Biology (9700) · May/June 2018 · Question paper 31
Cambridge Biology (9700) question paper for paper 31, May/June 2018 — 9700/31/M/J/18, file 9700_s18_qp_31.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International Examinations
Cambridge International Advanced Subsidiary and Advanced Level
* 5 0 0 8 7 8 1 0 5 9 *
9700/31
BIOLOGY
May/June 2018
Paper 3 Advanced Practical Skills 1
2 hours
Candidates answer on the Question Paper.
Additional Materials:
As listed in the Confidential Instructions.
READ THESE INSTRUCTIONS FIRST
Write your Centre number, candidate number and name on all the work you hand in.
Write in dark blue or black pen.
You may use an HB pencil for any diagrams or graphs.
Do not use staples, paper clips, glue or correction fluid.
DO NOT WRITE IN ANY BARCODES.
Answer all questions.
Electronic calculators may be used.
You may lose marks if you do not show your working or if you do not use appropriate units.
At the end of the examination, fasten all your work securely together.
The number of marks is given in brackets [ ] at the end of each question or part question.
For Examiner’s Use
1
2
Total
This document consists of 14 printed pages and 2 blank pages.
DC (ST/SW) 137882/3
© UCLES 2018
[Turn over
www.dynamicpapers.com
2
Before you proceed, read carefully through the whole of Question 1 and Question 2.
Plan the use of the two hours to make sure that you finish all the work that you would like to do.
If you have enough time, think about how you can improve the confidence in your results, for
example by obtaining and recording one or more additional measurements.
You will gain marks for recording your results according to the instructions.
1
Milk contains proteins which are used to make cheese.
During cheese making, bacteria are added to the milk. The bacteria change the pH of the milk to
acidic, causing the proteins to coagulate (clot) forming curds. The curds are then used to make
the cheese.
proteins in milk coagulate
(curds)
milk + bacteria
pH more acidic
Estimating the protein concentration in milk is important when making cheese.
You will need to:
make simple (proportional) dilutions of the proteins in the milk, M
carry out the biuret test on each concentration, to provide a measure of the concentration of
proteins present in the milk
• carry out the biuret test on milk with an unknown concentration of protein, U
• estimate the concentration of milk protein in U.
•
•
You are provided with the materials shown in Table 1.1.
Table 1.1
labelled
contents
hazard
volume / cm3
M
1.0% milk
none
40
U
milk with an unknown
concentration of protein
none
20
K
5% potassium hydroxide
solution
harmful
irritant
20
C
0.15% copper sulfate solution
none
20
W
distilled water
none
100
It is recommended that you wear suitable eye protection.
If K comes into contact with your skin, wash it off immediately under cold water.
© UCLES 2018
9700/31/M/J/18
3
www.dynamicpapers.com
(a) You are required to make simple (proportional) dilutions of the proteins in the milk, M (1.0%).
Reduce the concentration by 0.2% between each successive dilution.
You will also make a 0.1% concentration.
You will need to prepare 10 cm3 of each concentration.
(i)
Table 1.2 shows how to make up two of the concentrations you will use, 1.0% and 0.1%.
Decide which other concentrations of milk to prepare using simple (proportional) dilutions
of M.
Complete Table 1.2 to show how you will prepare the other concentrations.
Table 1.2
volume of M
/ cm3
volume of
distilled water, W
/ cm3
percentage concentration
of milk
10.0
0.0
1.0
1.0
9.0
0.1
[2]
Read step 1 to step 9 before proceeding.
1.
Prepare all the concentrations of milk as shown in Table 1.2 in the test-tubes provided.
2.
Put the bung into one of the test-tubes and invert it to mix well. Repeat with each of the
test-tubes.
3.
Label the spotting tile with the concentrations of milk prepared in step 1.
4.
Use a pipette to put 2 drops of 1.0% milk into the labelled cavity on the tile.
Any milk remaining in the pipette should be put back into the test-tube so that as little of
the milk as possible is removed from the test-tube. You will need this milk for step 13.
5.
Repeat step 4 with each of the concentrations of milk.
6.
