Physics (5054) · Oct/Nov 2016 · Mark scheme 31
Cambridge Physics (5054) mark scheme for paper 31, Oct/Nov 2016 — 5054/31/O/N/16, file 5054_w16_ms_31.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International Examinations
Cambridge Ordinary Level
PHYSICS
5054/31
Paper 3 Practical Test
October/November 2016
MARK SCHEME
Maximum Mark: 30
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the October/November 2016 series for most
®
Cambridge IGCSE , Cambridge International A and AS Level components and some Cambridge O Level
components.
® IGCSE is the registered trademark of Cambridge International Examinations.
This document consists of 3 printed pages.
© UCLES 2016
[Turn over
www.dynamicpapers.com
Page 2
1
Mark Scheme
Cambridge O Level – October/November 2016
Syllabus
5054
(a) (i) L0 measured to the nearest mm or better and in the range 1.5 cm to 3.0 cm
with consistent unit seen here or in (a)(ii), (a)(iii), (b)(i) or (b)(ii)
B1
(ii)(iii) L1 recorded to the nearest mm or better and e1 calculated correctly with
consistent unit seen here or in (a)(i), (b)(i) or (b)(ii)
B1
(b) e2 < e1.
M1
(c) ρ calculated correctly to 2 / 3s.f. with unit
A1
value in range 1.0 g / cm3 to 2.0 g / cm3
2
3
Paper
31
(a) (i) bottom of the threads are separated by 30.0 cm so the top of the threads
must be separated by the same distance owtte / vertical alignment with
stands / doorframe etc
A1
B1
(ii) ensure that the half-metre rule is horizontal by measuring the height above
the bench at each end and finding that they are the same.
or aligning with a horizontal line in the room, e.g. windowsill / top of door
B1
(b) t in the range 8 s to 16 s with unit seen somewhere in (b) and using at least one
repeat measurement with correct average
B1
T calculated correctly to 2 / 3 s.f. with unit seen somewhere
B1
T in the range 1.0 s to 1.4 s, when rounded
B1
(a) V1 in the range 0.55 V to 0.90 V to 0.01 V or better with unit seen here or in (c)
and I1 in the range 0.30 A to 0.50 A to 0.01 A or better with unit seen here or in (c)
B1
(b) correct calculation of R1 in the range 1.0 Ω to 3.0 Ω with unit seen here or in (d)
B1
(c) V2 < V1 and in the range 0.55 V to 0.90 V to 0.01 V or better with unit seen here or
in (a)
and I2 < I1 and in the range 0.14 A to 0.27 A to 0.01 A or better with unit seen here
or in (a)
B1
(d) correct calculation of R2 with R2 > R1 with unit seen here or in (b)
B1
(e) when the current decreases, the voltage across the diode decreases (slightly)
and the resistance of the diode increases or vice versa and
comment consistent with results
B1
© UCLES 2016
[5]
[5]
[5]
www.dynamicpapers.com
Page 3
4
Mark Scheme
Cambridge O Level – October/November 2016
Syllabus
5054
Paper
31
Preliminary results
(a) (i) Approached the formation of the sharp image on the screen from both
directions.
(ii) uS in the range 79.0 cm to 84.0 cm.
Repeated measurements, correctly averaged with unit seen here or in (b)(i)
(b) (i) uL in the range 16.0 cm to 21.0 cm with unit seen here or in (a)(ii).
(ii) d and y calculated correctly (ignore units and s.f.)
B1
M1
A1
B1
B1
[5]
(c) Table
column headings for D, uS, uL, d and y and units for D, d and y and results from
(a)(ii) and (b) included
B1
correct calculation of d and y
B1
D values in the range 65.0 cm ⩽ D ⩽ 95.0 cm
B1
at least 5 results showing correct trend, y increases as D increases
B1
[4]
(d) Graph
axes labelled with units and correct orientation.
(allow e.c.f. from wrong unit in table but not no units)
B1
suitable scale, not based on 3, 6, 7 etc. with plotted data occupying ⩾ half the
page in both directions.
(allow origin, if present, to be included)
B1
two points plotted correctly – check the two points furthest from the line. This
mark can only be scored if the scale is easy to follow
(points must be within ½ small square of the correct position)
B1
best fit fine straight line and fine points or crosses
(line thickness to be no greater than the thickest lines on the grid)
B1
[4]
(e) Calculations
use of two points that are on the straight line or two points on a tangent drawn to
the curve.
M0
(i) use of a triangle that uses more than half the drawn line to calculate the
gradient
A1
(ii) f in the range 13 (cm) to 17 (cm). (Ignore s.f. and unit)
A1
© UCLES 2016
[2]