Chemistry (5070) · Oct/Nov 2021 · CI 31

Cambridge Chemistry (5070) ci for paper 31, Oct/Nov 2021 — 5070/31/O/N/21, file 5070_w21_ci_31.pdf.

Advertisement
Loading the paper…
Text of this paper

Cambridge O Level
CHEMISTRY

5070/31
October/November 2021

Paper 3 Practical Test
CONFIDENTIAL INSTRUCTIONS
* 9 9 5 9 2 3 4 2 6 5 *

This document gives details of how to prepare for and administer the practical exam.
The information in this document and the identity of any materials supplied by Cambridge International
are confidential and must NOT reach candidates either directly or indirectly.
The supervisor must complete the report at the end of this document and return it with the scripts.
INSTRUCTIONS
●
If you have any queries regarding these confidential instructions, contact Cambridge International
stating the centre number, the syllabus and component number and the nature of the query.
email
[email protected]
phone
+44 1223 553554

This document has 8 pages. Any blank pages are indicated.
DC (LK) 201162/2
© UCLES 2021

[Turn over

2

General information about practical exams
Centres must follow the guidance on science practical exams given in the Cambridge Handbook.

Safety
Supervisors must follow national and local regulations relating to safety and first aid.
Only those procedures described in the question paper should be attempted.
Supervisors must inform candidates that materials and apparatus used in the exam should be treated
with caution. Suitable eye protection should be used where necessary.
The following hazard codes are used in these confidential instructions, where relevant:
C
HH
F
N

corrosive
health hazard
flammable
hazardous to the aquatic environment

MH
T
O

moderate hazard
acutely toxic
oxidising

Hazard data sheets relating to substances used in this exam should be available from your chemical
supplier.

Before the exam
●
●
●

The packets containing the question papers must not be opened before the exam.
It is assumed that standard school laboratory facilities, as indicated in the Guide to Planning
Practical Science, will be available.
Spare materials and apparatus for the tasks set must be available for candidates, if required.

During the exam
●
●
●
●

It must be made clear to candidates at the start of the exam that they may request spare materials
and apparatus for the tasks set.
Where specified, the supervisor must perform the experiments and record the results as instructed.
This must be done out of sight of the candidates, using the same materials and apparatus as the
candidates.
Any assistance provided to candidates must be recorded in the supervisor’s report.
If any materials or apparatus need to be replaced, for example, in the event of breakage or loss,
this must be recorded in the supervisor’s report.

After the exam
●
●

The supervisor must complete a report for each practical session held and each laboratory used.
Each packet of scripts returned to Cambridge International must contain the following items:
–
the scripts of the candidates specified on the bar code label provided
–
the supervisor’s results relevant to these candidates
–
the supervisor’s reports relevant to these candidates
–
seating plans for each practical session, referring to each candidate by candidate number
–
the attendance register.

© UCLES 2021

5070/31/CI/O/N/21

3

Specific information for this practical exam
During the exam, the supervisor (not the invigilator) must do all the experiments and record the
results on a spare copy of the question paper, clearly labelled ‘supervisor’s results’.
If chemicals are prepared in more than one batch, clearly labelled supervisor’s results must be
provided for each batch. The candidates using each batch must be listed on the supervisor’s report.
Apparatus
The apparatus listed must be provided to each candidate.
1 × 25 cm3 pipette
1 × pipette filler
1 × 50 cm3 burette
1 × stand
1 × burette clamp
1 × funnel for filling burette
1 × white tile
1 × conical flask suitable for titration
a supply of test-tubes
1 × test-tube rack (to support test-tubes and boiling tubes)
1 × test-tube holder (to hold test-tubes and boiling tubes)
1 × stirring rod
2 × boiling tubes
1 × Bunsen burner
1 × heat-proof mat
4 × teat/dropping pipettes
1 × beaker (for washing teat/dropping pipettes)
1 × spatula
1 × wash bottle containing distilled water
paper towels
red and blue litmus papers or universal indicator paper
wooden splints
apparatus normally used in the centre in testing for carbon dioxide with limewater

© UCLES 2021

5070/31/CI/O/N/21

[Turn over

© UCLES 2021

Q

0.24 mol / dm3 sodium
carbonate solution

0.40 mol / dm3 dilute nitric
acid
methyl orange indicator

150 cm3
5 cm3

identity

150 cm3

per
candidate

See preparation instructions on page 30 of the 2020–2021
syllabus.

Dissolve 25 cm3 of 70% HNO3 [C][O] in each dm3 of
solution.

