Biology (9700) · May/June 2021 · CI 33
Cambridge Biology (9700) ci for paper 33, May/June 2021 — 9700/33/M/J/21, file 9700_s21_ci_33.pdf.
Text of this paper
Cambridge International AS & A Level
BIOLOGY
9700/33
May/June 2021
Paper 3 Advanced Practical Skills 1
CONFIDENTIAL INSTRUCTIONS
* 3 1 9 6 9 6 7 7 0 7 *
This document gives details of how to prepare for and administer the practical exam.
The information in this document and the identity of any materials supplied by Cambridge
International are confidential and must NOT reach candidates either directly or indirectly.
The supervisor must complete the report at the end of this document and return it with the scripts.
INSTRUCTIONS
●
If you have any queries regarding these confidential instructions, contact Cambridge International
stating the centre number, the syllabus and component number and the nature of the query.
email [email protected]
phone +44 1223 553554
This document has 8 pages.
DC (NF) 195856/2
© UCLES 2021
[Turn over
2
General information about practical exams
Centres must follow the guidance on science practical exams given in the Cambridge Handbook.
Safety
Supervisors must follow national and local regulations relating to safety and first aid.
Only those procedures described in the question paper should be attempted.
Supervisors must inform candidates that materials and apparatus used in the exam should be treated
with caution. Suitable eye protection should be used where necessary.
The following hazard codes are used in these confidential instructions, where relevant:
C
HH
F
N
corrosive
health hazard
flammable
hazardous to the aquatic environment
MH
T
O
moderate hazard
acutely toxic
oxidising
Hazard data sheets relating to substances used in this exam should be available from your chemical
supplier.
Before the exam
●
●
●
The packets containing the question papers must not be opened before the exam.
It is assumed that standard school laboratory facilities, as indicated in the Guide to Planning
Practical Science, will be available.
Spare materials and apparatus for the tasks set must be available for candidates, if required.
During the exam
●
●
●
●
It must be made clear to candidates at the start of the exam that they may request spare materials
and apparatus for the tasks set.
Where specified, the supervisor must perform the experiments and record the results as instructed.
This must be done out of sight of the candidates, using the same materials and apparatus as the
candidates.
Any assistance provided to candidates must be recorded in the supervisor’s report.
If any materials or apparatus need to be replaced, for example, in the event of breakage or loss,
this must be recorded in the supervisor’s report.
After the exam
●
●
The supervisor must complete a report for each practical session held and each laboratory used.
Each packet of scripts returned to Cambridge International must contain the following items:
●
●
●
●
●
the scripts of the candidates specified on the bar code label provided
the supervisor’s results relevant to these candidates
the supervisor’s reports relevant to these candidates
seating plans for each practical session, referring to each candidate by candidate number
the attendance register.
© UCLES 2021
9700/33/CI/M/J/21
3
Specific information for this practical exam
During the exam, the supervisor or other competent biologist (not the invigilator) should obtain the
results specified on the supervisor’s report by following the relevant steps in the question paper. The
results should be recorded in the space provided on the supervisor’s report.
Organisation of the exam
●
Half the candidates should start on Question 1 and the other candidates should start on Question 2.
●
For Question 2, each candidate must have uninterrupted use of a microscope for at least
55 minutes.
Materials to be supplied by Cambridge International
●
Slide L1
On receipt of the slides, check that they are labelled L1 and that no slides are broken. The slides
should not be viewed in advance of the exam. The material on the slides is confidential and must
not be disclosed to candidates.
The number of slides supplied by Cambridge International will be equal to half the candidate entry.
Return of slides to Cambridge International
Immediately after the exam, the slides must be:
●
returned to Cambridge International in the boxes in which they were received, using the
self‑adhesive label supplied. The slides must not be included in the packet of scripts.
or
●
purchased using the order form enclosed with the slides, which should be completed and returned
to Cambridge International. The order form must not be included in the packet of scripts. Slides
and boxes will be charged at the rate of £3.25 per slide plus £1 per box.
