Physics (5054) · May/June 2017 · Mark scheme 41

Cambridge Physics (5054) mark scheme for paper 41, May/June 2017 — 5054/41/M/J/17, file 5054_s17_ms_41.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

Cambridge International Examinations
Cambridge Ordinary Level

PHYSICS

5054/41

Paper 4 Alternative to Practical

May/June 2017

MARK SCHEME
Maximum Mark: 30

Published

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2017 series for most Cambridge IGCSE®,
Cambridge International A and AS Level and Cambridge Pre-U components, and some Cambridge O Level
components.

® IGCSE is a registered trademark.

This document consists of 5 printed pages.
© UCLES 2017

[Turn over

5054/41

Cambridge O Level – Mark Scheme
PUBLISHED

Question

Answer

May/June 2017
www.dynamicpapers.com

Marks

1(a)(i)

decelerating

B1

1(a)(ii)

less distance travelled in equal time / 0.020 s

B1

table of two columns – one with heading time / s (or t / s)

B1

second column with heading distance / cm (or d / cm or s / cm)

B1

correct data in table – any 3 correct lines

C1

4 correct lines

A1

12 / .06 = 200 cm / s or 2 m / s

B1

1(b)

1(c)

© UCLES 2017

Page 2 of 5

5054/41

Cambridge O Level – Mark Scheme
PUBLISHED

Question

May/June 2017
www.dynamicpapers.com

Answer

Marks

2(a)

35.4 (s)

B1

2(b)

axes labelled quantity and unit
axes correct way round

B1

scales linear, not awkward, start from (0,0)

B1

points plotted accurately

B1

smooth best fit curve drawn

B1

31.06 / 31.1

B1

31 cao

A1

2(d)

curved line of similar shape below original line

B1

2(e)

takes a long time (for last few cm) / would not empty completely / difficult to judge when empty / low pressure

B1

2(c)

© UCLES 2017

Page 3 of 5

5054/41

Cambridge O Level – Mark Scheme
PUBLISHED

Question

May/June 2017
www.dynamicpapers.com

Answer

Marks

3(a)(i)

line through each pair of dots to mirror and line joined between mirrors – correct by eye

B1

3(a)(ii)

described:
line through P1 and P2 and line through P3 and P4

B1

described:
joining the two lines in the middle at the points where the lines meet the mirror

B1

lines through the centre of the blobs / a thin line drawn / use of a sharp pencil / any sensible precaution

B1

normal drawn at Q by eye

B1

3(b)(iii)

i = 44° ± 1°

B1

3(b)(iv)

r = 47° ± 1°

B1

P3 and P4 further apart / line up the bases of the pins / ensure pins are vertical

B1

3(a)(iii)
3(b)(i), (ii)

3(c)

© UCLES 2017

Page 4 of 5

5054/41

Cambridge O Level – Mark Scheme
PUBLISHED

Question

May/June 2017
www.dynamicpapers.com

Answer

Marks

4(a)

top box – ammeter
bottom box – voltmeter

B1

4(b)

meter 1 – current
meter 2 – voltage / p.d / emf

B1

4(c)

meter 1 = 0.24 A

B1

meter 2 = 7.2 V

B1

4(d)

R = 30 ohms

B1

4(e)

check zero error / tap to avoid sticking / switch off to prevent overheating / parallax in reading scale / tight connections any
other sensible precaution

B1

© UCLES 2017

Page 5 of 5

Advertisement