Biology (9700) · May/June 2023 · CI 31
Cambridge Biology (9700) ci for paper 31, May/June 2023 — 9700/31/M/J/23, file 9700_s23_ci_31.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International AS & A Level
BIOLOGY
9700/31
May/June 2023
Paper 3 Advanced Practical Skills 1
CONFIDENTIAL INSTRUCTIONS
* 6 6 2 6 6 4 6 7 6 0 *
This document gives details of how to prepare for and administer the practical exam.
The information in this document and the identity of any materials supplied by Cambridge International
are confidential and must NOT reach candidates either directly or indirectly.
The supervisor must complete the report at the end of this document and return it with the scripts.
INSTRUCTIONS
●
If you have any queries regarding these confidential instructions, contact Cambridge International
stating the centre number, the syllabus and component number and the nature of the query.
email
[email protected]
phone
+44 1223 553554
This document has 8 pages.
DC (PQ) 337209/3
© UCLES 2023
[Turn over
www.dynamicpapers.com
2
General information about practical exams
Centres must follow the guidance on science practical exams given in the Cambridge Handbook.
Safety
Supervisors must follow national and local regulations relating to safety and first aid.
Only those procedures described in the question paper should be attempted.
Supervisors must inform candidates that materials and apparatus used in the exam should be treated
with caution. Suitable eye protection should be used where necessary.
The following hazard codes are used in these confidential instructions, where relevant:
C
HH
F
N
corrosive
health hazard
flammable
hazardous to the aquatic environment
MH
T
O
moderate hazard
acutely toxic
oxidising
Hazard data sheets relating to substances used in this exam should be available from your chemical
supplier.
Before the exam
●
●
●
The packets containing the question papers must not be opened before the exam.
It is assumed that standard school laboratory facilities, as indicated in the Guide to Planning
Practical Science, will be available.
Spare materials and apparatus for the tasks set must be available for candidates, if required.
During the exam
●
●
●
●
It must be made clear to candidates at the start of the exam that they may request spare materials
and apparatus for the tasks set.
Where specified, the supervisor must perform the experiments and record the results as instructed.
This must be done out of sight of the candidates, using the same materials and apparatus as the
candidates.
Any assistance provided to candidates must be recorded in the supervisor’s report.
If any materials or apparatus need to be replaced, for example, in the event of breakage or loss,
this must be recorded in the supervisor’s report.
After the exam
●
●
The supervisor must complete a report for each practical session held and each laboratory used.
Each packet of scripts returned to Cambridge International must contain the following items:
–
the scripts of the candidates specified on the bar code label provided
–
the supervisor’s results relevant to these candidates
–
the supervisor’s reports relevant to these candidates
–
seating plans for each practical session, referring to each candidate by candidate number
–
the attendance register.
© UCLES 2023
9700/31/CI/M/J/23
3
www.dynamicpapers.com
Specific information for this practical exam
During the exam, the supervisor or other competent biologist (not the invigilator) should obtain the
results needed for the supervisor’s report by following the relevant steps in the question paper. The
results should be recorded in the supervisor’s report.
Organisation of the exam
●
All candidates must have access to the materials required for Question 1 throughout the whole
period of the exam.
●
Half of the candidates will have access to the microscope and slide for a maximum time of one
hour from the start of the exam. These candidates should start with Question 2. After one hour, or
sooner if candidates have finished Question 2, they should move on to Question 1.
●
For Question 2, two candidates are not permitted to share the same microscope and slide at the
same time.
●
The other candidates should start with Question 1. After one hour, these candidates should be
given access to the microscope and slide. They should then move on to Question 2 as soon as
they are ready.
●
Candidates will only have access to the microscope and slide for one hour. They should be
advised that they can answer any part of the exam paper not requiring the microscope and slide
throughout the whole period of the exam.
●
Access arrangements to microscopes and slides, including instructions on which question to start
with and timings, must be explained to candidates before the start of the exam.
Materials to be supplied by Cambridge International
●
Slide J1
On receipt of the slides, check that they are labelled J1 and that no slides are broken. The slides
must not be viewed in advance of the exam. The material on the slides is confidential and must
not be disclosed to candidates.
The number of slides supplied by Cambridge International will be equal to half the candidate entry.
