Biology (9700) · May/June 2021 · Question paper 34

Cambridge Biology (9700) question paper for paper 34, May/June 2021 — 9700/34/M/J/21, file 9700_s21_qp_34.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

Cambridge International AS & A Level

* 1 7 4 6 3 8 8 0 5 0 *

BIOLOGY

9700/34
May/June 2021

Paper 3 Advanced Practical Skills 2

2 hours
You must answer on the question paper.
You will need:

The materials and apparatus listed in the confidential instructions

INSTRUCTIONS
●
Answer all questions.
●
Use a black or dark blue pen. You may use an HB pencil for any diagrams or graphs.
●
Write your name, centre number and candidate number in the boxes at the top of the page.
●
Write your answer to each question in the space provided.
●
Do not use an erasable pen or correction fluid.
●
Do not write on any bar codes.
●
You may use a calculator.
●
You should show all your working and use appropriate units.

INFORMATION
●
The total mark for this paper is 40.
●
The number of marks for each question or part question is shown in brackets [ ].

For Examiner’s Use
1
2
Total

This document has 16 pages. Any blank pages are indicated.
DC (LK/CT) 195858/3
© UCLES 2021

[Turn over

2

www.dynamicpapers.com

Before you proceed, read carefully through the whole of Question 1 and Question 2.
Plan the use of the two hours to make sure that you finish the whole of Question 1 and Question 2.
1

Yeast cells contain the enzyme catalase which catalyses the breakdown of hydrogen peroxide,
releasing oxygen.
When a mixture of hydrogen peroxide and yeast cells is put into a syringe, some of the mixture
comes out of the syringe nozzle as the oxygen is released.
You are going to investigate the effect of pH on the activity of catalase.
You are provided with the materials shown in Table 1.1.
Table 1.1
labelled

contents

hazard

volume / cm3

H

3% hydrogen peroxide
solution

irritant

25

Y

yeast cell suspension

none

40

B3

buffer pH 3

none

10

B4

buffer pH 4

none

10

B5

buffer pH 5

none

10

B6

buffer pH 6

none

10

B7

buffer pH 7

none

10

U

unknown pH buffer

none

10

If any of the solutions come into contact with your skin, wash off immediately with cold water.
It is recommended that you wear suitable eye protection.
Wear gloves to protect your hands when using H.

© UCLES 2021

9700/34/M/J/21

www.dynamicpapers.com

3
Carry out step 1 to step 22.
1.

Put clear plastic tubing onto the nozzle of a 10 cm3 syringe, as shown in Fig. 1.1.

2.

Put two marks on the (plastic) tubing so that one mark is at a distance of 5 cm from the nozzle
and the other mark is at a distance of 15 cm from the nozzle, as shown in Fig. 1.1.
nozzle

clear plastic
tubing

10
9
8
7
6
5
4
3
2
1

syringe

5

15
ruler

Fig. 1.1
3.

Remove the tubing from the nozzle of the syringe.

4.

Use the glass rod to stir the yeast cell suspension, Y.

5.

Put the nozzle of the syringe into the beaker containing Y.

6.

Pull the plunger out to the 3 cm3 mark so that Y enters the syringe, as shown in Fig. 1.2.

10
9
8
7
6
5
4
3
2
1

Y

beaker
containing Y

Fig. 1.2

© UCLES 2021

9700/34/M/J/21

[Turn over

4

www.dynamicpapers.com

7.

Remove the syringe from the beaker containing Y and wipe the nozzle with a paper towel.

8.

Put the nozzle of the same syringe into the beaker containing the pH 3 buffer, B3.

9.

Pull the plunger out to the 5 cm3 mark so that approximately 2 cm3 of the buffer enters the
syringe, as shown in Fig. 1.3.

10
9
8
7
6
5
4
3
2
1

3 cm3 of Y
2 cm3 of pH
buffer

beaker
containing
pH buffer

Fig. 1.3
10. Remove the syringe from the beaker containing pH buffer and wipe the nozzle with a paper
towel.
11. Put the nozzle of the same syringe into the beaker containing hydrogen peroxide solution, H.
12. Pull the plunger out to the 6 cm3 mark so that approximately 1 cm3 of H enters the syringe, as
shown in Fig. 1.4.

© UCLES 2021

9700/34/M/J/21

www.dynamicpapers.com

5

10
9
8
7
6
5
4
3
2
1

mixture of Y and buffer

1 cm3 of H

beaker containing
hydrogen
peroxide solution, H

Fig. 1.4
13. Remove the syringe from the beaker containing hydrogen peroxide solution, H, and carefully
wipe the nozzle with a paper towel to remove excess H.
14. Put the tubing onto the nozzle.
15. Put the syringe and tubing on a flat surface, as shown in Fig. 1.5.
start timing when
mixture reaches
the 5 cm mark

stop timing when
mixture reaches
the 15 cm mark

10
9
8
7
6
5
4
3
2
1

mixture of Y,
buffer and H

5

15

mixture pushed out of
nozzle along tubing
Fig. 1.5
16. Start timing when the mixture reaches the mark at 5 cm.
17. Stop timing when the mixture reaches the mark at 15 cm. Record the time in (a)(i).
If the mixture does not reach the 5 cm mark or if it takes more than 4 minutes to reach the
15 cm mark, record as ‘more than 240’.
© UCLES 2021

9700/34/M/J/21

[Turn over

6

www.dynamicpapers.com

18. Hold the syringe with the nozzle up and remove the tubing from the syringe. Put the tubing
onto a paper towel.
19. Hold the syringe with the nozzle pointing downwards over the container labelled ‘For waste’
and empty the syringe.
20. Fill the syringe with water from the container labelled ‘For washing’. Put the tubing onto the
syringe nozzle and empty the syringe into the container labelled ‘For waste’.
21. Repeat step 3 to step 20 with each of the other pH buffers, B4, B5, B6 and B7.
(a) (i)

Record your results in an appropriate table.

