Biology (9700) · Oct/Nov 2024 · CI 35
Cambridge Biology (9700) ci for paper 35, Oct/Nov 2024 — 9700/35/O/N/24, file 9700_w24_ci_35.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International AS & A Level
BIOLOGY
9700/35
October/November 2024
Paper 3 Advanced Practical Skills 1
CONFIDENTIAL INSTRUCTIONS
* 7 4 7 6 1 5 4 4 1 7 *
This document gives details of how to prepare for and administer the practical exam.
The information in this document and the identity of any materials supplied by Cambridge International
are confidential and must NOT reach candidates either directly or indirectly.
The supervisor must complete the report at the end of this document and return it with the scripts.
INSTRUCTIONS
●
If you have any queries regarding these confidential instructions, contact Cambridge International
stating the centre number, the syllabus and component number and the nature of the query.
email
[email protected]
phone
+44 1223 553554
This document has 8 pages.
DC (WW) 336179/2
© UCLES 2024
[Turn over
www.dynamicpapers.com
2
General information about practical exams
Centres must follow the guidance on science practical exams given in the Cambridge Handbook.
Safety
Supervisors must follow national and local regulations relating to safety and first aid.
Only those procedures described in the question paper should be attempted.
Supervisors must inform candidates that materials and apparatus used in the exam should be treated
with caution. Suitable eye protection should be used where necessary.
The following hazard codes are used in these confidential instructions, where relevant:
C
HH
F
N
corrosive
health hazard
flammable
hazardous to the aquatic environment
MH
T
O
moderate hazard
acutely toxic
oxidising
Hazard data sheets relating to substances used in this exam should be available from your chemical
supplier.
Before the exam
●
●
●
The packets containing the question papers must not be opened before the exam.
It is assumed that standard school laboratory facilities, as indicated in the Guide to Planning
Practical Science, will be available.
Spare materials and apparatus for the tasks set must be available for candidates, if required.
During the exam
●
●
●
●
It must be made clear to candidates at the start of the exam that they may request spare materials
and apparatus for the tasks set.
Where specified, the supervisor must perform the experiments and record the results as instructed.
This must be done out of sight of the candidates, using the same materials and apparatus as the
candidates.
Any assistance provided to candidates must be recorded in the supervisor’s report.
If any materials or apparatus need to be replaced, for example, in the event of breakage or loss,
this must be recorded in the supervisor’s report.
After the exam
●
●
The supervisor must complete a report for each practical session held and each laboratory used.
Each packet of scripts returned to Cambridge International must contain the following items:
–
the scripts of the candidates specified on the bar code label provided
–
the supervisor’s results relevant to these candidates
–
the supervisor’s reports relevant to these candidates
–
seating plans for each practical session, referring to each candidate by candidate number
–
the attendance register.
© UCLES 2024
9700/35/CI/O/N/24
www.dynamicpapers.com
3
Specific information for this practical exam
During the exam, the supervisor or other competent biologist (not the invigilator) should obtain the
results needed for the supervisor’s report by following the relevant steps in the question paper. The
results should be recorded in the supervisor’s report.
Organisation of the exam
●
All candidates must have access to the materials required for Question 1 throughout the whole
period of the exam.
●
Half of the candidates will have access to the microscope and slide for a maximum time of one
hour from the start of the exam. These candidates should start with Question 2. After one hour, or
sooner if candidates have finished Question 2, they should move on to Question 1.
●
For Question 2, two candidates are not permitted to share the same microscope and slide at the
same time.
●
The other candidates should start with Question 1. After one hour, these candidates should be
given access to the microscope and slide. They should then move on to Question 2 as soon as
they are ready.
●
Candidates will only have access to the microscope and slide for one hour. They should be
advised that they can answer any part of the exam paper not requiring the microscope and slide
throughout the whole period of the exam.
●
Access arrangements to microscopes and slides, including instructions on which question to start
with and timings, must be explained to candidates before the start of the exam.