If the slides are not returned or purchased by the deadline stated on the order form, the charge will be
£3.75 per slide plus £1 per box.
© UCLES 2021
9700/33/CI/M/J/21
[Turn over
4
Materials and apparatus for Question 1
Each candidate will need:
materials and apparatus for each candidate
quantity
[MH] 5.0% potassium hydroxide solution in a beaker, labelled P, provided at
room temperature (see Preparation of materials)
at least
10 cm3
0.15% copper sulfate solution in a beaker, labelled C, provided at room
temperature (see Preparation of materials)
at least
10 cm3
[MH] Benedict’s solution (qualitative) in a beaker, labelled B, provided at room
temperature
at least
20 cm3
[MH] Iodine solution in a beaker, labelled iodine, provided at room
temperature, with a teat pipette (see Preparation of materials)
at least
5 cm3
Distilled water, in a beaker, labelled S1, provided at room temperature
at least
10 cm3
10.0% glucose solution in a beaker, labelled S2, provided at room temperature
(see Preparation of materials)
at least
10 cm3
1.0% protein solution in a beaker, labelled S3, provided at room temperature
(see Preparation of materials)
at least
10 cm3
0.1% starch solution in a beaker, labelled S4, provided at room temperature
(see Preparation of materials)
at least
10 cm3
Starch and protein solution in a beaker, labelled U, provided at room
temperature (see Preparation of materials)
at least
10 cm3
Syringes, 2 cm3 or 3 cm3 or 5 cm3
5
Test‑tubes, small, capacity 20–30 cm3
7
Test‑tube rack to hold 7 test‑tubes
1
Bunsen burner, bench mat, gauze and tripod to support water‑bath
1
Beaker (capacity approximately 400 cm3), with approximately 200 cm3 water
at 40–50 °C, suitable for heating as a water‑bath and large enough to hold 3
test‑tubes, labelled water-bath.
1
Container with approximately 400 cm3 tap water, labelled For washing
1
Container, (capacity approximately 400 cm3), labelled For waste
1
Test‑tube holder
1
Thermometer, –10 °C to +110 °C
1
White card or white paper approximately 10 cm × 10 cm
1
Paper towels
8
Glass marker pen (permanent)
1
Suitable eye protection
1
© UCLES 2021
9700/33/CI/M/J/21
✓
5
It is advisable to wear suitable eye protection when handling chemicals.
Preparation of materials
P, C, S1, S4 and the stock solution of iodine may be prepared the day before the exam.
All solutions should be kept in a covered container in a refrigerator overnight and should be at room
temperature before the start of the exam.
[MH]
●
P, 5.0% potassium hydroxide solution
This is prepared by putting 5 g of potassium hydroxide [C][MH] in 80 cm3 of distilled
water in a beaker and making up to 100 cm3 with distilled water. Mix well.
●
C, 0.15% copper sulfate solution
This is prepared by putting 0.3 g of copper sulfate pentahydrate (CuSO4•5H2O)
[C][MH][N] in 80 cm3 of distilled water and making up to 100 cm3 with distilled water. Mix
well. This is the stock solution of 0.3%.
0.15% copper sulfate pentahydrate (CuSO4•5H2O), C, is prepared by putting 50 cm3 of
the stock solution into a beaker and making up to 100 cm3 with distilled water.
[MH]
●
iodine, 0.01 mol dm–3 iodine in potassium iodide solution
Stock solution of iodine: 0.1 mol dm–3
This is prepared by putting 8.0 g of potassium iodide in a beaker. Add 2 cm3 of distilled
water to moisten the potassium iodide. Add 2.5 g of iodine [MH][N] (if necessary, crush
to small pieces) to the moist potassium iodide, add 15 cm3 of distilled water and stir well.
When no more iodine dissolves, add another 15 cm3 of distilled water and stir well.
Repeat with two more volumes of 15 cm3 of distilled water and then make up to a total
volume of 100 cm3. It is not essential that all the iodine dissolves.
