Physics (5054) · May/June 2005 · Mark scheme 3

Cambridge Physics (5054) mark scheme for paper 3, May/June 2005 — 5054/3/M/J/05, file 5054_s05_ms_3.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS
General Certificate of Education O Level

MARK SCHEME for the June 2005 question paper

5054 PHYSICS
5054/03

Paper 3 (Practical Test), maximum mark 30

These mark schemes are published as an aid to teachers and students, to indicate the requirements
of the examination. They show the basis on which Examiners were initially instructed to award marks.
They do not indicate the details of the discussions that took place at an Examiners’ meeting before
marking began. Any substantial changes to the mark scheme that arose from these discussions will
be recorded in the published Report on the Examination.
All Examiners are instructed that alternative correct answers and unexpected approaches in
candidates’ scripts must be given marks that fairly reflect the relevant knowledge and skills
demonstrated.
Mark schemes must be read in conjunction with the question papers and the Report on the
Examination.

•

CIE will not enter into discussion or correspondence in connection with these mark schemes.

CIE is publishing the mark schemes for the June 2005 question papers for most IGCSE and GCE
Advanced Level and Advanced Subsidiary Level syllabuses and some Ordinary Level syllabuses.

www.dynamicpapers.com

June 2005

GCE O Level

MARK SCHEME
MAXIMUM MARK: 30

SYLLABUS/COMPONENT: 5054/03
PHYSICS
Paper 3 (Practical Test)

Page 1

1

(a)
(b)

(c)

(d)

2

(a)
(b)
(c)

(d)

3

(a), (b), (c)

(d)

www.dynamicpapers.com

Mark Scheme
GCE O Level – June 2005

Syllabus
5054

Paper
3

Sensible l (approximately 80 cm to 90 cm) with unit seen
here or in part (b)

M1

Correct calculation of D giving sensible answer
(approximately 7 cm) to 2/3 s.f. with unit seen here or in
part (a)

A1

Sensible d (approximately 6 - 7 cm) and sensible h
(approximately 10 cm) both recorded to the nearest mm
with unit

B1

Sensible value for M (approximately 100 g) and correct
substitution into the formula for density provided
substitution leads to a non-negative value

M1

Density in range 0.5 to 5.0 g/cm3 with unit.

A1 [5]

Time recorded to the nearest second or better and in the
region of 75 seconds with unit

B1

Time recorded to the nearest second or better and
significantly smaller than the time in (a) with unit

B1

Precautions;
Stirring the water before taking the reading
Reading the thermometer with the eye level with the
meniscus
Bulb of the thermometer not touching the side or base of
the beaker

B1

B1

(No e.c.f. to this choice). 250 cm3 beaker cools more
rapidly because;
the same temperature fall occurs in a shorter time/
there is a greater surface area of water in contact with the air
that allows more thermal energy to escape from the water/
the greater mass of the larger beaker absorbs more
thermal energy

B1 [5]

Sensible I for V = 6 V and table with units
All V sensible and correct to at least 2 s.f.
All I sensible and correct to at least 2 s.f.
Correct trend in R values. (R increases as V increases)
Comment that R increases as V increases (no e.c.f.)

B1
B1
B1
B1
B1 [5]

© University of Cambridge International Examinations 2005

www.dynamicpapers.com

Page 2

4

Mark Scheme
GCE O Level – June 2005

Syllabus
5054

Paper
3

Initial Measurements
(a)

(b)

Sensible h (approx 5 cm) recorded to the nearest mm
Set square correctly placed between desk and rule or
vertical rule and ball

B1

10 T repeated and averaged
Sensible T determined from 10 T with unit
(Not allow nearest second in 10 T)

B1
B1 [4]

Table with units for h, 10 T, T and T2
h varied over a range of at least 20 cm
At least 5 points with correct trend (T decreases as h
increases)

B1
B1
B1

Correct calculation of T2 values to ≥ 3 s.f.

B1 [4]

Axes labelled with units and correct orientation
(penalise if graph of T/s plotted against h/cm)
Suitable scale, not based on 3, 6, 7 etc. with data
occupying more than half the page in both directions
Two points plotted correctly - check the two points
furthest from the line. This mark can only be scored if the
scale is easy to follow
Best fit line and fine points

B1

Use of large triangle with base ≥ 8 cm or height ≥ 12 cm
Correct reading of sides of triangle with straight
hypotenuse
Negative sign and value in range 0.038 to 0.042 (s2/cm)
to ≥ 2 s.f.
(Allow 0.04 for 0.040 and ignore missing unit)

B1

B1

Table
(c)

(d)
Graph
(e)

B1
B1
B1 [4]

Calculations
(f)

© University of Cambridge International Examinations 2005

B1
B1 [3]

Advertisement