Return of slides to Cambridge International
Immediately after the exam, the slides must be:
●
returned to Cambridge International in the boxes in which they were received, using the
self‑adhesive label supplied. The slides must not be included in the packet of scripts.
or
●
purchased using the order form enclosed with the slides, which should be completed and returned
to Cambridge International. The order form must not be included in the packet of scripts. Slides
and boxes will be charged at the rate of £3.25 per slide plus £1 per box.
If the slides are not returned or purchased by the deadline stated on the order form, the charge will be
£3.75 per slide plus £1 per box.
© UCLES 2023
9700/31/CI/M/J/23
[Turn over
4
www.dynamicpapers.com
Materials and apparatus for Question 1
Each candidate will need:
materials and apparatus for each candidate
quantity
7.0% yeast suspension, labelled Y, provided at room temperature
(see Preparation of materials)
at least
15 cm3
3.0% (10 vol) hydrogen peroxide solution in a beaker, labelled H, provided at
room temperature (see Preparation of materials)
at least
30 cm3
2.0% sodium alginate solution in a beaker, labelled S, provided at room
temperature (see Preparation of materials)
at least
30 cm3
1.5% calcium chloride solution in a beaker, labelled C, provided at room
temperature (see Preparation of materials)
at least
30 cm3
pH 3 buffer in a beaker, labelled B3, provided at room temperature
(see Preparation of materials)
at least
10 cm3
pH 4 buffer in a beaker, labelled B4, provided at room temperature
(see Preparation of materials)
at least
10 cm3
pH 6 buffer in a beaker, labelled B6, provided at room temperature
(see Preparation of materials)
at least
10 cm3
pH 7 buffer in a beaker, labelled B7, provided at room temperature
(see Preparation of materials)
at least
10 cm3
pH 8 buffer in a beaker, labelled B8, provided at room temperature
(see Preparation of materials)
at least
10 cm3
pH 6 buffer in a beaker, labelled U, provided at room temperature
(see Preparation of materials)
at least
10 cm3
10 cm3 syringe
1
5 cm3 syringes
4
Beaker, capacity 50–100 cm3
1
Test‑tubes, small, capacity 20–30 cm3
6
Test‑tube, large, capacity 40–50 cm3
1
Test‑tube rack to hold 6 small test‑tubes
1
Test‑tube rack to hold 1 large test‑tube
1
Petri dish, at least 1 cm depth
1
Blunt forceps
1
Container with approximately 200 cm3 tap water, labelled For washing
1
Container, capacity at least 400 cm3, labelled For waste
1
Paper towels
12
Glass marker pen (permanent)
1
Stop‑clock or timer showing seconds
1
Glass rod
1
Suitable eye protection
1
© UCLES 2023
9700/31/CI/M/J/23
✓
5
www.dynamicpapers.com
Preparation of materials
S, C, B3, B4, B6, B7, B8 and U may be prepared the day before the exam. They should be kept in a
covered container in a refrigerator overnight.
S, C, B3, B4, B6, B7, B8 and U should be at room temperature before the start of the exam.
●
Y, 7.0% yeast suspension
This is prepared by putting 7 g of yeast into a beaker and making up to 100 cm3 with distilled water.
Mix well.
●
H, 3.0% hydrogen peroxide
This is prepared by putting 50 cm3 of 6% (20 vol) hydrogen peroxide [MH] into a beaker and
making up to 100 cm3 with distilled water. Mix well.
●
S, 2.0% sodium alginate solution
This is prepared by sprinkling 2 g of sodium alginate into a beaker with 50 cm3 of warm distilled
water, stirring well and making up to 100 cm3 with warm distilled water. Continue stirring until
dissolved. You may need to heat gently to dissolve the sodium alginate.
Cool to room temperature.
●
C, 1.5% calcium chloride solution
This is prepared by putting 1.5 g of calcium chloride into a beaker with 80 cm3 of distilled water and
making up to 100 cm3 with distilled water. Mix well.
●
B3, B4, B6, U buffers at pH 3, pH 4 and pH 6
The buffers should be prepared using the following stock solutions:
1 dm3 of 0.1 mol dm–3 citric acid
This is prepared by putting 21.0 g of citric acid monohydrate (C6H8O7•H2O) [MH] in 500 cm3 of
distilled water and making up to 1 dm3 with distilled water. Mix well.
1 dm3 of 0.1 mol dm–3 tri-sodium citrate
This is prepared by putting 25.8 g of anhydrous tri‑sodium citrate in 500 cm3 of distilled water and
making up to 1 dm3 with distilled water. Mix well.