Dissolve 68.64 g of Na2CO3.10H2O [MH] in 700 cm3 of
distilled water and make up to 1000 cm3 with distilled water.
This solution must be prepared using newly purchased
sodium carbonate.

notes

R

S

T

manganese(IV) oxide

magnesium turnings

[MH]

[C]

[MH]

[MH]

5070/31/CI/O/N/21

[F]

0.1 mol / dm3 copper(II)
sulfate solution

10 cm3

0.5 g

magnesium turnings

manganese(IV) oxide
granules or small lumps

0.4 mol / dm3 calcium iodide
solution

10 cm3

1g

20 vol H2O2

10 cm3

If magnesium turnings are not available, finely chopped
magnesium ribbon may be substituted.

Dissolve 24.97 g of CuSO4.5H2O [C][MH][N] in each dm3 of
solution.

Dissolve 94.5 g of Ca(NO3 )2.4H2O [O][C] and 132.8 g of KI
in each dm3 of solution.

Dilute 200 cm3 of 100 vol (approximately 8.3 mol / dm3)
H2O2 [C] with 700 cm3 distilled water and make up to
1000 cm3 with distilled water. This solution must be freshly
prepared using newly purchased hydrogen peroxide.

Supervisors are asked to carry out a standard acid/base titration between solutions P and Q to ensure that the concentrations of the two solutions
fall within the given range. It is essential that 25.0 cm3 of P reacts with between 28.0 cm3 and 32.0 cm3 of Q.

[F] [MH] methyl orange indicator
[HH] [T]
[N] [C]

[MH]

P

label

The materials listed in the table must be provided to each candidate.

Materials

4

1.0 mol / dm3 NaOH
0.05 mol / dm3 AgNO3
saturated aqueous
calcium hydroxide, Ca(OH)2

15 cm3
10 cm3
10 cm3

aqueous silver nitrate

© UCLES 2021

If you are unable to source any of these chemicals, you must contact Cambridge International as far as possible in advance of the exam for
advice.

Materials must be labelled only as specified in the ‘label’ column. The identities of chemicals labelled with letter codes, e.g. P, may
be different from their descriptions in the question paper. Candidates must use the descriptions given in the question paper.

●

●

All solutions must be thoroughly mixed.

●

Invigilators must be alert to the risk of contamination and the
opportunity for malpractice when using a communal supply.

If necessary, each of these reagents can be provided as a
communal supply for groups of up to 6 candidates.

An excess of at least 10% of each material must be prepared to cover accidental loss.

limewater

notes
See preparation instructions on page 30 of the 2020–2021
syllabus.

●

[MH]

[C]

aqueous sodium hydroxide

aqueous ammonia

[MH]
[N]

1.0 mol / dm3 NH3

dilute nitric acid

[C]
10 cm3

identity
1.0 mol / dm3 HNO3

per
candidate
10 cm3

label

5

5070/31/CI/O/N/21

[Turn over

6
BLANK PAGE

Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of the University of
Cambridge Local Examinations Syndicate (UCLES), which itself is a department of the University of Cambridge.

© UCLES 2021

5070/31/CI/O/N/21

7

Supervisor’s report
Syllabus and component number

/

Centre number
Centre name
Time of the practical session
Laboratory name/number
Give details of any difficulties experienced by the centre or by candidates (include the relevant
candidate names and candidate numbers).
You must include:
● any difficulties experienced by the centre in the preparation of materials
● any difficulties experienced by candidates, e.g. due to faulty materials or apparatus
● any specific assistance given to candidates.

© UCLES 2021

5070/31/CI/O/N/21

[Turn over

8
If chemicals have been prepared in more than one batch, list the candidates using each batch.

Declaration
1 Each packet that I am returning to Cambridge International contains all of the following items:
● the scripts of the candidates specified on the bar code label provided
● the supervisor’s results relevant to these candidates
● the supervisor’s reports relevant to these candidates
● seating plans for each practical session, referring to each candidate by candidate number
● the attendance register.
2 Where the practical exam has taken place in more than one practical session, I have clearly
labelled the supervisor’s results, supervisor’s reports and seating plans with the time and laboratory
name/number for each practical session.
3 I have included details of difficulties relating to each practical session experienced by the centre or
by candidates.
4 I have reported any other adverse circumstances affecting candidates, e.g. illness, bereavement or
temporary injury, directly to Cambridge International on a special consideration form.
Signed (supervisor)
Name (in block capitals)
© UCLES 2021

5070/31/CI/O/N/21

Advertisement