Materials to be supplied by Cambridge International
●
Slide M1
On receipt of the slides, check that they are labelled M1 and that no slides are broken. The slides
must not be viewed in advance of the exam. The material on the slides is confidential and must not be
disclosed to candidates.
The number of slides supplied by Cambridge International will be equal to half the candidate entry.
Return of slides to Cambridge International
Immediately after the exam, the slides must be:
●
returned to Cambridge International in the boxes in which they were received, using the
self-adhesive label supplied. The slides must not be included in the packet of scripts.
or
●
purchased using the order form enclosed with the slides, which should be completed and returned
to Cambridge International. The order form must not be included in the packet of scripts. Slides
and boxes will be charged at the rate of £3.25 per slide plus £1 per box.
If the slides are not returned or purchased by the deadline stated on the order form, the charge will be
£3.75 per slide plus £1 per box.
© UCLES 2024
9700/35/CI/O/N/24
[Turn over
www.dynamicpapers.com
4
Materials and apparatus for Question 1
Each candidate will need:
materials and apparatus for each candidate
quantity
[MH][N] Benedict’s solution (qualitative) in a beaker labelled B, provided at
room temperature
at least
30 cm3
[MH][N] 0.01 mol dm–3 iodine solution in a beaker labelled iodine, provided at
room temperature, with a teat pipette (see Preparation of materials)
at least
15 cm3
Solution of 0.5% starch and 1.0% glucose in a beaker labelled S1, provided at
room temperature (see Preparation of materials)
at least
20 cm3
10.0% glucose solution in a beaker labelled S2, provided at room temperature
(see Preparation of materials)
at least
20 cm3
1.0% starch solution in a beaker labelled S3, provided at room temperature (see
Preparation of materials)
at least
20 cm3
Solution of 0.5% starch and 3.0% glucose in a beaker labelled U, provided at
room temperature (see Preparation of materials)
at least
20 cm3
5 cm3 syringes
5
Beaker, capacity approximately 400 cm3, with tap water at room temperature,
labelled Water-bath
1
Test-tubes, small, capacity 20–30 cm3
8
Test-tube rack to hold 8 small test-tubes
1
Bunsen burner, tripod, gauze, bench mat and lighter or matches
1
Thermometer, – 10°C to + 110°C
1
Container, capacity approximately 200 cm3, with tap water, labelled For washing
1
Container, capacity approximately 200 cm3, labelled For waste
1
Paper towels
8
Marker pen, permanent
1
Stop-clock or timer showing seconds
1
Suitable eye protection
1
© UCLES 2024
9700/35/CI/O/N/24
3
www.dynamicpapers.com
5
Preparation of materials
Iodine solution (0.1 mol dm–3) should be prepared the day before the exam and kept in a
covered container in a refrigerator. 0.1 mol dm–3 iodine solution needs to be diluted to make the
0.01 mol dm–3 iodine solution no more than one hour before the start of the exam. This needs to be
at room temperature before the start of the exam.
S1, S2, S3 and U can be prepared the day before the exam. They should be kept in covered
containers in a refrigerator. Solutions should be at room temperature before the start of the exam.
●
iodine, 0.01 mol dm–3 iodine solution
Prepare a 0.1 mol dm–3 iodine solution the day before the exam:
–
put 8.0 g of potassium iodide in a beaker
–
add 2 cm3 of distilled water to moisten the potassium iodide
–
add 2.5 g of iodine [MH][N] (if necessary, crush to small pieces) to the moist potassium iodide
–
add 15 cm3 of distilled water and stir well.
When no more iodine dissolves:
–
add another 15 cm3 of distilled water and stir well
–
repeat with two more volumes of 15 cm3 of distilled water
–
make up to a total volume of 100 cm3.
It is not essential that all the iodine dissolves.
This forms a red-brown coloured, 0.1 mol dm–3 iodine solution.
On the day of the exam, dilute the 0.1 mol dm–3 iodine solution to make the 0.01 mol dm–3 iodine
solution:
–
put 10 cm3 of 0.1 mol dm–3 iodine solution into a beaker or container
–
make up to 100 cm3 with distilled water
–
mix well.