This gives a red‑brown coloured 0.1 mol dm–3 iodine solution.
Put 10 cm3 of 0.1 mol dm–3 iodine solution into a beaker and make up to 100 cm3 with
distilled water. Mix well. This makes the 0.01 mol dm–3 iodine solution and is a yellow‑
orange colour.
Keep the solution away from direct sunlight, for example in a brown glass bottle.
●
S2,10.0% glucose solution
This must be prepared on the day of the exam. This is prepared by putting 10 g of glucose
into 80 cm3 of warm distilled water. Make up to 100 cm3 with distilled water. Mix well.
Stock solution for protein solution: 2.0% albumen solution
This must be prepared on the day of the exam. This is prepared by putting 2 g of albumen
into a small volume of distilled water and mixing to make a paste. Make up to 100 cm3
with distilled water. Mix well.
●
S3, 1.0% protein solution
This is prepared by putting 50 cm3 of the 2.0% albumen stock solution in a beaker. Make
up to 100 cm3 with distilled water. Mix well.
© UCLES 2021
9700/33/CI/M/J/21
[Turn over
6
Stock solution for starch solution: 0.2% starch solution
This is used to make S4 and U. This is prepared by putting 0.2 g of starch into a small
volume of warm distilled water in a beaker. Mix to a paste. Make up to 100 cm3 with
warm distilled water. Heat to boiling for 1 to 2 minutes, stirring well. Allow to cool.
●
S4, 0.1% starch solution
This is prepared by putting 50 cm3 of the 0.2% starch stock solution in a beaker. Make up
to 100 cm3 with distilled water. Mix well.
●
U, starch and protein solution
This is prepared by putting 50 cm3 of the 2.0% albumen stock solution into a beaker and
putting 50 cm3 of the 0.2% starch solution into the same beaker. Mix well.
Materials and apparatus for Question 2
Each candidate will need:
materials and apparatus for each candidate
quantity
Microscope with:
● an eyepiece lens, ×10 magnification
● a low‑power objective lens, ×10 magnification
● a high‑power objective lens, ×40 magnification
1 between 2
Slide L1
1 between 2
✓
Preparation of materials
●
Microscope
Any lenses which are not ×10 or ×40 should be removed or replaced.
For each candidate:
● the microscope must be set up on low power
● the slide must not be on the stage of the microscope.
Permission to reproduce items where third‑party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer‑related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of the University of
Cambridge Local Examinations Syndicate (UCLES), which itself is a department of the University of Cambridge.
© UCLES 2021
9700/33/CI/M/J/21
7
Supervisor’s report
Syllabus and component number
9
7
0
0
/
3
3
Centre number
Centre name
Time of the practical session
Laboratory name/number
Give details of any difficulties experienced by the centre or by candidates (include the relevant
candidate names and candidate numbers).
You must include:
●
●
●
any difficulties experienced by the centre in the preparation of materials
any difficulties experienced by candidates, e.g. due to faulty materials or apparatus
any specific assistance given to candidates.
© UCLES 2021
9700/33/CI/M/J/21
[Turn over
8
Temperature of exam room °C
Results for Question 1(a)(iii)
Results for Question 1(a)(v)
Declaration
1 Each packet that I am returning to Cambridge International contains the following items:
the scripts of the candidates specified on the bar code label provided
the supervisor’s results relevant to these candidates
the supervisor’s reports relevant to these candidates
seating plans for each practical session, referring to each candidate by candidate number
the attendance register.
2 Where the practical exam has taken place in more than one session, I have clearly labelled
the supervisor’s results, supervisor’s reports and seating plans with the time and laboratory
name/number for each practical session.
3 I have included details of difficulties relating to each practical session experienced by the centre or
by candidates.
4 I have reported any other adverse circumstances affecting candidates, e.g. illness, bereavement or
temporary injury, directly to Cambridge International on a special consideration form.
Signed (supervisor)
Name (in block capitals)
© UCLES 2021
9700/33/CI/M/J/21