Chemistry (9701) · May/June 2017 · Mark scheme 31
Cambridge Chemistry (9701) mark scheme for paper 31, May/June 2017 — 9701/31/M/J/17, file 9701_s17_ms_31.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International Examinations
Cambridge International Advanced Subsidiary and Advanced Level
CHEMISTRY
9701/31
Paper 3 Advanced Practical Skills 1
May/June 2017
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2017 series for most Cambridge IGCSE®,
Cambridge International A and AS Level and Cambridge Pre-U components, and some Cambridge O Level
components.
® IGCSE is a registered trademark.
This document consists of 8 printed pages.
© UCLES 2017
[Turn over
9701/31
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(a)
May/June 2017
www.dynamicpapers.com
Answer
Marks
I: All the following data is recorded
• rough titration: both burette readings and the titre
• initial and final burette readings for two (or more) accurate titrations
Headings and units are not required for this mark
1
II: Titre values recorded for accurate titrations, and
Appropriate headings and units in the accurate titration table
• initial / start (burette) reading / volume
• final / end (burette) reading / volume
• titre or volume used / added (not “difference”)
• unit: / cm3 or (cm3) or in cm3 (for each heading)
or cm3 unit given for each volume recorded
1
III: All accurate burette readings are recorded to the nearest 0.05 cm3.
1
The requirement to record to 0.05 applies to burette readings, including 0.00 cm3 (if this was the initial reading), but it does
not apply to the titre.
Do not award this mark if:
• 50(.00) is used as an initial burette reading
• more than one final burette reading is 50.(00)
• any burette reading is greater than 50.(00)
IV: Final uncorrected titre is within 0.10 cm3 of any previous uncorrected accurate titre.
© UCLES 2017
Page 2 of 8
1
9701/31
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
May/June 2017
www.dynamicpapers.com
Answer
Marks
Examiner rounds any accurate burette readings to the nearest 0.05 cm3, check subtractions and then select the “best” titres using the hierarchy:
• identical titres then
• accurate titres within 0.05 cm3, then
• accurate titres within 0.10 cm3, etc.
These best titres should be used to calculate the mean titre, expressed to nearest 0.01 cm3.
Examiner compares candidate’s tire value with that of the Supervisor.
1(b)
Award V, VI and VII if δ ⩽ 0.30 (cm3)
1
Award V and VI if 0.30 < δ ⩽ 0.50
1
Award V, only, if 0.50 < δ ⩽ 0.80
1
Candidate calculates the mean correctly.
1
•
•
•
•
© UCLES 2017
Candidate must take the average of two (or more) titres that are within a total spread of not more than 0.20 cm3.
Working / explanation must be shown or ticks must be put next to the two (or more) accurate readings selected.
The mean should be quoted to 2 dp, and be rounded to nearest 0.01 cm3.
(e.g. 26.667 cm3 must be rounded to 26.67 cm3)
Page 3 of 8
9701/31
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(b)
May/June 2017
www.dynamicpapers.com
Answer
Marks
Two special cases, where the mean need not be to 2 dp:
• Allow mean expressed to 3 dp only for 0.025 or 0.075 (e.g. 26.325 cm3)
• Allow mean if expressed to 1 dp, if all accurate burette readings were given to 1 dp and the mean is exactly
correct.
• (e.g. 26.0 and 26.2 = 26.1 is allowed)
• (e.g. 26.0 and 26.1 = 26.1 is wrong – should be 26.05)
Do not award this mark if:
• The rough titre was used to calculate the mean.
• The candidate did only one accurate titration.
• Burette readings were incorrectly subtracted to obtain any of the accurate titre values.
• All burette readings used to calculate the mean were recorded as integers
Note: the candidate’s mean will sometimes be marked correct even if it was different from the mean calculated by the
Examiner for the purpose of assessing accuracy.
No of moles of thiosulfate used = 0.110 × mean titre / 1000 (expressed to 3 or 4 sig fig)
1
Equation balanced I2 + 2Na2S2O3 → Na2S4O6 + 2NaI
and
no of moles of I2 = 0.5 × ans. in (i)
1
1(c)(iv)
Correct answer,
No of moles of copper(II) ions = 2 × answer (iii) (expressed to 3 or 4 sig fig)
1
1(c)(v)
Mr = 26.0 / ans (iv) × 25 / 1000
1
1(c)(i)
1(c)(ii) + (iii)
Total:
© UCLES 2017
Page 4 of 8
12
9701/31
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
2(a)
May/June 2017
www.dynamicpapers.com
Answer
Marks
I: Table of data, to include:
• Unit “covering” all weighings, or given for each weighing
• No repeat headings (i.e. not two lists of weighings)
• Appropriate headings for the three weighings:
Mass of crucible and lid
Mass of crucible, lid and FA 5 (or “contents before heating”)
Mass of crucible, lid and residue / CuO / contents after heating
1
II: Weighings recorded
• Six weighings recorded in the space provided.
