Co-ordinated Sciences (0654) · May/June 2024 · CI 51
Cambridge Co-ordinated Sciences (0654) ci for paper 51, May/June 2024 — 0654/51/M/J/24, file 0654_s24_ci_51.pdf.
Text of this paper
Cambridge IGCSE™
CO‑ORDINATED SCIENCES
0654/51
May/June 2024
Paper 5 Practical Test
CONFIDENTIAL INSTRUCTIONS
* 4 4 4 9 0 7 7 2 4 0 *
This document gives details of how to prepare for and administer the practical exam.
The information in this document and the identity of any materials supplied by Cambridge International
are confidential and must NOT reach candidates either directly or indirectly.
The supervisor must complete the report at the end of this document and return it with the scripts.
INSTRUCTIONS
●
If you have any queries regarding these confidential instructions, contact Cambridge International
stating the centre number, the syllabus and component number and the nature of the query.
email
[email protected]
phone
+44 1223 553554
This document has 12 pages. Any blank pages are indicated.
DC (SL/SG) 330110/2
© UCLES 2024
[Turn over
2
General information about practical exams
Centres must follow the guidance on science practical exams given in the Cambridge Handbook.
Safety
Supervisors must follow national and local regulations relating to safety and first aid.
Only those procedures described in the question paper should be attempted.
Supervisors must inform candidates that materials and apparatus used in the exam should be treated
with caution. Suitable eye protection should be used where necessary.
The following hazard codes are used in these confidential instructions, where relevant:
C
HH
F
N
corrosive
health hazard
flammable
hazardous to the aquatic environment
MH
T
O
moderate hazard
acutely toxic
oxidising
Hazard data sheets relating to substances used in this exam should be available from your chemical
supplier.
Before the exam
●
●
●
The packets containing the question papers must not be opened before the exam.
It is assumed that standard school laboratory facilities, as indicated in the Guide to Planning
Practical Science, will be available.
Spare materials and apparatus for the tasks set must be available for candidates, if required.
During the exam
●
●
●
●
It must be made clear to candidates at the start of the exam that they may request spare materials
and apparatus for the tasks set.
Where specified, the supervisor must perform the experiments and record the results as instructed.
This must be done out of sight of the candidates, using the same materials and apparatus as the
candidates.
Any assistance provided to candidates must be recorded in the supervisor’s report.
If any materials or apparatus need to be replaced, for example, in the event of breakage or loss,
this must be recorded in the supervisor’s report.
After the exam
●
●
The supervisor must complete a report for each practical session held and each laboratory used.
Each packet of scripts returned to Cambridge International must contain the following items:
–
the scripts of the candidates specified on the bar code label provided
–
the supervisor’s results relevant to these candidates
–
the supervisor’s reports relevant to these candidates
–
seating plans for each practical session, referring to each candidate by candidate number
–
the attendance register.
© UCLES 2024
0654/51/CI/M/J/24
3
Specific information for this practical exam
During the exam, the supervisor (not the invigilator) must do the experiment in Questions 1, 2, 3,
4 and 5 and record the results on a spare copy of the question paper, clearly labelled ‘supervisor’s
results’.
Question 1
Each candidate should be provided with:
hazard
materials and apparatus
quantity per
candidate
freshly cut slice of a citrus fruit, e.g. orange (see note 1)
1
white tile
1
30 cm ruler graduated in mm
1
Notes
1.
The fruit should be sliced so that the segments are clearly visible as shown in Fig. 1.1.
Fig. 1.1
© UCLES 2024
0654/51/CI/M/J/24
[Turn over
4
Question 2
Each candidate should be provided with:
hazard
[HH]
[MH] [N]
materials and apparatus
0.1% DCPIP labelled DCPIP supplied with a dropper (see note 1)
white spotting tile
quantity per
candidate
10 cm3
1
orange juice labelled orange juice supplied with a dropper (see note 2)
5 cm3
apple or white grape juice labelled juice F supplied with a dropper (see
note 3)
5 cm3
water containing a dissolved vitamin C tablet labelled juice E supplied
with a dropper (see note 4)
5 cm3
water containing a dissolved vitamin C tablet labelled juice D supplied
with a dropper (see note 5)
5 cm3
paper towels
3
Notes
1.
The 0.1% DCPIP can be made by dissolving 0.1 g of DCPIP powder in 100 cm3 of distilled water or
can be made from a stock solution diluted accordingly.
2.
This can be from freshly squeezed oranges or purchased as juice. The juice should be decanted
from any pulp and needs to be clear.
3.
Fresh fruit can be squeezed but the juice needs to be clear juice (not cloudy) without pulp.
4.
Prior to the examination, one vitamin C tablet should be added to 200 cm3 of water and fully
dissolved.
5.
Prior to the examination, one vitamin C tablet should be added to 100 cm3 of water and fully
dissolved.
6.
Prior to the examination, using a spotting tile with 2 drops of DCPIP in each of four wells and
adding dropwise, test juices D, E, F and orange juice ensuring that the DCPIP is decolourised
before each well is full and all juices give different results. The concentration of the DCPIP or fruit
juice may be adjusted to achieve this.
