Biology (9700) · Feb/March 2018 · Mark scheme 52
Cambridge Biology (9700) mark scheme for paper 52, Feb/March 2018 — 9700/52/F/M/18, file 9700_m18_ms_52.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge Assessment International Education
Cambridge International Advanced Subsidiary and Advanced Level
BIOLOGY
9700/52
Paper 5 Planning, Analysis and Evaluation
March 2018
MARK SCHEME
Maximum Mark: 30
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge International will not enter into discussions about these mark schemes.
Cambridge International is publishing the mark schemes for the March 2018 series for most Cambridge
®
IGCSE , Cambridge International A and AS Level components and some Cambridge O Level components.
® IGCSE is a registered trademark.
This document consists of 10 printed pages.
© UCLES 2018
[Turn over
9700/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Generic Marking Principles
March 2018
www.dynamicpapers.com
These general marking principles must be applied by all examiners when marking candidate answers. They should be applied alongside the
specific content of the mark scheme or generic level descriptors for a question. Each question paper and mark scheme will also comply with these
marking principles.
GENERIC MARKING PRINCIPLE 1:
Marks must be awarded in line with:
•
•
•
the specific content of the mark scheme or the generic level descriptors for the question
the specific skills defined in the mark scheme or in the generic level descriptors for the question
the standard of response required by a candidate as exemplified by the standardisation scripts.
GENERIC MARKING PRINCIPLE 2:
Marks awarded are always whole marks (not half marks, or other fractions).
GENERIC MARKING PRINCIPLE 3:
Marks must be awarded positively:
•
•
•
•
•
marks are awarded for correct/valid answers, as defined in the mark scheme. However, credit is given for valid answers which go beyond the
scope of the syllabus and mark scheme, referring to your Team Leader as appropriate
marks are awarded when candidates clearly demonstrate what they know and can do
marks are not deducted for errors
marks are not deducted for omissions
answers should only be judged on the quality of spelling, punctuation and grammar when these features are specifically assessed by the
question as indicated by the mark scheme. The meaning, however, should be unambiguous.
GENERIC MARKING PRINCIPLE 4:
Rules must be applied consistently e.g. in situations where candidates have not followed instructions or in the application of generic level
descriptors.
© UCLES 2018
Page 2 of 10
9700/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
March 2018
www.dynamicpapers.com
GENERIC MARKING PRINCIPLE 5:
Marks should be awarded using the full range of marks defined in the mark scheme for the question (however; the use of the full mark range may
be limited according to the quality of the candidate responses seen).
GENERIC MARKING PRINCIPLE 6:
Marks awarded are based solely on the requirements as defined in the mark scheme. Marks should not be awarded with grade thresholds or
grade descriptors in mind.
© UCLES 2018
Page 3 of 10
9700/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Mark scheme abbreviations:
;
/
R
A
AW
underline
max
ora
mp
ecf
I
© UCLES 2018
separates marking points
alternative answers for the same marking point
reject
accept (for answers correctly cued by the question, or by additional guidance)
alternative wording (where responses vary more than usual)
actual word given must be used by candidate (grammatical variants accepted)
indicates the maximum number of marks that can be given
or reverse argument
marking point (with relevant number)
error carried forward
ignore
Page 4 of 10
March 2018
www.dynamicpapers.com
9700/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(a)
Answer
Marks
Guidance
1
85 (mg cm−3 )
−3
3
85 (mg cm ) × 35 (cm )
10 000 (cm3 )
= 0.30 (mg cm–3) ;
1(b)
March 2018
www.dynamicpapers.com
A 0.298 / 0.297
ref. to a named method of dilution or a description in words or a
diagram ;
3
A all marks on a fully labelled table
ref. to using correct proportions of stock solution and water to
make 100 cm3 ;
700 µg cm–3 and 200 µg cm–3 plus sensible choice of at least
three other intermediate concentrations described ;
e.g. (700) 575, 450, 325 (200) µg cm–3
(700) 600, 500, 400 300 (200) µg cm–3
1(c)
2
independent:
enzyme / lipase, concentration ;
dependent:
time (for pH) to reach 6.5 ;
1(d)
© UCLES 2018
any six from:
7
1
ref. to using same volume of each concentration of lipase
(in boiling tube) ;
2
ref. to method of measuring volume ;
2
e.g. graduated pipette / measuring cylinder /
syringe / burette
3
add, acid / alkali, to give pH 7.9 ;
