Co-ordinated Sciences (0654) · May/June 2023 · CI 53
Cambridge Co-ordinated Sciences (0654) ci for paper 53, May/June 2023 — 0654/53/M/J/23, file 0654_s23_ci_53.pdf.
Text of this paper
Cambridge IGCSE™
CO-ORDINATED SCIENCES
0654/53
May/June 2023
Paper 5 Practical Test
CONFIDENTIAL INSTRUCTIONS
* 8 3 8 1 6 6 6 1 3 0 *
This document gives details of how to prepare for and administer the practical exam.
The information in this document and the identity of any materials supplied by Cambridge International
are confidential and must NOT reach candidates either directly or indirectly.
The supervisor must complete the report at the end of this document and return it with the scripts.
INSTRUCTIONS
●
If you have any queries regarding these confidential instructions, contact Cambridge International
stating the centre number, the syllabus and component number and the nature of the query.
email
[email protected]
phone
+44 1223 553554
This document has 12 pages. Any blank pages are indicated.
DC (PQ) 314685/2
© UCLES 2023
[Turn over
2
General information about practical exams
Centres must follow the guidance on science practical exams given in the Cambridge Handbook.
Safety
Supervisors must follow national and local regulations relating to safety and first aid.
Only those procedures described in the question paper should be attempted.
Supervisors must inform candidates that materials and apparatus used in the exam should be treated
with caution. Suitable eye protection should be used where necessary.
The following hazard codes are used in these confidential instructions, where relevant:
C
HH
F
N
corrosive
health hazard
flammable
hazardous to the aquatic environment
MH
T
O
moderate hazard
acutely toxic
oxidising
Hazard data sheets relating to substances used in this exam should be available from your chemical
supplier.
Before the exam
●
●
●
The packets containing the question papers must not be opened before the exam.
It is assumed that standard school laboratory facilities, as indicated in the Guide to Planning
Practical Science, will be available.
Spare materials and apparatus for the tasks set must be available for candidates, if required.
During the exam
●
●
●
●
It must be made clear to candidates at the start of the exam that they may request spare materials
and apparatus for the tasks set.
Where specified, the supervisor must perform the experiments and record the results as instructed.
This must be done out of sight of the candidates, using the same materials and apparatus as the
candidates.
Any assistance provided to candidates must be recorded in the supervisor’s report.
If any materials or apparatus need to be replaced, for example, in the event of breakage or loss,
this must be recorded in the supervisor’s report.
After the exam
●
●
The supervisor must complete a report for each practical session held and each laboratory used.
Each packet of scripts returned to Cambridge International must contain the following items:
–
the scripts of the candidates specified on the bar code label provided
–
the supervisor’s results relevant to these candidates
–
the supervisor’s reports relevant to these candidates
–
seating plans for each practical session, referring to each candidate by candidate number
–
the attendance register.
© UCLES 2023
0654/53/CI/M/J/23
3
Specific information for this practical exam
During the exam, the supervisor (not the invigilator) must do the experiments in Questions 1, 2, 3,
4 and 5 and record the results on a spare copy of the question paper, clearly labelled ‘supervisor’s
results’.
Question 1
Each candidate should be provided with:
hazard
materials and apparatus
quantity per
candidate
insect pollinated flower, radially symmetrical with between 4 and 6
petals of approximately 4 to 10 cm, large enough to see the petals,
carpel and stamen easily (e.g. a lily or tulip or a suitable local
alternative) (see note 1)
1
white tile
1
30 cm ruler graduated in mm
1
Notes
1.
When the student removes 3 petals, the internal parts of the flower should be visible.
© UCLES 2023
0654/53/CI/M/J/23
[Turn over
4
Question 2
Each candidate should be provided with:
hazard
materials and apparatus
quantity per
candidate
milk in a small beaker, labelled milk (see note 1)
10 cm3
[MH][HH][C]
4% protease solution in a small beaker, labelled 4% enzyme solution
(see note 2)
10 cm3
[MH][HH][C]
2% protease solution in a small beaker, labelled 2% enzyme solution
(see note 2)
10 cm3
[MH][HH][C]
1% protease solution in a small beaker, labelled 1% enzyme solution
(see note 2)
10 cm3
test-tubes (approximately 125 mm × 16 mm) and a means to support
them
3
5 cm3 syringes
4
glass stirring rod
1
stop-watch
1
access to means of labelling glassware
paper towels
3
Notes
1.
Milk to be made as a 2% solution from powdered skimmed milk with a protein content of around
35%, not fresh milk. Use 2 g of powdered milk for every 100 cm3 of distilled water.
2.
Powdered protease enzyme e.g. pepsin / trypsin, can be made up to a 4% solution. Use 4 g of
powdered enzyme for every 100 cm3 of distilled water.
Prior to the exam, the supervisor should test that when equal volumes of milk and 4% enzyme are
mixed at room temperature, the milk should clear in about 1 minute. The enzyme concentration
may be adjusted accordingly. Candidates must not be made aware of any changes to the enzyme
concentration.
The 2% enzyme solution is made by mixing 50 cm3 of 4% enzyme solution and 50 cm3 of distilled
water.
The 1% enzyme solution is made by mixing 25 cm3 of 4% enzyme solution and 75 cm3 of distilled
water.
The small beakers can be substituted for similar containers, but these must allow access with the
5 cm3 syringes.
Gloves should be available to candidates who are sensitive to enzymes.
