Chemistry (9701) · Feb/March 2026 · Question paper 52

Cambridge Chemistry (9701) question paper for paper 52, Feb/March 2026 — 9701/52/F/M/26, file 9701_m26_qp_52.pdf.

Advertisement
Loading the paper…
Text of this paper

Cambridge International AS & A Level

* 7 9 0 3 9 4 8 7 6 1 *

CHEMISTRY

9701/52

Paper 5 Planning, Analysis and Evaluation

February/March 2026
1 hour 15 minutes

You must answer on the question paper.
No additional materials are needed.
INSTRUCTIONS
●
Answer all questions.
●
Use a black or dark blue pen. You may use an HB pencil for any diagrams or graphs.
●
Write your name, centre number and candidate number in the boxes at the top of the page.
●
Write your answer to each question in the space provided.
●
Do not use an erasable pen. Do not use correction fluid or tape.
●
Do not write on any bar codes.
●
You may use a calculator.
●
You should show all your working and use appropriate units.

INFORMATION
●
The total mark for this paper is 30.
●
The number of marks for each question or part question is shown in brackets [ ].
●
The Periodic Table is printed in the question paper.
●
Important values, constants and standards are printed in the question paper.

This document has 12 pages.
DC (CJ) 354708/5
© Cambridge University Press & Assessment 2026

[Turn over

2
1

Solid X is a mixture of three salts, potassium chloride, KCl , sodium chloride, NaCl , and
sodium nitrate, NaNO3, only.
The mass of each substance in X is investigated by two experiments. In each experiment,
a different ion is precipitated out of an aqueous solution of X. The mass of each precipitate
is measured.
(a) A student weighs a sample bottle containing X and transfers X into a small beaker.
The student reweighs the sample bottle.
The measurements are shown in Table 1.1.
Table 1.1
mass of sample bottle and X / g

7.235

mass of sample bottle after transfer / g

6.035

mass of X transferred to small beaker / g
Complete Table 1.1 to determine the mass of X in the small beaker.
(b) (i)

[1]

Calculate the percentage error in the measurement of the mass of the sample bottle
and X shown in Table 1.1.
Show your working.

percentage error = % [1]
(ii)

Without changing any apparatus, suggest how the percentage error calculated in 1(b)(i)
can be reduced.

[1]

(c) Describe the steps the student should take to prepare 250.0 cm3 of an aqueous solution of
X, starting from the mass of X calculated in 1(a) supplied in the small beaker.
Give the name and capacity of any apparatus used.
Write your answer using a series of numbered steps.

[3]
© Cambridge University Press & Assessment 2026

9701/52/F/M/26

3
(d) Aqueous sodium tetraphenylborate, NaB(C6H5)4(aq), reacts with aqueous potassium ions to
form a precipitate.
The ionic equation for this reaction is shown.
B(C6H5)4–(aq) + K+(aq)

KB(C6H5)4(s)

KB(C6H5)4(s) is an irritant.
Figure 1.1 shows a Gooch crucible with a porous glass disc. The porous glass disc acts as a
fine filter to separate the precipitate from the aqueous reaction mixture.

porous
glass disc

Gooch crucible
Figure 1.1
The solution formed from solid X in 1(c) is labelled solution X.
In the first experiment, the student carries out the following steps.
step 1

Transfer 25.0 cm3 of solution X to a 250 cm3 conical flask labelled D.

step 2

Use a measuring cylinder to add approximately 40 cm3 of 0.0180 mol dm–3
NaB(C6H5)4(aq) to conical flask D. Stir slowly as the precipitate forms.
Leave conical flask D in an ice bath for 20 minutes.

step 3

Place a clean Gooch crucible in an oven at 120 °C.

step 4

After 20 minutes, remove the Gooch crucible from the oven, allow to cool and
record its mass.

step 5

Pour the mixture from conical flask D into the Gooch crucible and filter.

step 6

Wash the residue in the Gooch crucible.

step 7

Transfer the Gooch crucible and residue to the oven and leave for one hour
at 120 °C.

step 8

Remove the Gooch crucible from the oven and allow to cool. Record
the mass of the Gooch crucible and the residue.

