Physics (5054) · May/June 2017 · Mark scheme 32
Cambridge Physics (5054) mark scheme for paper 32, May/June 2017 — 5054/32/M/J/17, file 5054_s17_ms_32.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International Examinations
Cambridge Ordinary Level
PHYSICS
5054/32
Paper 3 Practical Test
May/June 2017
MARK SCHEME
Maximum Mark: 30
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2017 series for most Cambridge IGCSE®,
Cambridge International A and AS Level and Cambridge Pre-U components, and some Cambridge O Level
components.
® IGCSE is a registered trademark.
This document consists of 6 printed pages.
© UCLES 2017
[Turn over
5054/32
Cambridge O Level – Mark Scheme
PUBLISHED
Question
1(a)
Answer
May/June 2017
www.dynamicpapers.com
Marks
evidence of repeats used to obtain t
seen in (a) or (b)
B1
t1 = 4 ± 1 s or centre value ± 1 s
B1
1(b)
any t1 < t2 and correct unit seen in (a) or (b)
B1
1(c)
t1 / t2 in range 1.80 to 2.20
B1
ratio correct , given to 2 or 3 s.f. with no unit
B1
© UCLES 2017
Page 2 of 6
5054/32
Cambridge O Level – Mark Scheme
PUBLISHED
Question
2(a)
2(b)(i)
Answer
May/June 2017
www.dynamicpapers.com
Marks
length given to nearest mm, with unit, and to centre value ± 1.0 cm
if no centre value (from supervisor or candidate scripts), allow in range 8.0–11.0 cm
B1
vary / measure the distance between the lamp and the object / along XZ(owtte) (1)
B2
compare / measure (the length of) the shadow (along PZQ) (owtte) (1)
allow 1 mark for ‘move object and measure shadow’
max 1 mark if lamp moved
2(b)(ii)
© UCLES 2017
y-axis labelled: length of shadow / PZQ, units not required
C1
straight line decreasing or curve decreasing
A1
Page 3 of 6
5054/32
Cambridge O Level – Mark Scheme
PUBLISHED
Question
Answer
May/June 2017
www.dynamicpapers.com
Marks
3(a)(i)
centre value ± 0.5 V or 1.5 to 3.5 V, readings to at least 0.1 V, with unit
B1
3(a)(ii)
centre value ± 0.5 V or 1.5 to 2.2 V, readings to at least 0.1 V, with unit
B1
3(a)(iii)
VAC in range (VAB + VBC) ± 0.2
allow centre value ± 0.2
B1
3(b)
current, I, with unit e.g. 0.0089 A ( i.e. (a)(i) / 330)
B1
3(c)
resistance RL to 2 or 3 s.f. with unit e.g. 224 Ω
allow centre value ± 30 ohms or ecf (a)(ii) / (b) in range 150–250 ohms if no centre
value available
B1
© UCLES 2017
Page 4 of 6
5054/32
Cambridge O Level – Mark Scheme
PUBLISHED
Question
4(a)
May/June 2017
www.dynamicpapers.com
Answer
Marks
room temperature close to centre value if given or in range 15–45 °C
unit required, accept correct symbol or 'Celsius'
B1
4(b)(i)
current I less than 1 A to at least 1 d.p.
unit required
B1
4(b)(ii)
sensible value for P (b)(i)2 × 4 in range 0.1 W up to 4 W
B1
4(c)(i)
headings for table, with units: temperature / °C time / s
B1
4(c)(iii)
correct trend in results: temperature increases with time
C1
temperature rises increase by 2.0 °C from θr
C1
all times and temperatures present, starting with θ = (θ r + 2) (additions all performed) and finishing at θ = (θ r + 18)
A1
graph: axes labelled, with units, temperature on the x-axis
B1
suitable scale, not based on 3, 6, 7 etc. with plotted data occupying at least half the page in both directions; the origin may be
included
B1
all the data in table plotted, points plotted correctly on a scale that is easy to follow at least two points checked, points must be
within ½ small square of the correct position
B1
best fit, fine line (curved or straight) and fine points or crosses
B1
4(d)
© UCLES 2017
Page 5 of 6
5054/32
Cambridge O Level – Mark Scheme
PUBLISHED
Question
4(e)
May/June 2017
www.dynamicpapers.com
Answer
Marks
tangent drawn to the curved best line at (θr + 11) °C
M1
correct calculation of the gradient, given to 2 / 3 s.f., ignore any units
A1
a large gradient triangle used, based on the tangent used
B1
or
© UCLES 2017
(in cases where there is no obvious curve indicated by the plotted data and a best fit straight line has been drawn then allow
calculation of the gradient using a gradient triangle including (θr + 11) °C)
(M1)
correct calculation of the gradient, given to 2 / 3 s.f., ignore any units
(A1)
a large gradient triangle used centred near or on (θr + 11) °C
(B1)