© UCLES 2023
0654/53/CI/M/J/23
5
Question 3
Each candidate should be provided with:
hazard
[HH]
quantity per
candidate
materials and apparatus
0.1 mol dm–3 potassium peroxodisulfate, K2S2O8, labelled K
(see note 1)
approx.
80 cm3
mixture containing equal volumes of 0.3 mol dm–3 potassium iodide, KI,
and 0.006 mol dm–3 sodium thiosulfate, Na2S2O3, labelled H
(see note 2)
approx.
50 cm3
distilled water, labelled distilled water
approx.
40 cm3
1% starch solution supplied with a dropper and labelled starch
solution
approx.
10 cm3
10 cm3 syringe, labelled K
1
10 cm3 syringe, labelled H
1
10 cm3 syringe, labelled W
1
conical flasks (see note 3)
5
stop-watch
1
white tile
1
paper towels
3
Notes
1.
This solution needs to be made no earlier than the day before the examination.
2.
Once prepared, this solution should not be in the light.
3.
A smaller number of conical flasks can be used, the minimum being one. Candidates will need to
be advised to wash the flasks thoroughly between experiments.
4.
Solution H, distilled water and starch solution are placed in a conical flask. When solution K is
added, the time of the fastest reaction should be measurable, and the slowest reaction should be
no more than 3 minutes. Concentrations may be adjusted to achieve this.
© UCLES 2023
volume of
solution H / cm3
volume of distilled
water / cm3
drops of starch
solution
volume of
solution K / cm3
2
8
5
10
4
6
5
10
6
4
5
10
8
2
5
10
10
0
5
10
0654/53/CI/M/J/23
[Turn over
6
Question 4
Each candidate should be provided with:
hazard
[MH] [C] [N]
materials and apparatus
quantity per
candidate
0.5 mol dm–3 zinc chloride supplied in a beaker, labelled L
approx.
25 cm3
0.5 mol dm–3 sodium iodide, labelled M
approx.
5 cm3
access to 0.5 mol dm–3 ammonia solution with a dropping pipette,
labelled aqueous ammonia
[MH]
access to 0.4 mol dm–3 sodium hydroxide solution with a dropping
pipette, labelled aqueous sodium hydroxide
[MH]
access to 1.0 mol dm–3 nitric acid, labelled nitric acid
access to 0.5 mol dm–3 barium nitrate, labelled aqueous barium
nitrate
[MH][N]
© UCLES 2023
access to 0.1 mol dm–3 silver nitrate, labelled aqueous silver nitrate
test-tubes (approximately 125 mm × 16 mm) and a means to support
them
5
paper towels
3
0654/53/CI/M/J/23
7
Question 5
Each candidate should be provided with:
hazard
materials and apparatus
quantity per
candidate
piece of plasticine (modelling clay) of mass approximately 100 g
(see note 1)
1
30 cm ruler with a millimetre scale
1
100 cm3 measuring cylinder
1
piece of cotton or thread (see note 2)
1
250 cm3 beaker containing approximately 100 cm3 of cold water
1
access to a balance capable of measuring mass to 1 g
paper towels
3
rectangular blocks of wood (see note 3)
2
Notes
1.
The plasticine must be moulded into an approximate cubical shape. Use a plasticine or modelling
clay which does not break up in water.
2.
The cotton or thread must be long enough for candidates to be able to lower a piece of the
plasticine into the measuring cylinder.
3.
The dimensions of the blocks are not important, as long as they are at least 10 cm long × 4 cm
high. The wooden blocks must have smooth, straight sides.
Action at changeover
Mould the two pieces of plasticine back into a single approximate cubical shape.
Question 6
No apparatus or materials are required for Question 6.
© UCLES 2023
0654/53/CI/M/J/23
[Turn over
8
BLANK PAGE
© UCLES 2023
0654/53/CI/M/J/23
9
BLANK PAGE
© UCLES 2023
0654/53/CI/M/J/23
[Turn over
10
BLANK PAGE
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
Local Examinations Syndicate (UCLES), which is a department of the University of Cambridge.
© UCLES 2023
0654/53/CI/M/J/23
11
Supervisor’s report
Syllabus and component number
/
Centre number
Centre name
Time of the practical session
Laboratory name/number
Give details of any difficulties experienced by the centre or by candidates (include the relevant
candidate names and candidate numbers).
You must include:
● any difficulties experienced by the centre in the preparation of materials
● any difficulties experienced by candidates, e.g. due to faulty materials or apparatus
● any specific assistance given to candidates.
© UCLES 2023
0654/53/CI/M/J/23
[Turn over
12
Declaration
1 Each packet that I am returning to Cambridge International contains all of the following items:
● the scripts of the candidates specified on the bar code label provided
● the supervisor’s results relevant to these candidates
● the supervisor’s reports relevant to these candidates
● seating plans for each practical session, referring to each candidate by candidate number
● the attendance register.
2 Where the practical exam has taken place in more than one practical session, I have clearly
labelled the supervisor’s results, supervisor’s reports and seating plans with the time and laboratory
name/number for each practical session.
3 I have included details of difficulties relating to each practical session experienced by the centre or
by candidates.
4 I have reported any other adverse circumstances affecting candidates, e.g. illness, bereavement or
temporary injury, directly to Cambridge International on a special consideration form.
Signed (supervisor)
Name (in block capitals)
© UCLES 2023
0654/53/CI/M/J/23