[5]
(ii)

State the dependent variable for this investigation.
[1]

(iii)

Suggest an appropriate control for this investigation.

[1]

© UCLES 2021

9700/34/M/J/21

7

www.dynamicpapers.com

22. Repeat step 3 to step 20 with the unknown pH buffer, U. Record the time in (a)(iv).
(iv)

State the time for U.

Using your results from (a)(i) estimate the pH of U.
(v)

[2]

Identify one source of error in step 4 to step 17.
Suggest an improvement to the method which will reduce the effect of this error.
error

improvement

[2]

(vi)

The procedure described by step 1 to step 21 investigated the effect of pH on catalase
activity, by measuring the time taken for the mixture to move a set distance.
Describe how you would modify the procedure to investigate the effect of changing the
concentration of hydrogen peroxide on the time taken for the mixture to move a set
distance.

[2]

© UCLES 2021

9700/34/M/J/21

[Turn over

www.dynamicpapers.com

8

(b) A student investigated the effect of temperature on the activity of catalase, by measuring the
concentration of hydrogen peroxide remaining in the mixture after a set time.
The student used potassium manganate(VII) solution to determine the concentration of
hydrogen peroxide remaining in the mixture.
The greater the volume of potassium manganate(VII) used, the higher the concentration of
hydrogen peroxide remaining.
The results are shown in Table 1.2.
Table 1.2

© UCLES 2021

temperature
/ °C

volume of potassium
manganate(VII) used
/ cm3

10.0

11.0

23.0

7.0

32.0

4.5

38.5

3.2

49.0

7.4

58.5

10.8

9700/34/M/J/21

9
(i)

www.dynamicpapers.com

Plot a graph of the data in Table 1.2 on the grid in Fig. 1.6.
Use a sharp pencil for drawing graphs.

Fig. 1.6
(ii)

[4]

Use your graph to find the volume of potassium manganate(VII) needed when the
temperature was 45 °C.
volume of potassium manganate(VII) = cm3 [1]

© UCLES 2021

9700/34/M/J/21

[Turn over

10
(iii)

www.dynamicpapers.com

Suggest an explanation for the difference in concentration of hydrogen peroxide
remaining at 38.5 °C and at 58.5 °C.

[2]
[Total: 20]

© UCLES 2021

9700/34/M/J/21

11
2

www.dynamicpapers.com

M1 is a slide of a stained transverse section through a plant root.
(a) Set up the microscope so that you can observe the section on M1.
Use a sharp pencil for drawing.
(i)

Draw a large plan diagram of the whole section on M1. Your drawing should show the
correct shapes and proportions of the different tissues.
Use one ruled label line and label to identify the cortex.

[6]

© UCLES 2021

9700/34/M/J/21

[Turn over

12
(ii)

www.dynamicpapers.com

Observe the xylem vessel elements in the centre of the section of the root on M1.
Select one large xylem vessel element and three adjacent, touching, smaller cells.
Each smaller cell that you draw must touch the larger xylem vessel element and at least
one of the other smaller cells.

•

Make a large drawing of this group of four cells.

•

Use one ruled label line and label to identify a cell wall of one cell.

[5]

© UCLES 2021

9700/34/M/J/21

13

www.dynamicpapers.com

(b) Fig. 2.1 is a photomicrograph of a stained transverse section through a stem of a different
type of plant.

Fig. 2.1
(i)

Identify one similarity between the section on M1 and the section shown in Fig. 2.1.

[1]

(ii)

Identify the observable differences between the section on M1 and the section shown in
Fig. 2.1.
Record the observable differences in Table 2.1.
Table 2.1
feature

M1

Fig. 2.1

[3]
© UCLES 2021

9700/34/M/J/21

[Turn over

www.dynamicpapers.com

14

(c) Fig. 2.2 shows a diagram of a stage micrometer scale that is being used to calibrate an
eyepiece graticule.
The length of one division on this stage micrometer is 0.8 mm.

0

10

20

30

40

50

60

70

80

90

100

Fig. 2.2
(i)

Use Fig. 2.2 to calculate the actual length of one eyepiece graticule unit.
Show your working.

[3]

© UCLES 2021

9700/34/M/J/21

15

www.dynamicpapers.com

Fig. 2.3 shows a photomicrograph of a section of a stem, viewed using a microscope with an
eyepiece graticule.
0
10
20
30
40
50
60
70
80
90
100
Fig. 2.3
(ii)

The eyepiece graticule shown in Fig. 2.3 has been placed across the diameter of the
section.
Use the calibration of the eyepiece graticule unit from (c)(i) to calculate the actual
diameter of the section in Fig. 2.3.
Show your working.

[2]
[Total: 20]

© UCLES 2021

9700/34/M/J/21

16

www.dynamicpapers.com

BLANK PAGE

Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of the University of
Cambridge Local Examinations Syndicate (UCLES), which itself is a department of the University of Cambridge.

© UCLES 2021

9700/34/M/J/21

Advertisement