Chemistry (9701) · May/June 2016 · Mark scheme 52
Cambridge Chemistry (9701) mark scheme for paper 52, May/June 2016 — 9701/52/M/J/16, file 9701_s16_ms_52.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International Examinations
Cambridge International Advanced Subsidiary and Advanced Level
CHEMISTRY
9701/52
May/June 2016
Paper 5 Planning, Analysis and Evaluation
MARK SCHEME
Maximum Mark: 30
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2016 series for most Cambridge IGCSE®,
Cambridge International A and AS Level components and some Cambridge O Level components.
® IGCSE is the registered trademark of Cambridge International Examinations.
This document consists of 5 printed pages.
© UCLES 2016
[Turn over
www.dynamicpapers.com
Page 2
Mark Scheme
Cambridge International AS/A Level – May/June 2016
Question
1
Syllabus
9701
Paper
52
Expected answer
Mark
(a)
(As the E ocell value increases) ∆Hr decreases or ∆Hr becomes more negative or ∆Hr becomes more exothermic.
AND
The more reactive the metal then the greater the energy release will be.
OR
Energy output of both reactions is dependent upon the difference in reactivity (of metals).
[1]
(b)
Independent variable: The (type of) metal
Dependent variable: temperature change or rise or increase
OR
enthalpy change
[1]
Diagram should indicate a labelled insulated container
AND
a labelled thermometer in the liquid.
[1]
Mass of metal before and after
[1]
Initial temperature (before metal added)
AND
Highest temperature (after metal added)
[1]
(iii)
Wear gloves
[1]
(iv)
Moles CuSO4 = 0.025 mol, therefore moles of magnesium = 0.025 mol
[1]
(minimum) mass Mg > (0.025 × 24.3 =) 0.6075 g
AND
mass required value is greater than 0.6075 g
[1]
(v)
Larger surface area
AND
causes increased rate of reaction
[1]
(vi)
Ensure uniformity of heating (of solution)
[1]
(c) (i)
(ii)
© Cambridge International Examinations 2016
[1]
www.dynamicpapers.com
Page 3
Mark Scheme
Cambridge International AS/A Level – May/June 2016
Question
Expected answer
Syllabus
9701
Paper
52
Mark
50.0 × 4.18 × 58.5 = 12 226.5 (J)
[1]
∆Hr = 12 226.5 / 0.025 = 489 000 = – 489
1000
[1]
Complete circuit involving
labelled voltmeter;
labelled salt bridge;
two separate solutions;
[1]
(Solutions are) magnesium sulfate or MgSO4 with magnesium or Mg rod
and
copper(II) sulfate CuSO4 with copper or Cu rod
[1]
Concentration of solution(s) is 1 mol dm–3 or 1 M
[1]
(f)
So that values can be compared
[1]
(g)
Both ∆Hr (Zn) and ∆Hr (Fe) values which are consistent with the prediction in (a).
[1]
(d)
(e)
[18]
© Cambridge International Examinations 2016
www.dynamicpapers.com
Page 4
Mark Scheme
Cambridge International AS/A Level – May/June 2016
Question
2
Expected answer
Syllabus
9701
Paper
52
Mark
(a)
Mass of liquid Y
used / g
(b)
Volume of vapour
Y / cm3
0.15
48
0.10
35
0.21
72
0.17
58
0.24
83
0.09
31
0.20
70
0.23
79
0.12
41
0.22
73
All mass values.
[1]
All volume values.
[1]
Candidate’s points plotted correctly from table in 2(a).
[1]
Line of best fit drawn.
[1]
© Cambridge International Examinations 2016
www.dynamicpapers.com
Page 5
Mark Scheme
Cambridge International AS/A Level – May/June 2016
Question
(c) (i)
(ii)
(d) (i)
(ii)
(e)
Expected answer
Syllabus
9701
Paper
52
Mark
Y evaporates from the (hypodermic) syringe
OR
Y evaporates before injection
OR
Y evaporates before weighing / after injection
[1]
(Stop evaporation by)
Keeping the syringe as cool as possible
OR
Closing off the needle end to stop evaporation
OR
Minimising length of time between each weighing
[1]
correct co-ordinates.
[1]
correct calculation of the gradient
must be three significant figures
[1]
Calculation of Mr = 3.07×104 / gradient in 2(d)(i)
[1]
Answer
[1]
Mr (from mass spectrum) = 84
OR
empirical formula = CH2
OR
ratio of C and H seen as 1:2
[1]
Y is C6H12
[1]
[12]
© Cambridge International Examinations 2016