This forms a yellow-orange solution.
Prepare the 0.01 mol dm–3 iodine solution no more than one hour before the exam.
Keep the solution away from direct sunlight, for example in a brown glass bottle.
●
10.0% glucose solution
This is prepared by putting 10.0 g of glucose into 80 cm3 of warm distilled water. Make up to
100 cm3 with distilled water. Mix well.
●
6.0% glucose solution
This is prepared by putting 6.0 g of glucose into 80 cm3 of warm distilled water. Make up to 100 cm3
with distilled water. Mix well.
●
2.0% glucose solution
This is prepared by putting 2.0 g of glucose into 80 cm3 of warm distilled water. Make up to 100 cm3
with distilled water. Mix well.
© UCLES 2024
9700/35/CI/O/N/24
[Turn over
www.dynamicpapers.com
6
●
1.0% starch solution
This is prepared by putting 1.0 g of soluble starch into about 5 cm3 of warm distilled water in
a beaker. Mix to a paste. Make up to 100 cm3 with warm distilled water. Heat to boiling for 1 to
2 minutes, stirring well. Allow to cool.
●
S1, solution of 0.5% starch and 1.0% glucose
This is prepared by putting 10 cm3 of 1.0% starch solution into a beaker and putting 10 cm3 of
2.0% glucose solution into the same beaker. Mix well.
●
S2, 10.0% glucose solution
This is prepared by putting 20 cm3 of 10.0% glucose solution into a beaker.
●
S3, 1.0% starch
This is prepared by putting 20 cm3 of 1.0% starch solution into a beaker.
●
U, solution of 0.5% starch and 3.0% glucose
This is prepared by putting 10 cm3 of 1.0% starch solution into a beaker and putting 10 cm3 of
6.0% glucose solution into the same beaker. Mix well.
Materials and apparatus for Question 2
Each candidate will need:
materials and apparatus for each candidate
quantity
Microscope with:
● an eyepiece lens, ×10 magnification
● a low-power objective lens, ×10 magnification
● a high-power objective lens, ×40 magnification
1 between 2
Slide M1
1 between 2
3
Preparation of materials
●
Microscope
Any lenses which are not ×10 or ×40 should be removed or replaced.
For each candidate:
–
the microscope must be set up on low power
–
the slide must not be on the stage of the microscope.
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
Local Examinations Syndicate (UCLES), which is a department of the University of Cambridge.
© UCLES 2024
9700/35/CI/O/N/24
www.dynamicpapers.com
7
Supervisor’s report
Syllabus and component number
9
7
0
0
/
3
5
Centre number
Centre name
Time of the practical session
Laboratory name/number
Give details of any difficulties experienced by the centre or by candidates (include the relevant
candidate names and candidate numbers).
You must include:
● any difficulties experienced by the centre in the preparation of materials
● any difficulties experienced by candidates, e.g. due to faulty materials or apparatus
● any specific assistance given to candidates.
© UCLES 2024
9700/35/CI/O/N/24
[Turn over
www.dynamicpapers.com
8
Temperature of exam room °C
Results for Question 1(a)(iv)
Results for Question 1(a)(vii)
Declaration
1 Each packet that I am returning to Cambridge International contains all of the following items:
● the scripts of the candidates specified on the bar code label provided
● the supervisor’s results relevant to these candidates
● the supervisor’s reports relevant to these candidates
● seating plans for each practical session, referring to each candidate by candidate number
● the attendance register.
2 Where the practical exam has taken place in more than one practical session, I have clearly
labelled the supervisor’s results, supervisor’s reports and seating plans with the time and laboratory
name/number for each practical session.
3 I have included details of difficulties relating to each practical session experienced by the centre or
by candidates.
4 I have reported any other adverse circumstances affecting candidates, e.g. illness, bereavement or
temporary injury, directly to Cambridge International on a special consideration form.
Signed (supervisor)
Name (in block capitals)
© UCLES 2024
9700/35/CI/O/N/24