Put 1 or 2 drops of K into each of the concentrations of milk on the tile and mix.
7.
Put 0.5 cm3 of C into each mixture on the tile, using the syringe labelled C.
8.
Leave for 2 minutes for the colour to change.
© UCLES 2018
9700/31/M/J/18
[Turn over
4
9.
Compare the colour with the standard colours in Fig. 1.1. Record the colour of the mixture
in (a)(ii).
pale
violet
violet
www.dynamicpapers.com
blue
Fig. 1.1
(ii)
Record your results in an appropriate table for the known concentrations of milk, using
only the standard colours shown in Fig. 1.1.
[3]
You are now required to estimate the concentration of milk in sample U. This provides a
measure of the proteins in the milk.
10. Put 2 drops of U onto the spotting tile.
11. Repeat step 6 to step 9 with U. Record the colour in (a)(iii).
(iii)
State the colour for sample U.
[1]
© UCLES 2018
9700/31/M/J/18
5
www.dynamicpapers.com
Fig. 1.1 has only three colours. In (a)(ii) more than one of the known concentrations may
match U. This means that an estimate of the concentration of milk protein in U may not be
accurate.
(iv)
Using the result in (a)(iii), state the known concentrations of milk protein where the
colour result for U is the same.
[1]
(v)
A significant source of error in this procedure is the difficulty of matching the colour to
Fig. 1.1.
Complete Table 1.3 to suggest:
an improvement to this procedure of matching the colour (dependent variable)
one other significant source of error in this procedure
an improvement to reduce this error.
•
•
•
Table 1.3
significant source of error
improvement
matching the colour may be
inconsistent
another significant source of
error
[3]
(b) A student suggested that another procedure to estimate the concentration of protein in milk
could be to compare how much coagulation was produced in acidic conditions.
The student added acid to known concentrations of milk protein and observed a range of
coagulation. The concentration of milk protein in an unknown sample could then be estimated
more accurately.
You are provided with 1.0 mol dm–3 hydrochloric acid, labelled A.
It is recommended that you wear suitable eye protection.
If A comes into contact with your skin, wash it off immediately under cold water.
© UCLES 2018
9700/31/M/J/18
[Turn over
6
www.dynamicpapers.com
Read step 12 to step 16 before proceeding.
12. Put 10 cm3 of U into a test-tube.
In step 13, you will be adding A to the milk in the test-tubes, do not stir or mix A with the
milk.
13. Put 2 cm3 of A into each of the test-tubes containing the known concentrations of milk
protein (from step 4) and U.
14. Observe the changes in the milk in all of the test-tubes for up to 1 minute.
15. If coagulation is not visible after 1 minute, you may need to carefully tilt each test-tube to
move the milk and then observe the coagulation.
16. Using the observations from step 14 and step 15 and the key in Fig. 1.2, record the
results in (b)(i).
key
most coagulation
least coagulation
Fig. 1.2
(i)
Prepare the space below and record the results for the known concentrations of milk
protein using Fig. 1.2.
[2]
© UCLES 2018
9700/31/M/J/18
www.dynamicpapers.com
7
(ii)
Using the key in Fig. 1.2, record the result for U.
[1]
(iii)
Complete Fig. 1.3 to show the position on the line of each of the percentage
concentrations of milk decided in Table 1.2.
Put the label U on Fig. 1.3 to show an estimate of the concentration of milk which
provides a measure of the proteins in U, using the result in (b)(ii).
0.0%
1.0%
percentage concentration
of milk protein
Fig. 1.3
© UCLES 2018
9700/31/M/J/18
[2]
[Turn over
www.dynamicpapers.com
8
(c) Milk proteins can also be coagulated using the enzyme rennet.
A student investigated the effect of temperature on the activity of rennet, shown by the
percentage coagulation of the milk.
The results are shown in Table 1.4.
Table 1.4
(i)
temperature
/ °C
percentage
coagulation of the milk
8.5
7
28.0
63
35.5
84
41.0
92
50.0
39
Plot a graph of the data in Table 1.4 on the grid in Fig. 1.4.