Then 100 cm3 of each buffer can be prepared as in the table:
●
buffer
pH
0.1 mol dm–3
citric acid
/ cm3
0.1 mol dm–3
tri-sodium citrate
/ cm3
distilled water
/ cm3
B3
3.0
46.4
3.6
50
B4
4.0
33.0
17.0
50
B6
6.0
10.0
40.0
50
U
6.0
10.0
40.0
50
B7, buffer at pH 7
This buffer should be prepared using the following stock solutions:
1 dm3 of 0.1 mol dm–3 sodium hydroxide
This is prepared by putting 4.0 g of sodium hydroxide [MH] in 500 cm3 of distilled water and making
up to 1 dm3 with distilled water. Mix well.
© UCLES 2023
9700/31/CI/M/J/23
[Turn over
www.dynamicpapers.com
6
1 dm3 of 0.1 mol dm–3 potassium dihydrogen (ortho) phosphate
This is prepared by putting 13.6 g of potassium dihydrogen phosphate [MH] in 500 cm3 of distilled
water and making up to 1 dm3 with distilled water. Mix well.
Then 100 cm3 of pH 7 buffer can be prepared as in the table:
●
buffer
pH
0.1 mol dm–3 NaOH
/ cm3
0.1 mol dm–3 potassium
dihydrogen phosphate
/ cm3
distilled water
/ cm3
B7
7.0
18.5
31.5
50
B8, buffer at pH 8
This buffer should be prepared using the following stock solutions:
1 dm3 of 0.1 mol dm–3 citric acid
As prepared for buffers B3, B4, B6 and U.
1 dm3 of 0.2 mol dm–3 disodium hydrogenphosphate
This is prepared by putting 53.6 g of disodium hydrogenphosphate(V)‑7‑water [MH] in 500 cm3 of
distilled water and making up to 1 dm3 with distilled water. Mix well.
Then 100 cm3 of the buffer can be prepared as in the table:
buffer
pH
0.2 mol dm–3 disodium
hydrogenphosphate
/ cm3
0.1 mol dm–3
citric acid
/ cm3
B8
8.0
97.3
2.7
Materials and apparatus for Question 2
Each candidate will need:
materials and apparatus for each candidate
quantity
Microscope with:
● an eyepiece lens, ×10 magnification
● a low‑power objective lens, ×10 magnification
● a high‑power objective lens, ×40 magnification
1 between 2
Slide J1
1 between 2
✓
Preparation of materials
●
Microscope
Any lenses which are not ×10 or ×40 should be removed or replaced.
For each candidate:
–
the microscope must be set up on low power
–
the slide must not be on the stage of the microscope.
Permission to reproduce items where third‑party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer‑related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
Local Examinations Syndicate (UCLES), which is a department of the University of Cambridge.
© UCLES 2023
9700/31/CI/M/J/23
www.dynamicpapers.com
7
Supervisor’s report
Syllabus and component number
9
7
0
0
/
3
1
Centre number
Centre name
Time of the practical session
Laboratory name/number
Give details of any difficulties experienced by the centre or by candidates (include the relevant
candidate names and candidate numbers).
You must include:
● any difficulties experienced by the centre in the preparation of materials
● any difficulties experienced by candidates, e.g. due to faulty materials or apparatus
● any specific assistance given to candidates.
© UCLES 2023
9700/31/CI/M/J/23
[Turn over
8
www.dynamicpapers.com
Temperature of exam room °C
Results for Question 1(a)(i).
Results for Question 1(a)(iv).
Declaration
1 Each packet that I am returning to Cambridge International contains all of the following items:
● the scripts of the candidates specified on the bar code label provided
● the supervisor’s results relevant to these candidates
● the supervisor’s reports relevant to these candidates
● seating plans for each practical session, referring to each candidate by candidate number
● the attendance register.
2 Where the practical exam has taken place in more than one practical session, I have clearly
labelled the supervisor’s results, supervisor’s reports and seating plans with the time and laboratory
name/number for each practical session.
3 I have included details of difficulties relating to each practical session experienced by the centre or
by candidates.
4 I have reported any other adverse circumstances affecting candidates, e.g. illness, bereavement or
temporary injury, directly to Cambridge International on a special consideration form.
Signed (supervisor)
Name (in block capitals)
© UCLES 2023
9700/31/CI/M/J/23