© Cambridge University Press & Assessment 2026

9701/52/F/M/26

[Turn over

4
(i)

Other than wearing safety goggles, give one safety precaution that the student must
take when handling KB(C6H5)4(s).
[1]

(ii)

Identify a suitable piece of apparatus to transfer 25.0 cm3 of solution X in step 1.
[1]

(iii)

Suggest why the volume of NaB(C6H5)4(aq) does not need to be measured accurately
in step 2.
[1]

(iv)

Suggest one reason why conical flask D is kept cool in an ice bath in step 2.

[1]

(v)

Suggest one reason why the Gooch crucible is placed in an oven at 120 °C in step 3.

[1]

(vi)

The mass of residue is 0.3579 g.
Calculate the amount, in mol, of potassium ions, K+, in solid X in the small beaker
in 1(a).
[Mr: KB(C6H5)4, 357.9]

amount of K+ in solid X = mol [1]

© Cambridge University Press & Assessment 2026

9701/52/F/M/26

5
(vii)

Use your answer to 1(d)(vi) to determine the mass of KCl in solid X.

mass of KCl in solid X = g [1]
(e) Aqueous silver nitrate, AgNO3(aq), reacts with aqueous chloride ions, Cl –(aq), to form a
precipitate of silver chloride, AgCl (s).
The ionic equation for this reaction is shown.
Ag+(aq) + Cl – (aq)

AgCl (s)

In a second experiment, the student repeats steps 1 to 8 using aqueous silver nitrate,
AgNO3(aq), instead of NaB(C6H5)4(aq).
The mass of AgCl (s) recorded in step 8 is 0.2151 g.
The amount, n, in mol, of NaCl in solid X can be calculated using equation 1.
equation 1

n = Q – amount, in mol, of K+ in solid X in 1(d)(vi)

Q is the amount, in mol, of AgCl (s) produced when all the Cl –(aq) ions in 250 cm3 of
solution X react with AgNO3(aq).
(i)

Calculate Q.

Q = mol [1]
(ii)

Use equation 1 to calculate the mass, in g, of NaCl in solid X.
[If you were unable to obtain an answer to 1(e)(i), use Q = 0.014 mol. This is not the
correct answer.]

mass of NaCl in solid X = g [1]
(iii)

Calculate the mass of NaNO3 in solid X using your answers to 1(d)(vii), 1(e)(ii) and the
information given.

mass of NaNO3 in solid X = g [1]
© Cambridge University Press & Assessment 2026

9701/52/F/M/26

[Turn over

6
(f)

Complete Table 1.2 to show the effect, if any, on the calculated masses of KCl and NaCl if
the residue of KB(C6H5)4 was not washed in step 6 of the first experiment.
Use the words higher, lower or no effect in your answer.
Table 1.2
effect on calculated mass of KCl in 1(d)(vii)
effect on calculated mass of NaCl in 1(e)(ii)
[1]

(g) Another student repeated the first experiment but heated the Gooch crucible to 320 °C in
step 7.
Suggest why the mass of precipitate collected by this student was significantly lower than
the mass of precipitate collected by the first student.

[1]
[Total: 18]

© Cambridge University Press & Assessment 2026

9701/52/F/M/26

7

Turn over

© Cambridge University Press & Assessment 2026

9701/52/F/M/26

[Turn over

8
2

Blood plasma contains a number of different cations. Many of these cations emit a different
colour of light when placed in a flame.
Flame emission photometry is a method of determining the concentration of cations in a sample
using the intensity of light emitted.
In an experiment, a sample of blood plasma is placed into a colourless flame. K+ ions in the
blood plasma absorb energy from the flame and emit light with a lilac colour. The intensity of the
light emitted is measured.
To determine the concentration of K+ ions in the sample, a calibration graph showing the
relationship between known concentration of K+ ions and light intensity is required.
(a) A solution of potassium chloride, KCl (aq), is prepared.
The concentration of aqueous potassium ions, K+, in this solution is 0.100 g dm–3.
Different volumes of the solution of KCl (aq) are taken and diluted by adding specific
volumes of distilled water to prepare solutions of specific concentrations.
Each prepared solution of known [K+(aq)] is tested using flame emission photometry.
Table 2.1 shows the relative light intensity measured for each prepared solution.
Table 2.1
volume of
KCl (aq) / cm3

volume of distilled
water added / cm3

[K+(aq)]
/ g dm–3

relative
light intensity

0.00

50.00

0.00 × 10–3

0.0

0.50

1.00 × 10–3

2.1

1.00

2.00 × 10–3

4.2

1.50

3.00 × 10–3

6.7

2.00

4.00 × 10–3

8.8

2.50

5.00 × 10–3

11.0

3.00

6.00 × 10–3

11.2

3.50

7.00 × 10–3

15.7

4.00

8.00 × 10–3

17.1

4.50

9.00 × 10–3

17.1

5.00

10.00 × 10–3

17.1

(i)