Use a sharp pencil for drawing graphs.
Fig. 1.4
© UCLES 2018
9700/31/M/J/18
[4]
9
(ii)
www.dynamicpapers.com
Suggest explanations for the results between 35 °C and 45 °C.
[2]
(iii)
If a student wanted to investigate the independent variable, pH, a number of experiments
would need to be set up.
State the pH values you would select and describe how you would change the pH.
pH values
description
[1]
[Total: 22]
© UCLES 2018
9700/31/M/J/18
[Turn over
www.dynamicpapers.com
10
2
J1 is a slide of a stained transverse section through a plant leaf.
You are not expected to be familiar with this specimen.
(a) The specimen on J1 has an irregular shape.
Use a sharp pencil for drawings.
(i)
Draw a large plan diagram of the section of the leaf shown by the shaded area in Fig. 2.1.
Use one ruled label line and label to identify the vascular bundle.
draw this section
upper surface
lower surface
Fig. 2.1
You are expected to draw the correct shape and proportions of the different tissues.
[5]
© UCLES 2018
9700/31/M/J/18
11
(ii)
www.dynamicpapers.com
Observe the upper epidermis and palisade layer in the leaf (see Fig. 2.1).
Select one group of two adjacent, touching cells from the upper epidermis and one
adjacent, touching cell from the palisade tissue below.
Each cell must touch at least one of the other cells.
Make a large drawing of this group of three cells.
Use one ruled label line and label to identify the cell wall of one cell.
[4]
(iii)
Observe the leaf on J1.
Suggest one observable feature of J1 which supports the conclusion that this plant
grows in a dry environment.
Explain how this feature would prevent water loss.
feature
explanation
[2]
© UCLES 2018
9700/31/M/J/18
[Turn over
12
www.dynamicpapers.com
(b) Fig. 2.2 shows a diagram of a stage micrometer scale that is being used to calibrate an
eyepiece graticule.
One division, on either the stage micrometer scale or the eyepiece graticule, is the distance
between two adjacent lines.
The length of one division on this stage micrometer is 0.1 mm.
0
10 20 30 40 50 60 70 80 90 100
Fig. 2.2
(i)
Complete Fig. 2.3, by using Fig. 2.2 to calculate the actual length of one eyepiece
graticule unit.
Step 1
1 eyepiece graticule unit =
divided by
= mm
Step 2
Convert the answer to a measurement with the unit most suitable for use in light microscopy.
multiplied by
Fig. 2.3
© UCLES 2018
9700/31/M/J/18
=
[3]
www.dynamicpapers.com
13
Fig. 2.4 shows a photomicrograph of a transverse section through a leaf, taken using the
same microscope with the same lenses as Fig. 2.2.
You are not expected to be familiar with this specimen.
0
10 20 30 40 50 60 70 80 90 100
X
Y
Fig. 2.4
(ii)
Use the calibration of the eyepiece graticule unit from (b)(i) and Fig. 2.4 to calculate the
actual length of the plant leaf from X to Y.
Show all the steps in your calculation and use appropriate units.
[2]
© UCLES 2018
9700/31/M/J/18
[Turn over
14
(iii)
www.dynamicpapers.com
Fig. 2.5 is a photomicrograph of a transverse section of the same leaf as in Fig. 2.4.
Annotate Fig. 2.5 to describe two observable differences between the leaf in Fig. 2.5
and the leaf on J1:
•
Draw label lines to two different features and use only the labels P and Q.
•
Next to each letter, describe how each feature on the leaf in Fig. 2.5 differs from the
leaf on J1.
Fig. 2.5
[2]
[Total: 18]
© UCLES 2018
9700/31/M/J/18
15
BLANK PAGE
© UCLES 2018
9700/31/M/J/18
www.dynamicpapers.com
16
www.dynamicpapers.com
BLANK PAGE
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge International
Examinations Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download at www.cie.org.uk after
the live examination series.
Cambridge International Examinations is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of University of Cambridge Local
Examinations Syndicate (UCLES), which is itself a department of the University of Cambridge.
© UCLES 2018
9700/31/M/J/18