervescence / gas / NH3 and turns (damp red) litmus blue
1
FB 7 is nitric acid from some evidence (can be effervescence in (ii))
1
Page 6 of 9
9701/32
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
3(b)
(i) – (vi)
Answer
May/June 2017
www.dynamicpapers.com
Marks
See below
6
Expected observations
test
observation
mark
(i) +
Na2CO3
(pale) blue ppt (Allow blue-green / green-blue / turquoise / cyan)
1
(ii) + KI
then
Yellow-brown / brown (not orange)
1
Na2S2O3
white / off-white ppt and soluble in excess
1
(iii) +
c.HCl and
(blue) (solution) turns green (shade greener)
(iv) + H2O
(green) (solution) turns (pale) blue (shade bluer)
1
(v) + NH3
(in excess) forming dark/deep blue solution
or solution much darker than (iv)
1
(vi) + edta
(solution) more blue / darker blue than (iv)
1
© UCLES 2017
Page 7 of 9
9701/32
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
Answer
May/June 2017
www.dynamicpapers.com
Marks
3(vii)
FB 8 contains Cu2+/copper(II)
1
3(viii)
Cu2+(aq) + CO32–(aq) → CuCO3(s)
Allow 2Cu2+(aq) + 4I–(aq) → 2CuI(s) + I2(aq or s)
Allow Cu2+(aq) + 2OH–(aq) → 2Cu(OH)2(s)
1
Total: 14
© UCLES 2017
Page 8 of 9
9701/32
May/June 2017
www.dynamicpapers.com
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Mark allocation
Skill
Manipulation, measurement and
observation (MMO)
Minimum Breakdown of marks
mark
allocation
12 marks
[17]
Presentation of data and
observations (PDO)
6 marks
[7]
Analysis, conclusions and
evaluation (ACE)
10 marks
[16]
Question
3
Total
mark
9
10
Statement Minimum
Marks
Successful collection of
data and observations
C
8
1
Quality of measurements
and observations
Q
2
3
Decisions relating to
measurements of
observations
De
2
1
Recording data or
observations
R
2
1
1
2
Display of calculation and
reasoning
Di
2
1
2
3
Data layout
L
2
1
1
2
Interpretation of data or
observations and
identifying sources of error
I
4
3
5
Drawing conclusions
Con
5
3
Suggesting improvements
Imp
1
Total
© UCLES 2017
Question Question
1
2
5
1
12
2
1
9
3
6
1
14
Page 9 of 9
2
1
14
40