© UCLES 2024
0654/51/CI/M/J/24
5
Question 3
Each candidate should be provided with:
hazard
materials and apparatus
quantity per
candidate
[C][MH]
[N]
1.0 mol dm–3 aqueous copper(II) sulfate labelled 1.00 M copper sulfate
(see note 1)
35 cm3
[C][N]
0.75 mol dm–3 aqueous copper(II) sulfate labelled 0.75 M copper sulfate
(see note 1)
35 cm3
[C][N]
0.5 mol dm–3 aqueous copper(II) sulfate labelled 0.50 M copper sulfate
(see note 1)
35 cm3
[C][N]
0.25 mol dm–3 aqueous copper(II) sulfate labelled 0.25 M copper sulfate
(see note 1)
35 cm3
[F]
6 spatula
loads
magnesium powder
container to hold waste solutions (approximately 500 cm3 of waste will be
generated) labelled waste (see note 2)
1
polystyrene cup
1
beaker to hold the polystyrene cup
1
thermometer –10 °C to +110 °C with 1 °C graduations suitable for stirring
1
25 cm3 measuring cylinder
1
spatula
1
paper towels
5
access to water for rinsing polystyrene cup
Notes
1.
The aqueous copper sulfate will need to be poured from the container it is supplied in.
2.
Each candidate needs their own waste container.
© UCLES 2024
0654/51/CI/M/J/24
[Turn over
6
Question 4
Each candidate should be provided with:
hazard
[MH]
[C]
materials and apparatus
quantity per
candidate
1.0 mol dm–3 aqueous potassium chloride labelled H
20 cm3
0.5 mol dm–3 aqueous ammonia labelled aqueous ammonia
6 cm3
0.4 mol dm–3 aqueous sodium hydroxide labelled aqueous sodium
hydroxide
6 cm3
access to 1.0 mol dm–3 nitric acid labelled dilute nitric acid (see note 1)
access to 0.1 mol dm–3 aqueous barium nitrate labelled aqueous barium
nitrate, supplied in a bottle with a dropper or with a dropping pipette (see
note 1)
access to 0.05 mol dm–3 aqueous silver nitrate labelled aqueous silver
nitrate, supplied in a dark bottle with a dropper (see note 1)
test-tubes (approximately 125 mm × 16 mm)
5
means to support test-tubes
1
wooden splints
2
Bunsen burner and a means to light it
1
laboratory mat
1
paper towels
3
Notes
1.
Each candidate will need to use approximately 3 cm3 of dilute nitric acid, 1 cm3 of aqueous barium
nitrate and a few drops of aqueous silver nitrate. If these reagents are shared, no more than
4 candidates should share each sample.
© UCLES 2024
0654/51/CI/M/J/24
7
Question 5
Each candidate should be provided with:
hazard
quantity per
candidate
materials and apparatus
d.c. power source of approximately 2 V to 3 V (see notes 2 and 3)
1
2.5 V, 0.2 A lamp, or similar, in a suitable holder
1
voltmeter capable of measuring the supply voltage with a minimum
precision of 0.1 V (see note 4)
1
ammeter capable of reading up to 1.00 A with a minimum precision of
0.02 A (see note 4)
1
switch. The switch may be an integral part of the power supply
1
wooden or plastic metre rule graduated in millimetres
1
approximately 105 cm of straight, bare constantan wire of diameter
0.31 mm (30 swg), taped to the metre rule at two places (between the zero
and 5.0 cm mark and between the 95.0 and 100.0 cm mark). The zero end
of the wire is to be labelled P and the other end is to be labelled Q
1
suitable terminal (e.g. a crocodile clip) attached to the constantan wire at
end P of the metre rule, so that a connecting lead can be attached to the
resistance wire
1
sliding contact labelled S. This may be a crocodile clip connected to a lead
1
Notes
1.
The circuit shown in Fig. 5.1 is to be set up for candidates by the supervisor. The switch must be
left open.
V
A
l
S
P
resistance wire
Q
metre rule
Fig. 5.1
2.
If candidates are supplied with a power source of variable voltage output, the voltage should be
set by the supervisor and fixed (e.g. taped).
3.
If dry cells are used, check that they are adequately charged. Spare cells should be available.
© UCLES 2024
0654/51/CI/M/J/24
[Turn over
8
4.
Either analogue or digital meters are suitable. Any variable settings should be set by the Supervisor
and fixed (e.g. taped).
Action at changeover
Check that the circuit is still connected correctly, working and switched off.
Question 6
No apparatus or materials are required for Question 6.
© UCLES 2024
0654/51/CI/M/J/24
9
BLANK PAGE
© UCLES 2024
0654/51/CI/M/J/24
[Turn over
10
BLANK PAGE
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
Local Examinations Syndicate (UCLES), which is a department of the University of Cambridge.
© UCLES 2024
0654/51/CI/M/J/24
11
Supervisor’s report
Syllabus and component number
/
Centre number
Centre name
Time of the practical session
Laboratory name/number
Give details of any difficulties experienced by the centre or by candidates (include the relevant
candidate names and candidate numbers).
You must include:
● any difficulties experienced by the centre in the preparation of materials
● any difficulties experienced by candidates, e.g. due to faulty materials or apparatus
● any specific assistance given to candidates.
© UCLES 2024
0654/51/CI/M/J/24
[Turn over
12
Declaration
1 Each packet that I am returning to Cambridge International contains all of the following items:
● the scripts of the candidates specified on the bar code label provided
● the supervisor’s results relevant to these candidates
● the supervisor’s reports relevant to these candidates
● seating plans for each practical session, referring to each candidate by candidate number
● the attendance register.
2 Where the practical exam has taken place in more than one practical session, I have clearly
labelled the supervisor’s results, supervisor’s reports and seating plans with the time and laboratory
name/number for each practical session.
3 I have included details of difficulties relating to each practical session experienced by the centre or
by candidates.
4 I have reported any other adverse circumstances affecting candidates, e.g. illness, bereavement or
temporary injury, directly to Cambridge International on a special consideration form.
Signed (supervisor)
Name (in block capitals)
© UCLES 2024
0654/51/CI/M/J/24