3
R if buffer used
Page 5 of 10
9700/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(d)
Answer
4
idea of incubating enzyme (so it reaches the test
temperature) before adding cotton fabric ;
5
ref. to suitable incubation temperature ;
6
ref. to timing until pH reaches 6.5 ;
7
ref. to a suitable control ;
e.g. boiled enzyme / water with alkali
8
9
Marks
March 2018
www.dynamicpapers.com
Guidance
5
A a single temp range 20–60 °C
ref. to suitable method of keeping same incubation
temperature for all concentrations ;
8
e.g. incubator, water-bath, temperature-controlled
room
I air conditioning
ref. to using same, size / area, of stained fabric ;
9
A 20 mm × 20 mm pieces
10 ref. to, agitation / mixing / stirring ;
11 ref. to low / medium risk
or hazard and suitable safety precaution ;
11 e.g. allergy / sensitivity, to enzymes and wearing,
gloves / eye protection
12 ref. to minimum of 3 replicates / replicating the whole
experiment at least 3 times
and
finding a mean / to identify (and remove) anomalies
plus one required marking point:
13 ref. to immersing the cloth and starting
a, stop-clock / timer, simultaneously ;
1(e)(i)
© UCLES 2018
13 A starting, stop-clock / timer, immediately after
immersing the cloth
A ref. to pH meter instead of cloth since both will
be immersed at the same time according to Fig. 1.1
1
1
;
time ( for pH to fall to 6.5 )
Page 6 of 10
9700/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
1(e)(ii)
Answer
Marks
March 2018
www.dynamicpapers.com
Guidance
1
axes correctly orientated with labels ;
x-axis: concentration of lipase
y-axis: rate of, release of fatty acids / digestion of fats
2
axes have units ;
x-axis unit: µg cm–3
y-axis unit: s–1 or min–1
2
A arbitrary units or 1 / t(ime) on y-axis
3
line shows increase as lipase concentration increases ;
3
A linear curve or plateau
3
e.g.
rate of release of fatty
acids
/ s–1 or min–1
concentration of lipase
/ µg cm–3
1(e)(iii)
idea of rates calculated from times for pH to reach 6.5 for
washing liquids (from Table 1.1) ;
2
use of intercepts / described ;
1(f)
any one from:
idea that the lipase in A has a higher activity than that of B ;
idea that lipases are of, different types / different origin ;
idea that washing liquids and test solution are different (from
each other) ;
e.g. washing liquids contain other chemicals to remove fat
© UCLES 2018
Page 7 of 10
1
I ref. to optimum temperature
9700/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
2(a)
2(b)
Answer
Marks
any two from:
Guidance
2
1
volume of, liquid / (orange) juice, consumed ;
2
idea of: time between drinking liquid and time of test ;
e.g. left for 40 minutes before testing
3
sex / gender / all females ;
4
colour of light / flickering increases in even steps / time
intervals of increase are always the same / AW ;
5
(16) mg of alcohol in, drink / (orange) juice ;
6
time allowed for drinking ( 5 mins) ;
5
any two from:
A concentration of alcohol
2
idea of shows the spread about the mean / AW ;
indicates the reliability of the data ;
R accuracy
to put error bars on the graph / see if the standard deviations
overlap / see if the differences are significant ;
© UCLES 2018
March 2018
www.dynamicpapers.com
Page 8 of 10
9700/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
2(c)
© UCLES 2018
Answer
Marks
3
any three from:
1
the frequency at which flicker fusion occurs varies greatly
between individuals (with or without alcohol) ;
2
the frequency at which flicker fusion occurs is greater after
alcohol consumption / on day 2 (in, most of the women / 9
out of 13 women)
3
there is little variation in the repeated measurements on
day 1 or day 2 / result for individuals on day 1 or day 2 are
consistent ;
4
it takes longer to notice the change from flickering to fused
stimulus after alcohol consumption ;
5
(women) 4, 6 and 13, show little change / have lower
CFFT, after alcohol ;
7
ref. to overlapping error bars for, some women / 4, 5, 6, 7,
8, 11, 12, 13, suggests the effect of alcohol is not
significant
or
ref. to women with the highest flicker fusion (2 and 3) / 1, 2,
3, 9, do not have overlapping error bars so effect of alcohol
is significant ;
8
ref. to a range of values from lowest to highest ;
no alcohol: 17.3± 0.1 and 12.7± 0.1
alcohol: 18.5± 0.1 and 12.7± 0.1
Page 9 of 10
March 2018
www.dynamicpapers.com
Guidance
9700/52
Cambridge International AS/A Level – Mark Scheme
PUBLISHED
Question
2(d)
Answer
Marks
3
any three from:
very small sample / only 13 subjects ;
all test subjects are female ;
idea of habituation (as 10 tests carried out) ;
not all age ranges included ;
no indication of body mass ;
© UCLES 2018
Page 10 of 10
March 2018
www.dynamicpapers.com
Guidance