Complete Table 2.1 to show the volume of distilled water added to make each prepared
[1]
solution of known [K+(aq)].

(ii)

Identify a suitable piece of apparatus for adding the distilled water.
[1]

(iii)

Identify the dependent variable in this experiment.
[1]

© Cambridge University Press & Assessment 2026

9701/52/F/M/26

9
(iv)

Plot a calibration graph on the grid in Figure 2.1 to show the relationship between
[K+(aq)] and relative light intensity.
Use a cross (×) to plot each data point.
Draw one line of best fit for [K+(aq)] from 0.00 × 10–3 to 7.00 × 10–3 g dm–3.
Draw a second line of best fit for [K+(aq)] from 8.00 × 10–3 to
10.00 × 10–3 g dm–3. Extend both lines so they meet.
18

16

14

12

10
relative
light intensity

8

6

4

2

0
0.00

2.00

4.00

6.00

8.00

10.00

12.00

[K+(aq)] / 10–3 g dm–3

© Cambridge University Press & Assessment 2026

Figure 2.1

[2]

9701/52/F/M/26

[Turn over

10
(v)

Describe how the graph shows that [K+(aq)] from 0.00 × 10–3 to 7.00 × 10–3 g dm–3 is
directly proportional to relative light intensity.
[1]

(vi)

Circle the most anomalous point on your graph in Figure 2.1. Suggest one reason to
explain the anomalous point you have circled.
[1]

(b) (i)

A sample of blood plasma is diluted 100 times and tested using flame emission
photometry. The relative light intensity recorded is 3.8.
Use your graph in Figure 2.1 to determine the [K+(aq)], in g dm–3, in the sample.
[K+(aq)] in diluted blood plasma = g dm–3 [1]

(ii)

The healthy range for [K+(aq)] in blood plasma is between 0.100 and 0.200 g dm–3.
State whether the sample of blood plasma tested in 2(b)(i) is within the healthy range,
too high or too low. Explain your answer.

[1]

(iii)

When testing samples of blood plasma, a coloured light filter needs to be used which
only allows lilac-coloured light emitted from the sample to reach the detector.
Suggest why this coloured light filter is needed when testing blood plasma but is not
necessary when testing KCl (aq).
[1]

(c) Explain why flame emission photometry is not suitable for measuring [K+(aq)] at
8.00 × 10–3 g dm–3 and above.

[1]
(d) State whether the data used for the calibration graph in Figure 2.1 is reliable.
Explain your answer.

[1]
[Total: 12]

© Cambridge University Press & Assessment 2026

9701/52/F/M/26

11
Important values, constants and standards
molar gas constant

R = 8.31 J K–1 mol–1

Faraday constant

F = 9.65 × 104 C mol–1

Avogadro constant

L = 6.022 × 1023 mol–1

electronic charge

e = –1.60 × 10–19 C

molar volume of gas

Vm = 22.4 dm3 mol–1 at s.t.p. (101 kPa and 273 K)
Vm = 24.0 dm3 mol–1 at room conditions

ionic product of water

Kw = 1.00 × 10–14 mol2 dm–6 (at 298 K (25 °C))

specific heat capacity of water

c = 4.18 kJ kg–1 K–1 (4.18 J g–1 K–1)

Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (Cambridge University Press & Assessment) to trace copyright holders, but if any items requiring clearance
have unwittingly been included, the publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in our Copyright
Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download at www.cambridgeinternational.org after the live
examination series.
Cambridge International Education is the name of our awarding body and a part of Cambridge University Press & Assessment, which is a department of the
University of Cambridge.