• All weighings recorded to same number of decimal places (one or more)
• Label/heading to indicate which is Expt 1 and Expt 2
1
III: Both masses of FA 5 and residue, correctly subtracted
• Masses of FA 5 used recorded on page 4, correctly subtracted
• Masses of FA 5 used were between 2.5 – 3.0 g and 1.5 – 2.0 g
• Masses of residue recorded on page 4, correctly subtracted
1
For assessment of accuracy, examiner must check and correct (if necessary) the masses of FA 5 used and of CuO
obtained by the supervisor and by the candidate for Experiment 1.
• Examiner works out the ratio mass of FA5 / mass of CuO for the supervisor (2 dp)
• Examiner works out the ratio (mass FA 5: mass CuO) for the candidate (2 dp)
• Examiner calculates δ the difference between these two ratios.
2
Award IV and V if δ ⩽ 0.08
Award IV if 0.08 < δ ⩽ 0.15
1
VI: Observations made during heating
Solid goes black / black residue (formed)
or reference to blue/green flame
2(b)(i)
© UCLES 2017
•
•
No of moles CuO = mass of residue / 79.5
Answer must be correct and expressed to 3 or 4 sig fig
Page 5 of 8
1
9701/31
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
May/June 2017
www.dynamicpapers.com
Answer
•
•
2(b)(ii)
Marks
No of moles of FA 5 = answer (i) / 2
Mr = mass of FA 5 used / no of moles of FA 5
1
2(b)(iii)
Mr = mass of FA5 used in Expt 2 × 79.5 × 2/mass of residue (CuO)
1
2(b)(iv)
Mr of FA 5 calculated from Ar values = 239
1
2(b)(v)
Candidate should
• correctly calculate the 2.5% of Mr in (iv) = 5.98 / 6.0, and
• make a correct statement about the accuracy of the accepted formula, based on their result(s).
or correctly calculate % difference for their result(s) from Mr in (iv) and correct comment
1
2(c)(i)
2(c)(ii)
•
•
•
heat (crucible and residue) to constant mass
heat more gently for longer period
cool in a desiccator
1
•
•
to ensure that decomposition (of FA 5) is complete or to ensure that all the residue is CuO
to prevent escape of dust / smoke / solid (during heating)
1
Larger masses have lower percentage error in weighing
1
Total:
© UCLES 2017
Page 6 of 8
14
9701/31
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
Answer
May/June 2017
www.dynamicpapers.com
Marks
FA 6 is Cu(NO3)2; FA 7 is FeCl3
•
•
•
•
•
3(a)(i)
melts or dissolves or blue liquid / solution formed
condensation or steam / vapour produced
black residue / solid
brown gas / fumes
gas / oxygen relights a glowing spill
2
4 or 5 observations correct = 2 marks
2 or 3 observations correct = 1 mark
3(a)(ii)
FA 6 is Cu(NO3)2
3(b)(i)
1
•
•
with KI, FA 7 gives a brown / red-brown / red / orange solution
with starch, blue / blue-black / dark colour
1
•
•
•
with FA 6, blue precipitate (formed)
on heating, (blue precipitate) turns black
With FA 7, red-brown / brown / rust ppt. (formed )
1
•
•
With FA 6, no reaction / no change / no ppt.
With FA 7, white precipitate formed
1
•
•
•
With FA 6, (pale) blue precipitate, then
deep/dark blue (solution) with excess
With FA 7, red-brown / brown / rust precipitate (forms)
1
Mg test
Both observations correct
With FA 6, brown / black precipitate / solid formed or blue colour fades / disappears
With FA 7, fizzing / bubbling / effervescence
1
Test for hydrogen: (gas) “pops” with lighted splint
1
© UCLES 2017
Page 7 of 8
9701/31
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
May/June 2017
www.dynamicpapers.com
Answer
Marks
3(b)(ii)
FA 7 is acidic, because it fizzes / produces hydrogen with magnesium
1
3(b)(iii)
Fe3+(aq) + 3OH–(aq) → Fe(OH)3(s)
1
3(b)(iv)
Redox because iodine was produced (from iodide ions)
1
3(b)(v)
You can’t be certain about the colour of the precipitate (with AgNO3) due to the coloured solution / colour of FA 7.
or
You can’t be sure whether the precipitate with AgNO3 is white / AgCl or cream / AgBr
1
3(b)(vi)
Ammonia would react with the Fe3+ ions in FA 7 (masking the effect of ammonia on AgCl)
or
The cation in FA 7 gives a precipitate with ammonia (so the precipitate of AgCl would not appear to dissolve).
1
Total:
© UCLES 2017
Page 8 of 8
14