© Cambridge University Press & Assessment 2026

9701/52/F/M/26

© Cambridge University Press & Assessment 2026

scandium

39

calcium

38

potassium

37

9701/52/F/M/26

57–71

Fr

Ra

actinoids

–

radium

lanthanoids

–

francium

–

actinium

Ac

232.0

thorium

Th

140.1

90

138.9

89

Ce

58

–

cerium

La

Rf

rutherfordium

lanthanum

57

actinoids

104

89–103

178.5

88

137.3

87

132.9

hafnium

72

Hf

91.2

zirconium

Zr

40

47.9

titanium

Ti

barium

lanthanoids

88.9

56

Ba

87.6

yttrium

Y

45.0

strontium

Sr

40.1

Ca

22

4

Db

Pr

231.0

protactinium

Pa

91

140.9

praseodymium

59

–

dubnium

105

180.9

tantalum

73

Ta

92.9

niobium

Nb

41

50.9

vanadium

V

23

5

Cr

24

6

Sg

Nd

238.0

uranium

U

92

144.2

neodymium

60

–

seaborgium

106

183.8

tungsten

74

W

95.9

molybdenum

Mo

42

52.0

chromium

relative atomic mass

name

atomic number

Key

atomic symbol

caesium

Cs

55

85.5

rubidium

Rb

39.1

K

Sc

21

20

19

24.3

3

23.0

magnesium

Mg

12

9.0

beryllium

sodium

Na

11

6.9

lithium

Be

4

3

Li

2

1

Bh

Pm

–

neptunium

Np

93

–

promethium

61

–

bohrium

107

186.2

rhenium

75

Re

–

technetium

Tc

43

54.9

manganese

Mn

25

7

H

Hs

Sm

–

plutonium

Pu

94

150.4

samarium

62

–

hassium

108

190.2

osmium

76

Os

101.1

ruthenium

Ru

44

55.8

iron

Fe

26

8

1.0

hydrogen

1

Mt

Eu

–

americium

Am

95

152.0

europium

63

–

meitnerium

109

iridium

192.2

Ir

77

102.9

rhodium

Rh

45

58.9

cobalt

Co

27

9

Ni

28

10

Ds

Gd

–

curium

Cm

96

157.3

gadolinium

64

–

darmstadtium

110

195.1

platinum

78

Pt

106.4

palladium

Pd

46

58.7

nickel

Group

Rg

Tb

–

berkelium

Bk

97

158.9

terbium

65

–

roentgenium

111

197.0

gold

79

Au

107.9

silver

Ag

47

63.5

copper

Cu

29

11

The Periodic Table of Elements

Cn

Dy

–

californium

Cf

98

162.5

dysprosium

66

–

copernicium

112

200.6

mercury

80

Hg

112.4

cadmium

Cd

48

65.4

zinc

Zn

30

12

Nh

Ho

–

einsteinium

Es

99

164.9

holmium

67

–

nihonium

113

204.4

thallium

81

Tl

114.8

indium

In

49

69.7

gallium

Ga

31

27.0

aluminium

13

Al

10.8

boron

B

5

13

Fl

Er

–

fermium

Fm

100

167.3

erbium

68

–

flerovium

114

207.2

lead

82

Pb

118.7

tin

Sn

50

72.6

germanium

Ge

32

28.1

silicon

14

Si

12.0

carbon

C

6

14

Mc

Tm

–

mendelevium

Md

101

168.9

thulium

69

–

moscovium

115

209.0

bismuth

83

Bi

121.8

antimony

Sb

51

74.9

arsenic

As

33

31.0

phosphorus

P

15

14.0

nitrogen

N

7

15

Lv

Yb

–

nobelium

No

102

173.1

ytterbium

70

–

livermorium

116

–

polonium

84

Po

127.6

tellurium

Te

52

79.0

selenium

Se

34

32.1

sulfur

S

16

16.0

oxygen

O

8

16

Ts

Lu

Lr

–

lawrencium

103

175.0

lutetium

71

–

tennessine

117

–

astatine

85

At

iodine

126.9

I

53

79.9

bromine

Br

35

35.5

chlorine

17

Cl

19.0

fluorine

F

9

17

Og

–

oganesson

118

–

radon

86

Rn

131.3

xenon

54

Xe

83.8

krypton

36

Kr

39.9

argon

18

Ar

20.2

neon

10

Ne

4.0

helium

He

2

18

12

Advertisement